A study on the design of tunnel lining insulation based on measurement of temperature in tunnel  

Kim, Dea-Young (현대건설 연구개발본부)
Lee, Hong-Sung (현대건설 연구개발본부)
Sim, Bo-Kyoung (현대건설 연구개발본부)
Publication Information
Journal of Korean Tunnelling and Underground Space Association / v.13, no.4, 2011 , pp. 319-345 More about this Journal
Abstract
In case of tunnels in cold regions, a freeze of groundwater around tunnel may act as a barrier of tunnel drainage in winter, or may cause the inner extrusion of lining. In spite of that, a design of insulation for preventing the frost damage of tunnel lining has not been introduced in Korea, while foreign countries such as Norway and so on have a standard on insulation. In this study, a few freezing cases of road tunnels have been reviewed, and the results show that the freezing protection is necessary. In order to characterize the thermal distribution in the tunnel, following measurements have been performed at Hwa-ak tunnel; the temperature distribution by longitudinal lengths, the internal temperature of lining and the temperature distribution of the ground under pavement. From these measurements, the characteristics of the tunnel's internal temperature distribution due to temperature change in the air has been analyzed. Based on the measurement results on the temperature distribution at Hwa-ak tunnel, thermal flow tests on the rock specimen with and without insulation have been performed in the artificial climate chamber to investigate the performance of the insulation. Also, a number of 3D numerical analyses have been performed to propose appropriate insulation and insulation thicknesses for different conditions, which could prevent the frost damage of tunnel lining. As a result of the numerical analysis, air freezing index of 291$^{\circ}C{\cdot}$ Hr has been suggested as the threshold value for freezing criteria of groundwater behind the tunnel lining.
Keywords
Frost damege of tunnel lining; thermal insulating material; thermal flow analysis; thermal flow test; insulation design in tunnel; air freezing index;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 건설교통부(2007), 남북한지역 전국 동결지수선도.
2 김대영(2005a), "국내터널 단열설계의 필요성-대관령 1터널 사례를 중심으로" 현대건설 창립기념 기술세미나 논문집.
3 김대영(2008), "터널배면 지하수 동결방지 대책에 대한 연구", 현대건설 창립기념 기술세미나 논문집.
4 김대영, 이영남(2005b), "라이닝 동상방지대책", 대한토목학회 가을 학술발표회 논문집, pp. 3674-3677.
5 석진호, 권승, 김선홍, 부성민(2006), "기존터널 확대굴착시 기 발생된 과대 여굴부에 대한 보강 방안 시공사례", 대한토목학회 터널분과위원회 학술대회 논문집, pp. 185-199.
6 정수일(2003), "측정자료가 없는 지역의 지중온도 예측방법에 관한 연구", 한국태양에너지학회 논문집, Vol. 23, No. 2, pp. 1-7.
7 Physibel (2002), RADCON manual, Belgium.
8 한국도로공사 도로교통연구원 (2005), 터널 배수시설 결빙 방지 방안 검토.
9 Broch, E., Grov, E., Davik, K.I. (2002), "The inner lining system in norwegian traffic tunnels", Tunnelling and Underground Space Technology, Vol. 17, No. 3, pp. 305-314.   DOI   ScienceOn