• Title/Summary/Keyword: Insulating paper

Search Result 489, Processing Time 0.042 seconds

The dependence of edge effect on film thickness in thin insulating films (얇은 절연막에서의 단부효과에 관한 막두께 의존성)

  • Chu, K.S.;Jo, T.H.;Joo, Y.J.;Lee, K.Y.;Sung, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1445-1447
    • /
    • 1994
  • This paper deals with the edge effect in thin insulating films, focusing on their dependence on film thickness, so we derived a simple mathematical form which depicts that reducing film thickness lowers the field at the electrode edge. we expect that this result may be suitable to problems with multi level insulating films.

  • PDF

The Study on the Electric Potential Variation of Needle Electrodes by Charged Insulating Oil in the Charge Reducer (대전된 절연유에 의한 제전관내 침전극의 전위변화에 관한 연구)

  • Kim, Y.I.;Kim, Y.B.;Kim, D.S.;Park, J.Y.;Cho, Y.K.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1583-1585
    • /
    • 1994
  • In this paper, we investigated the relationship between the needle electrode current and the needle electrode potential, The needle electrode potentials have influence on the needle electrode currents absolutely. So, to increase the needle electrode currents there is necessary to keep a high electric field if the charge reducer. for this, high insulation materials must be selected, and charge density of insulating oil must be high. In this experiment, the more a charge density of insulating oil increases, the more a needle electrode potential increases. So we could know what increasement of needle electrode potential increases a needle electrode current.

  • PDF

A Study on the Age Degradation Kinetics of Pole Transformer Oil (주상변압기 절연유의 경년열화반응 속도론에 관한 연구)

  • 남영우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.99-105
    • /
    • 1997
  • In the paper, aging of insulating oil in pole transformer has been studied by performing accelerated thermal aging test. Dissolved gases were extracted by air bubbling method. Concentration of dissolved gases were modified by extraction ratio of each gases in insulating oil. Aging of insulating materials were proceeded by thermal degradation and oxidation reaction. Both of the reactions followed zeroch order kinetics. Formation rate equations for hydrocarbons, carbon oxides, and hydrogen were derived. It was conformed by gas analysis and UV-Visible spectrophotometric method that iron core and copper coil in pole transformer act as catalyst during the aging process.

  • PDF

Temperature Characteristic Analysis according to Variation of Properties of Transformer Insulating Oil (변압기 절연유의 물성치 변화에 따른 온도특성해석)

  • Kim, Ji-Ho;Rhee, Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.327-332
    • /
    • 2014
  • In this paper, the temperature distribution according to the property change of the insulating oil of the power transformer and max temperature were predicted through the ductility interpretation which heat-flow is coupled. By using CFD (Computation Fluid Dynamics) for the interpretation, the temperature distribution of 154kV the class single phase power transformer was predicted. The power loss causing the temperature rise of the transformer was changed to the heat source and we used as the input value for the heat-flow analysis. The temperature distribution was predicted according to the change of the density, specific heat, thermal conductivity and viscosity, that is the ingredient having an effect on the temperature rise of the transformer oil. The mineral oil of 4 kinds used in domestic and international based on the interpreted result was selected and the temperature distribution according to each load and Hot Spot temperature was predicted.

A Study on Partial Discharge Location in Insulating Oil using Optical Fiber Sensors (광섬유 센서를 이용한 절연유내의 부분방전 위치검출에 관한 연구)

  • 권태호;이종길;이준호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.838-841
    • /
    • 2003
  • This paper shows results on the application of optical fiber sensors(OFS) for locations of ultrasonic signals in silicon insulating oil. The OFS system based on the principle of Sagnac interferometry has been designed and established for this work. The hollowed cylindrical mandrel wound by single mode optical fiber was used as a sensing component and ultrasonic signals which simulate the partial discharge In the oil have been generated by PZT actuator operated with function generator. The experimental results shows that the OFS has a excellent performance for the PD location with resolutions less than 1$^{\circ}C$ error range in the miniature insulating oil tank.

Dynamic Test method to Determine Modulus of Elasticity of Sound Insulating Coat (현장 타설용 고분자 감쇠재의 탄성 계수를 측정하기 위한 실험 기법)

  • Yemam, Dinberu Molla;Yi, Chongku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.92-93
    • /
    • 2015
  • The main purpose of this paper is to present the dynamic test method developed for measuring the elastic modulus of sound insulating coat. The test setup was devised based on the theoretical natural frequency of a simply-supported beam subject to free transverse vibration. A stainless steel beam was tested and the result showed a good compliance with the standard value listed in literatures. The result indicates that the test set up can serve as a quick, economical and suitable scheme to test non self-supporting materials.

  • PDF

A study on the effect of solid materials on the streaming electrification of insulating oil (절연유의 유동대전에 미치는 고체재질의 영향에 관한 연구)

  • 김용운;임헌찬;김영일;김영봉;이덕출
    • Electrical & Electronic Materials
    • /
    • v.7 no.3
    • /
    • pp.236-242
    • /
    • 1994
  • In this paper, the streaming electrification characteristics of insulating oil were examined when the oil is contacted with solid materials in a circulating system. The streaming current($I_s$) increases with increasing oil velocity and temperature, and electrification properties depend on species of metal materials. $I_s$ in the gauze-contained electrification apparatus increases with increasing oil temperature below the temperature of 43[>$^{\circ}C$], but decreases above 43[>$^{\circ}C$]. On the other hand, $I_s$ is positive electrificated for the pipe of Fe, Cu, while it is negative electrificated for Sus. When insulating oil flows through a car fuel filter, $I_s$ increases linearly with increasing oil temperature.

  • PDF

Development of the Program for Estimation Lifetime of Insulating Materials (절연재료 수명평가용 프로그램 개발)

  • Park, Sung-Min;Bae, Duk-Kweon;Lee, Sung-Il;Oh, Jae-Han;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.46-49
    • /
    • 2000
  • This paper studied development of the program for estimation the life time of insullating materials and the longtime breakdown voltage. First, short-time breakdown voltage of Epoxy and insulating oil was measured. Life exponent was gained from measurement of insulating breakdown time of the specimens. Life time is presumed from program. The estimation program is based on the "Inverse Power Law", defined $V^nt$ is constant. After gaining the life exponent n, it is mapping the longtime breakdown voltages. On the base of life exponent, the estimation the lifetime and usefulness of the insulation systems are possible, furthermore easy calculation is possible.

  • PDF

Development of Capacitive Sensor for the Diagnosis of Electrical Insulating Oil (전기절연유의 열화진단을 위한 정전용량 센서개발)

  • Choi, N.H.;Kim, H.J.;Kim, J.H.;Kim, H.S.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1609-1611
    • /
    • 2003
  • This paper presents the results on the development of capacitive sensor for the diagnosis of electrical insulating oil, widely used for power transformer. To survey the dielectric properties of the new and used mineral insulating oil, we utilized the highly precise measuring system of KRISS. And the results were used to determine the design factors of the sensor. To evaluate the operational and the hysteresis characteristics of the sensor, we constructed a test chamber, including dielectric property measuring system. Through the results we could confirm the superior characteristics of the newly developed sensor.

  • PDF

The study on the improvement of MOF insulating cover (MOF용 절연커버의 성능개선에 관한 연구)

  • Han, Ki-Boong;Lee, Dae-Jong;Han, Woon-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1753-1755
    • /
    • 2003
  • MOF insulating cover used in 22.9 kV substation hasn't shown good performance in terms of electrical safety because of its defect by short clearance MOF cover and each input and output wire junction part. The MOF cover is easily moved by outside environment as wind or rain weather because of different size MOF cover and insulating busing, also can be leaded to breakdown by tracking. Therefore, we propose MOF cover which effectively prevents from electrical accidents in this paper. To decrease the electric field concentrated on specific part, we roundly design the shape of MOF cover and clearance between cover and live part was adjusted to be longer than before. The proposed MOF cover is evaluated by using the electric field solution program.

  • PDF