• 제목/요약/키워드: Insulating paper

검색결과 490건 처리시간 0.024초

적층단열재의 열침입량 측정 (Measurement of Heat Leak through Multi-Layer Insulation)

  • 김동락;양형석;정원묵;이병섭;신필권;황시돌
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.39-42
    • /
    • 2005
  • In this paper, the thermal characteristics of multilayer insulation (MLI) were experimentally investigated by using boil-off calorimetry method for seeking optimum standards of thermal insulation conditions. It is necessary to design the thermal insulating efficiency for applying to cryogenic instruments such as HTS power cable system. It is well known that the thermal characteristics and heat transfer of MLI are greatly affected by various MLI structures such as the number of layers and layer density, etc. However, it is difficult to know the thermal characteristics of MLI correctly. The heat leak by MLI between room temperature and liquid nitrogen temperature was measured at various conditions using a cylindrical cryostat. The cryostat consists of two guard vessels located at both end sides and a test vessel between them. The guard vessels are also filled with liquid nitrogen to prevent radiation heat leak through the both end side of the cylindrical test vessel to measure the heat leak only through MLI.

E종 절연 유도 전동기의 설계 (Design of Class E Insulation Induction Motor)

  • 이승원
    • 전기의세계
    • /
    • 제16권2호
    • /
    • pp.1-8
    • /
    • 1967
  • From the discovery of Alago's disk, a number of trials and efforts have been concentrated on a small-sized and light-weighted induction motor. They have devoted themseleves, however, mainly to a improvement of cooling effect, a proper weight-distribution of copper and iron and desirable number of slots. In consequence, such an effort restricted only to the field of design, has resulted in unsatisfactory developments in the insulating materials consisting of the main parts of an induction motor. The quality of fibre and paper which are used as class-A insulation materials with their "compound" and "varnish" has been increased to some extent. Similarly Class-B insulation materials like asbest mica has been almost a combination of inorganic and binding materials. But nowadays synthesic chemistry is making a remarkable progress. So it comes possible for us to have silicon resin and other good ones of similar charateristics. And even a thin silicon resin insures us to get excellent heat-pro f and insulation, so a better space factor and cost-down in motor design have come possible in most advanced nations of the world, but not in our country. Furthermore, a consideration of productivity and economy in manufacturing process has been neglected by a majority of engineers. This is more unpleasant und more undesirable. I think this rational method of induction motor design using new synthesic resin will devote in making your productivity and economy better. And the nation-wide standard value of electric motor size is sited here. size is sited here.

  • PDF

와전류센서를 이용한 ACSR 전선의 내부부식 검출 (ACSR Inner Corrosion Detection by Eddy Current Sensor)

  • 강연욱;강지원;양병모;정재기
    • 조명전기설비학회논문지
    • /
    • 제12권1호
    • /
    • pp.12-19
    • /
    • 1998
  • 본 논문에서는 와전류센서를 장착하고 전선위를 자동으로 주행하도록 설계된 부식 검출장치를 이용하여 ACSR의 내부부식 검출에 대해서 다룬다. 또한 내부부식의 검출은 비파괴검사로 행해진다. 독특한 ACSR의 구조에 의한 부식현상을 와전류센서를 이용하여 검출하는 경우, 부식은 센서의 임피던스변화로 검출되고 이 현상을 이론적으로 증명한다. 또한 설계된 부식검출장치의 사양과 성능 그리고 실험방법에 대해 논하고, 현장에 적용가능한 실험결과를 얻었다. 이 부식검출장치는 ACSR의 내부부식을 비파괴로 검출할 수 있고 현실적이라는 결론을 얻었다. 피시험체인 도체의 피복여부에 관계없이 이장치는 이용가능하고, 이 장치의 실용화에 의해 선로의 유지보수의 효율을 증대시키고 선로의 향상이 기대된다.

  • PDF

전력기기 열화 진단을 위한 부분방전 모의 및 측정 알고리즘 개발연구 (Investigation of Simulation and Measuring Algorithm of Partial Discharge for Diagnosis of Electric Machinery Deterioration)

  • 장형택;곽선근;신판석;김창업;정교범
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.30-38
    • /
    • 2011
  • This paper proposes a new intelligent diagnosis equipment for the partial discharge, which keeps deteriorating the insulating materials inside electric machineries, ultimately leading to electrical breakdown. In order to simulate experimentally the partial discharge inside the electric machinery, the tip-to-plate, the sphere-to-plate, the sphere-to-sphere and the plate-to-plate electrodes are used respectively, of which the gaps are 1[mm], 3[mm] or 5[mm] and the applied voltages are 3[kV], 5[kV] or 7[kV]. Ceramic coupler sensor and FIR digital filter are used to measure the partial discharge and the artificial neural network is used for the deterioration diagnosis of the electric machinery. The microprocessor of PD diagnosis equipment is DSP (TMS320C6713) with FPGA (Cyclone II). The results of the real-time and on-line experiments performed with the developed equipment are also explained.

난연성 폴리 올레핀 케이블 절연재료의 내화특성 (Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant)

  • 윤헌주;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analysed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC [600] wire. Measurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflamining pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds generated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5${\pm}$0.04[w/$\textrm{cm}^2$] for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 7.2 to 77.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomp1ete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

광유의 절연파괴에 미치는 전극간격 및 침전극 곡률반경의 영향 (The Effects of Gap Length and Tip Radius Influenced in Breakdown of Mineral Based Insulating Oil)

  • 이종섭;신태수;이운용;박영국;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.254-257
    • /
    • 1997
  • In this paper, we investigated the effects of gap length and tip radius influenced in breakdown of mineral based insulation oil Electrode system was needle-plane geometry It is to model conductive extrusions in oil filled electrical power apparatus. The tip radius of needle electrode was 5, 10, 20 and 25${\mu}{\textrm}{m}$, respectively. We measured breakdown voltage for each of tip radius with increasing electrode gap, 2mm to 12mm. It was calculated electrical breakdown strength at tip using Mason\`s equation from breakdown voltage As gap lenght increased. breakdown strength increased linearly. But, as tip radius of needle increased, breakdown strength decreased exponentially. It can be explained by tole phenomenon that electron is easily injected, as tip radius increases, and effective work function decreases. When appling DC voltage. breakdown 7tr7ilgtll was higher wheal polarity of needle was negative than positive. It is because of the space charge effect ill accordance with the influence of liquid motion.

  • PDF

고차구조 변화에 따른 저밀도 폴리에틸렌의 공간전하 측정 (Space Charge Measurement of Low Density Polyethylene Film due to Morphological Change)

  • 고시현;김성필;신종렬;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.41-45
    • /
    • 2000
  • As LDPE, widely used as a insulating material of power cable, has defects of treeing and space charge accumulation, various methods to improve them have been suggested. It is difficult to understand the mechanism of electrical conduction according to the complexity of molecular structure and the changes of super-structure due to various environmental parameters. Therfore in this paper, four kinds of heat-treated LDPEs(origin, slow cooled, water cooled, quenched in $LN_2$) were used as specimens to help us understand the mechanisms and space charge distributions were investigated at 60[min] just after applying the field of 1[MV/cm] and 10[min] just after short-circuiting, using LIPP method.

  • PDF

절연체의 내아크성 평가를 위한 안테나 기법의 적용에 관한 연구 (Study on the application of antenna method for the criterion test of insulator arc resistance)

  • 이강원;김명룡;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.57-60
    • /
    • 2004
  • Electrical arc is the final stage of insulation breakdown and has high current density which cause heat and light in insulator. Insulator under electrical arc lost its insulating strength and eternal damages. Conventional criterion of electrical arc resistance in Standards have depended on the change of sound pressure and light color after damages on insulator by electrical arc. The recognition of these changes is done by human himself which was very subjective and resulted in some error to judge whether insulator has damages or not. This paper has shown that antenna method is the appropriate measure to judge electrical arc resistance for insulator. Antenna measures the electromagnetic waves radiated from tungsten electrodes with 6mm gap regulated by KSC2130. Applied voltage cross two tungsten electrodes have two different methods such as 1/8 10 and continuous 10mA. Signal amplitudes obtained by antenna has diminished after the damage of insulator, which will provide objective and good way to judge the electrical arc resistance.

  • PDF

지중 전력케이블용 절연재료의 열적 특성 및 기계적 특성 (Thermal and Mechanical Properties of Insulation Materials for Underground Power Cable)

  • 이경용;이관우;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.138-141
    • /
    • 2004
  • In this paper, we Investigated effects on impurities and water of semiconductive shield through a thermal, mechanical, and absorption experiment to estimate performance of insulating materials in power cable. Specimens had been prepared 22[kV], 154[kV] XLPE power cables and then were made of sheet form with XLPE and semiconductive shield with dimension of 0.4[mm] ~1.2[mm] of thickness from power cable. Heat capacity $({\Delta}H)$ and glass trasition temperature (Tg) of XLPE sheet were measured by DSC (Differential Scanning Calorimetry). We could know that thermal stabilities of 154[kV] are more excellent than 22[kV] from this experimental result. The strain of mechanical properties in 22[kV] and 154[kV] XLPE was 486[%], 507[%] and stress was 1.74$[kgf/mm^2]$, 1.80$[kgf/mm^2]$. The absorption contents of existing semiconductive shield were measured 710[ppm] to 1,090[ppm], and semiconductive shield of 22[kV] cable was measured 14,750[ppm] to 24,780[ppm]. We thermal and mechanical properties of 154[kV] could know more excellent than 22[kV] from this experimental result.

  • PDF

전력케이블용 가교 폴리에칠렌과 반도재료의 전기적 특성 (Electrical Characteristics of XLPE/Semicinductor Sheet for Power Cables)

  • 백광현;이경용;이관우;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.142-145
    • /
    • 2004
  • In this paper, we researched the dielectric properties and voltage dependence on slice XLPE sheet from 22[kV] and 154[kV] power cable. studied effect for impurities and water for semiconductive shied through a dielectric properties experiment to estimate performance of insulating material in power cable. Capacitance and $tan{\delta}$ of 22[kV], 154[kV] were 52/42 pF and $7.4{\times}10^{-4}$, $2.1510^{-4}$, respectively. In these results, the trend was increased with the increase of temperature. The $tan{\delta}$ of XLPE/semiconductive layer and XLPE/water/semiconductive layer were increased as compared with that of XLPE. dielectric properties reliability of $tan{\delta}$ was small.

  • PDF