• Title/Summary/Keyword: Instrumentation device

Search Result 168, Processing Time 0.022 seconds

Design Optimization of Silicon-based Junctionless Fin-type Field-Effect Transistors for Low Standby Power Technology

  • Seo, Jae Hwa;Yuan, Heng;Kang, In Man
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1497-1502
    • /
    • 2013
  • Recently, the junctionless (JL) transistors realized by a single-type doping process have attracted attention instead of the conventional metal-oxide-semiconductor field-effect transistors (MOSFET). The JL transistor can overcome MOSFET's problems such as the thermal budget and short-channel effect. Thus, the JL transistor is considered as great alternative device for a next generation low standby power silicon system. In this paper, the JL FinFET was simulated with a three dimensional (3D) technology computer-aided design (TCAD) simulator and optimized for DC characteristics according to device dimension and doping concentration. The design variables were the fin width ($W_{fin}$), fin height ($H_{fin}$), and doping concentration ($D_{ch}$). After the optimization of DC characteristics, RF characteristics of JL FinFET were also extracted.

Design and Implementation of CMS Based on MDEC for Biological Instrumentation (생체 계측을 위한 MDEC 기반의 CMS 설계 및 구현)

  • Jung, Hyon-Chel;Kim, Tea-Koon;Jun, Jea-Hoon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.07a
    • /
    • pp.101-102
    • /
    • 2015
  • 본 논문에서는 다수의 생체계측 정보를 MDEC(Medical Device Exchange Communication) 기반의 공통모듈을 이용하여 중앙 집중 관리를 위한 CMS(Central Monitoring System)를 제안한다. 기존의 바이탈사인 모니터 등은 환자별로 부착되어 다수의 환자에 대한 이상 징후를 실시간으로 모니터링하기에는 어려움이 있다. 이에 본 논문에서는 다수의 계측 장비를 통합하는 공통모듈인 MDEC을 이용하여 집중 모니터링이 가능한 CMS을 구현하였다. 계측장비와 MDEC의 패킷 송수신을 위한 프로토콜을 설계하고 네트워크로 전송된 패킷은 CMS에 표시되며 데이터베이스에 저장된다. 본 연구의 결과는 급속히 증가하는 병원내 환자 관리 및 효율적 의료서비스에 기여할 것으로 사료된다.

  • PDF

Boost Input type High Power Factor Resonant Power Supply for driving Magnetron Device (마그네트론 구동용 고역률 부스트 입력 방식의 공진형 전원장치)

  • Jeong, Jin-Beom;Yeon, Jae-Eui;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1078-1080
    • /
    • 2003
  • This paper proposes the boost input type resonant power supply for driving the magnetron device of the high-capacity microwave oven. Circuit topology of the proposed power supply is the boost input type resonant converter which uses the resonance between transformer leakage inductance and resonance capacitance. Proposed power supply obtains high power factor more than 98% through continuous current mode pulse width modulation. To verify the validity of the proposed power supply, operation principle in the steady state is analyzed and experimental results are presented.

  • PDF

Magnetic Sensitivity Improvement of Silicon Vertical Hall Device (Si 종형 Hall 소자의 자기감도 개선)

  • Ryu, Ji-Goo;Kim, Nam-Ho;Chung, Su-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.260-265
    • /
    • 2011
  • The silicon vertical hall devices are fabricated using a modified bipolar process. It consists of the thin p-layer at Si-$SiO_2$, interface and n-epi layer without $n^+$buried layer to improve the sensitivity and influence of interface effects. Experimental samples are a sensor type I with and type H without p+isolation dam adjacent to the center current electrode. The experimental results for both type show a more high current-related sensitivity than the former's vertical hall devices. The sensitivity of type H and type I are about 150 V/AT and 340 V/AT, respectively. This sensor's behavior can be explained by the similar J-FET model.

Application on Autonomous Things Monitoring System for IoT Platform of Smart City (스마트시티 IoT플랫폼 구축을 위한 자율사물 모니터링 시스템 적용성 평가)

  • Yoo, Chan Ho;Baek, Seung Cheol
    • Land and Housing Review
    • /
    • v.11 no.1
    • /
    • pp.103-108
    • /
    • 2020
  • Autonomous things system is a technology that judges and acts based on using surrounding information by itself, and it is evaluated as a future technology that can replace the current IoT technology. The current IoT technology is widely used from facility monitoring to machine control but it is shown weakness as a evaluation and prediction technique despite of smart city important technology. In this study, in order to confirm the application of the autonomous things technology, a monitoring system was installed on a real reservoir dam facility and long-term monitoring was performed that the measuring device itself judges and control as a facility monitoring technology. The autonomous things technology was confirmed during 19 months and it is possible to continuous measurement in the same way as current automated instrumentation. In addition, it was confirmed that the ICT device itself could to control autonomously measurement cycle according to the rainfall by itself.

A Study on Implementation of a VXIbus System Using Shared Memory Protocol (공유메모리 프로토콜을 이용한 VXIbus 시스템 구현에 관한 연구)

  • 노승환;강민호;김덕진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.9
    • /
    • pp.1332-1347
    • /
    • 1993
  • Existing instruments are composed independently according to their function and user constructed instrumentation system with those instruments. But in the late 1980s VXI bus enables to construct instrumentation system with various modular type instruments. For an VXI bus system with the word serial protocol, an increase of data size can degrade the system performance. In this paper shared memory protocol is proposed to overcome performance degradation. The shared memory protocol is analyzed using the GSPN and compared with that of the word serial protocol. It is shown that the shared memory protocol has a better performance than the word serial protocol. The VXI bus message based-system with the proposed shared memory protocol is constructed and experimented with signal generating device and FFT analyzing device. Up to 80 KHz input signal the result of FFT analysis is accurate and that result is agree with that of conventional FFT analyzer. In signal generating experiment from 100 KHz to 1.1 GHz sine wave is generated.

  • PDF

Design and Fabrication of an Automatic Alignment and Loading System for Workpieces (공작물 적재를 위한 자동정렬 및 적재장치의 설계 및 제작)

  • Lee, Jae-Kyung;Choi, Myung-Chul;Kim, Gab-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.3
    • /
    • pp.134-140
    • /
    • 2018
  • This paper describes the design and fabrication of an automatic alignment and loading system for workpieces. To move a workpiece to a chucking position of a machine tool using a gantry robot, an automatic aligning device is required to load the workpiece before machining and automatically align them. The automatic alignment system was conceptually designed, and the structural analysis was performed for the main parts such as the top plate, center support, front and back support, and support shaft. Based on the structural analysis results, the size of these structures was determined. The automatic alignment system was manufactured, and the vertical movement characteristics of the workpiece up-and-down movement device and the rotation characteristics of the workpiece rotation device were experimentally examined. The result has confirmed that they operate normally.

Development of Realtime ECG Analysis and Monitoring System (실시간 심전도 분석 및 모니터링 시스템 개발)

  • Jeong, Gu-Young;Yoon, Myoung-Jong;Yu, Kee-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.4
    • /
    • pp.406-412
    • /
    • 2009
  • ECG is used on purpose to keep good health or monitor cardiac function of aged person as well as on purpose to diagnose the disease of heart patients. The ambulatory ECG monitoring system under guarantee of safety and accuracy is very efficient to prevent the progress of heart disease and sudden death. These systems can detect the temporary change of ECG that is very significant to diagnose heart disease such as myocardial ischemia, arrhyamia and cardiac infarction. In this paper, we describe the ECG signal analysis algorithm and measurement device for ECG monitoring. The authors designed a small-size portable ECG device that consisted of instrumentation amplifier, micro-controller, filter and RF module. The device measures ECG with four electrodes on the body and detects QRS complex and ST level change in realtime. Also it transmits the measured signals to the personal computer. The developed software for ECG analysis in personal computer has the function to detect the feature points and ST level changes.

Method to Simulate the Automatic Processing of Large Aircraft Wing Ribs (대형항공기 날개 리브 가공을 위한 자동화 공정 시뮬레이션)

  • Song, Chul Ki;Lee, Dae-geon;Lee, Chang-beom;Kim, Gab-soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.9
    • /
    • pp.85-92
    • /
    • 2020
  • In this study, the automatic processing of the wing ribs of large aircraft was simulated. Specifically, in the simulation for the automatic processing of the fly ribs, the process of the automated loading device with a robot was examined, along with the wing rib processing and manufacturing automation processes. Moreover, the process time, corresponding to all the stages in the wing rib processing, was calculated. The results pertaining to the machining and manufacturing times of 34 wing ribs (Nos. 1-17), as obtained through the proposed simulation approach, indicated that the total machining time for the left and right wing ribs and rib guns was 537.7 h. The production time was calculated as 1,117.4 h. It is considered that the processing of the wing ribs of large aircraft can be automated in a factory, based on the results of the proposed simulation process.

Development of Finger-force Measuring System with Six-axis Force/moment Sensor for Measuring a Spherical-object Grasping Force (6 축 힘/모멘트센서를 이용한 구물체 잡기 손가락 힘측정장치 개발)

  • Kim, Hyeon-Min;Yoon, Joung-Won;Shin, Hee-Suk;Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.37-45
    • /
    • 2010
  • Stroke patients can't use their hands because of the paralysis of their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by grasping a spherical object. At present, the used object in hospital is only a spherical object, and can't measure the force of fingers. Therefore, doctors judge the rehabilitating extent by touching and watching at their fingers. So, the spherical object measuring system which can measure the force of their fingers should be developed. In this paper, the finger-force measuring system with a six-axis force/moment sensor which can measure the spherical-object grasping force is developed. The six-axis force/moment sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP (digital signal processing). Also, the grasping force test of men was performed using the developed finger-force measuring system, it was confirmed that the average force of men was about 120N.