• 제목/요약/키워드: Instrument transformer

검색결과 39건 처리시간 0.032초

Investigation of the effects of common and separate ground systems in wireless power transfer

  • Park, Woocheon;Moon, Jung-Ick;Cho, In-kui
    • ETRI Journal
    • /
    • 제44권2호
    • /
    • pp.339-345
    • /
    • 2022
  • This article presents an investigation of the effects on a grounding system of wireless power transfer (WPT) when transmitting over relatively far distances, that is, up to 1.25 m. Conventional two-coil WPT systems are sufficiently commercialized in strong coupling range, but it is important to accomplish the long-range WPT in weak coupling range for further various applications. This system depends on the coupling effect between the two coils that the grounds of the transmitting and receiving coils should be completely separated. However, when evaluating the performance of two-coil systems with the instrument consisting of two ports and one common ground, undesirable problems occur in weak coupling ranges, for example, obtaining disagreeable transmission efficiency and degrading system stability/reliability. We investigate the problems of the leakage power from common ground systems and provide a practical solution to obtain a reliable WPT system by using an isolation transformer. The usefulness of this approach is that it is possible to achieve the stability of the system with relatively far transmitting distances and to determine the exact transmission efficiency.

건설현장의 수전설비에서 사용되는 계기용변성기 절연커버의 성능개선에 관한 연구 (A Study on the Improvement of Insulation cover for Instrument Transformer Used In Power Receiving System of Construction Sites)

  • 길형준;최충석;김향곤;한운기;이복희
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.55-62
    • /
    • 2005
  • 건설현장의 임시전력설비는 최소한의 보호장치, 산만한 작업환경, 전기설비의 노후화 등의 불안요인에 의해 타설비에 비해 많은 감전위해요인을 나타내고 있다. 이중 22.9[kV] 수전설비에 사용되는 계기용변성기 절연커버는 절연커버와 전선 인입 및 인출부 사이의 이격거리가 짧아 전기안전 측면에서 좋은 성능을 나타내지 못하고 있다. 절연커버와 부싱 사이의 크기 차이로 바람, 비등의 외부 환경에 의해 절연커버의 유동이 쉽게 발생하며, 트래킹에 의한 절연파괴로 이어질 수 있다. 따라서 본 논문에서는 전기재해를 효과적으로 방지할 수 있는 계기용변성기 절연커버를 제안하였으며 이미 실용신안으로 등록되었다. 특정 부위의 전계 집중을 감소시키기 위해 절연커버의 형상을 곡면으로 설계하였고 절연커버와 충전부 사이의 이격거리를 기존의 방식보다 더 길어지도록 조정하였다. 제안된 절연커버는 전계해석 프로그램에 의해 평가되었다.

몰드변압기의 보이드 결함 크기 판별 (Identification of Void Diameters for Cast-Resin Transformers)

  • 정기우;김성욱
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.570-573
    • /
    • 2022
  • 본 논문에서는 신경망 모델을 적용한 몰드변압기의 보이드 결함 크기 판별에 관한 연구를 수행하였다. PCB 기반의 로고우스키 코일형 부분방전 센서를 제작하여 부분방전 신호를 측정하였고, 보이드에 의한 부분방전 결함을 모의하기 위한 PD 전극계를 제작하였다. 또한 보이드는 원통형 모양의 알루미늄 틀을 제작하여 에폭시가 경화되는 과정에서 실린지를 삽입하고 공기를 주입하여 서로다른 직경을 가지는 4개의 시편을 제작하였다. 보이드 결함 크기 판별을 위해 부분방전 전하량, 방전 펄스 수, 위상 분포의 부분방전 특성 파라미터를 추출하여 Labview 기반의 VI (Virtual Instrument)로 역전파 알고리즘을 설계하였다. 실험 결과로부터 제작된 알고리즘은 90%이상의 판별률로 결함의 직경크기를 구분할 수 있었다. 본 연구의 결과는 현장에서 PD 측정 시 몰드변압기의 유지보수 및 절연물 교체의 근거 자료로 활용될 수 있을 것으로 판단된다.

  • PDF

고압 전기설비 부분방전시험을 위한 노이즈 저감방안 (A Novel Noise Reduction Method for Measuring Partial Discharge in High Voltage Electric Machinery)

  • 이영준;박광하;최형주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2021_2022
    • /
    • 2009
  • Partial discharges(PD) is a important factor to evaluate the insulation state in high voltage electric machinery. However, measuring PD under the circumstances of power plant is occasionally impossible due to the relatively high magnitude of noise which is emanated from the operating machinery. In some case, the instrument measuring PD can not even perform a calibration that initializes tools and enhance the accuracy. This paper presents that we devised a noise reduction method and demonstrated the usefulness in acquiring reliable PD signals. We attached a series of filter and transformer at the input of power source of the instruments which refrains high noise signals from incoming to the instruments. We experimented the efficiency of noise reduction applying the device into the Dangjin Power Plant and Factory. As a result of testing with the filter and transformer, we can easily calibrate the PD signal compared to the case without the device. Additionally, we can detect the small PD signal which was unperceived with a normal device.

  • PDF

변압기 지역 코로나 전자파 간섭에 의한 계측제어설비 영향에 관한 연구 (A Study on the Effects of I&C Systems by EMI Generating from Corona Discharge at Transformer Area)

  • 민문기;이재기;박진엽;김희제
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.266-271
    • /
    • 2014
  • The Electromagnetic Interference(EMI) generating from corona discharge of transformer area can interference the digital Instrument and Control(I&C) systems located nearby transformers. When the potential gradient of the electric field around the conductor is high enough to form a conductive region but not high enough to cause electrical breakdown to nearby objects, the EMI of corona discharge emits with the conducted and radiated noise and it interferences the signals of the I&C systems. Since digital I&C systems have an efficiency and competitive price, the analog I&C systems have been upgraded and displaced with the digital I&C systems but which have less EMI Immunity. There was no assessment to I&C systems by EMI generating corona discharge nearby transformers. When the safety-related I&C systems are installed in plants, the verification of equipment EMI should be done not in site-specific test but in test facilities. There are the need to do the site-specific EMI evaluation of corona discharge nearby transformers. This paper assesses the margin between plant emission limits and the highest composite plant emission of corona. When the non safety-related I&C systems are placed in transformer area, it suggests the appropriate radiated susceptibility level to EMI of corona discharge.

154kV급 실증시험용 인텔리전트 변전소 구축 (Construction of 154kV Intelligent Substation for Verification Test)

  • 정영환;김민수;김정배;이학성;최인혁;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.456-457
    • /
    • 2006
  • We have carried out the construction of the 154kV intelligent substation with KEPRI. The Intelligent substation is built in Gochang testing facility of KEPCO and consists of electronic instruments for GIS(gas insulated switchgear), digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are introduced compared with the instrument transformer of conventional type. Digital control Panel(DCP) replaces the LCP(local control panel) which is drived for mechanical operation. For the monitoring of the condition of GIS and TR, various sensors are used. In this Paper, we mention the synopsis and report the progress state of project.

  • PDF

154kV급 인텔리전트 변전소 구축 (Construction of Intelligent Substation for 154kV Class)

  • 정영환;양대일;김정배;송원표;최인혁;김정호;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.33-35
    • /
    • 2005
  • We perform intelligent substation construction of 154kV class with KEPRI. The intelligent substation is build in Gochang 765kV testing facility and consists of electronic instruments, digital control panel, remote monitoring and diagnosis system and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are applicable for instrument transformer of conventional type. Digital control panel(DCP) replaces local panel which is drived by mechanical operation. For monitoring condition of GIS and TR, various sensors are used. In this paper, we report the synopsis and the progress state of project.

  • PDF

154kV급 인텔리전트 변전소 구축 (Construction of Intelligent Substation for 154kV Class)

  • 정영환;양대일;김정배;최인혁;김정호;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.129-130
    • /
    • 2005
  • We perform intelligent substation construction of 154kV class with KEPRI. The intelligent substation is build in Gochang 765kV testing facility and consists of electronic instruments, digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are applicable for instrument transformer of conventional type. Digital control panel(DCP) replaces local panel which is drived by mechanical operation. For monitoring rendition of GIS and TR, various sensors are used. In this paper, we report the synopsis and the progress state of project.

  • PDF

154kV 인텔리전트 변전소 구축 (Intelligent Substation Construction of 154kV Class)

  • 김정배;정영환;송원표;최인혁;김정호;이동일;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.524-526
    • /
    • 2004
  • We perform intelligent substation construction of 154kV class with KEPRI. The intelligent substation is build in Gochang 765kV testing facility and consists of electronic instruments, digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are applicable for instrument transformer of conventional type. Digital control panel(UP) replaces local panel which is drived by mechanical operation. For monitoring condition of GIS and TR, various sensors are used. In this paper, we report the synopsis and the progress state of project.

  • PDF

전자빔 가공기용 고전압 발생기의 입력 형태에 따른 제어회로의 설계 (Design of Control Circuit for Various Input Types of High Voltage Generator in E-Beam Manufacturing System)

  • 임선종;이찬홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.459-460
    • /
    • 2006
  • Electron beam manufacturing system can be used to make patterns that are smaller than can a photolithography. In this system, High voltage generator is a fundamental element for stable beam. We used high voltage with transformer. However, this instrument has several problems (for examples, dimensions, buying parts, simplicity of control circuit). For solving these problems, a commercial product is considered. This is developed for SEM(Scanning Electron Microscope). In this paper, we designed a control circuit for a commercial product and analyzed performance.

  • PDF