• Title/Summary/Keyword: Instantaneous Voltage control

Search Result 205, Processing Time 0.025 seconds

Instantaneous Control of a Single-phase PWM Converter Considering the Voltage Ripple Estimate (전압 리플 추정을 고려한 단상 PWM 컨버터의 순시치 제어)

  • 김만기;이우철;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.29-34
    • /
    • 1997
  • In this paper, instantaneous controller of a single-phase PWM converter is realized using DSP. The stable PI gain of the input current and the DC link voltage control system is designed. The DC link voltage control system can be designed in continuous- time domain. But as for the input current control system, the descretizing effect cannot be ignored so it must be designed in descrete-time domain considering the calculation time. The capacitance estimating algorithm which can be acquired through the ripple voltage is proposed. By this algorithm the DC link capacitance can be estimated even under the transient state. Experimental results show the input power factor of 99.1% and the voltage variation rate of $\pm$5% according to the load variation.

  • PDF

Instantaneous Following PWM Control of Inverter for Blower Motor (브로워용 전동기 인버터의 순시추종 PWM 제어)

  • Ra B. H.;Kwon S. K.;Lee H. W.;Chun J. H.;Kim K. T.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.275-278
    • /
    • 2003
  • Conventional vector control inverter is usually used for blower of air-accord equipment. In this paper, it is proposed that inverter is controlled by instantaneous following PWM controller. This controller compensate and follow for output voltage of inverter within one switching cycle as an error that compared output voltage of rectifier included much ripples with reference voltage of sine wave. It has not speedy response like vector controller, but the circuit is very simple as using analog integer. And it has advantages that develop input power factor, built small-capacity and low-cost because huge capacitor of voltage type inverter removed.

  • PDF

Voltage-fed high frequency resonent inverter of instantaneous current phaser control method (순시 전류 phaser 제어방식의 전압형 고주파 공진 인버터)

  • LEE K.H.;RO C.K.;KIM D.H.;LEE B.S.;PARK J.K.;JUNG B.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.348-351
    • /
    • 2001
  • In this paper, voltage-fed high frequency resonant inverter of instantaneous current phaser control method used to DC voltage source separated is proposed. In the output control method, a novel circuit type of phase shift driving signal method with CVCF illustrated, also the operation principle of the proposed circuit is described in detail and its characteristics are presented as to normalized parameters. According to the each mode, in order to the circuit analysis and characteristic evaluation of the state equation are derives and present used to normalized parameter. In the future, this proposed inverter show that it can be practically used as power source system for the lighting equipment of discharge lamp, DC-DC converter etc.

  • PDF

New control strategy of Static Inverter for the Light Rail Transit (경량전철용 보조전원장치의 새로운 제어 기법)

  • Lee, Eun-Kyu;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.190-193
    • /
    • 2003
  • This paper Proposes 40 [KVA] rated SIV(Static Inverter) system for Light Rail Transit. The SIV Provide power of a fluorescent light in the car, Air-conditioner. and other equipments. To control output voltage it is used voltage control loop for constant voltage control and simultaneously used current control loop for instantaneous control at load changing. The Performance of SIV system will be verified by experimental results.

  • PDF

A Novel Detection Algorithm for Instantaneous Voltage Sag Corrector Using Series Compensator

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.502-507
    • /
    • 2001
  • This paper proposes a novel detection algorithm of faulted voltages under the unbalanced condition. To quantify the standard of unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (MF). It is analyzed that MF and UF values are given as the dc constant values even though unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

  • PDF

Development of Static Inverter for the Light Rail Transit (경량전철용 보조전원장치의 개발)

  • 이은규;염상구;최재호
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.522-527
    • /
    • 2002
  • This paper proposes 40 [KVA] rated SW(Static Inverter) system for Light Rail Transit. The SIV provide power of a fluorescent light in the car, Air-conditioner, and other equipments. To control output voltage it is used voltage control loop for constant voltage control and simultaneously used current control loop for instantaneous control at load changing. The performance of SW system will be verified by experimental results.

  • PDF

A Study on the New Sensorless Control Algorithm for Permanent Magnet Synchronous Motor (영구자석 동기전동기의 새로운 센서리스 제어 알고리즘에 관한 연구)

  • Jun, Byoung-Ho;Choi, Yang-Kwang;Kim, Young-Seok;Han, Yoon-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.144-146
    • /
    • 2003
  • This paper presents a new speed sensorless control algorithm of a permanent magnet synchronous motor based on instantaneous reactive power. The proposed algorithm is constructed by instantaneous reactive power in the stationary reference frame and is not affected by mechanical motor parameters, because mechanical equation is not used. The effectiveness of the proposed algorithm is verified by the experimental results.

  • PDF

Instantaneous Voltage Control of Inverter for Uninterruptible Power Supply (무정전전원장치용 인버터의 순시전압제어)

  • Kim, Jae-Sik;Kim, Wan-Ki;Kim, Hyo-Sung;Park, Se-Hyun;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1055-1059
    • /
    • 1992
  • Instantaneous Voltage Control of inverter for uninterruptible power supply(UPS) is presented. In order to improve the transient response, the authors propose a control scheme based on a double regulation loop with sinusoidal hysteresis band. And also, using 8097 single chip microprocessor, software synchronization and static switch control scheme is impremented with minimal hard ware structure.

  • PDF

Control Strategy of Improved Transient Response for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Grid Unbalance (계통 불평형시 과도 응답 특성이 개선된 고압 이중여자 유도형 풍력발전 시스템의 제어 전략)

  • Han, Dae-Su;Suh, Yong-Sug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.91-103
    • /
    • 2015
  • This paper investigates control algorithms for a doubly fed induction generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage wind power system under unbalanced grid conditions. Negative sequence control algorithms to compensate for unbalanced conditions have been investigated with respect to four performance factors: fault ride-through capability, instantaneous active power pulsation, harmonic distortions, and torque pulsation. The control algorithm having zero amplitude of torque ripple indicates the most cost-effective performance in terms of torque pulsation. The least active power pulsation is produced by a control algorithm that nullifies the oscillating component of the instantaneous stator active and reactive power. A combination of these two control algorithms depending on operating requirements and depth of grid unbalance presents the most optimized performance factors under generalized unbalanced operating conditions, leading to a high-performance DFIG wind turbine system with unbalanced grid adaptive features.

A New Control Method for a Single-Phase Hybrid Active Power Filter based on a Rotating Reference Frame

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.718-725
    • /
    • 2009
  • To get instantaneous reference data in a single power system with vector space phasors, the instantaneous load current is adopted as a phase and another new signal, which is delayed through filtering by the phase-delay property of a low-pass filter, is used as the secondary phase. Because the two-phases have a different phase, the instantaneous value of the harmonic current can be obtained without a time-delay in calculation. The reference voltage is created by multiplying the coefficient k by the compensation current using the rotating reference frame synchronized with the source-frequency. To verify the validity of the proposed control method, experiments are carried out on a prototype of the single-phase hybrid active power filter system.