Browse > Article

A New Control Method for a Single-Phase Hybrid Active Power Filter based on a Rotating Reference Frame  

Kim, Jin-Sun (Dept. of Electrical and Electronics Eng., Inha University)
Kim, Young-Seok (Dept. of Electrical and Electronics Eng., Inha University)
Publication Information
Journal of Power Electronics / v.9, no.5, 2009 , pp. 718-725 More about this Journal
Abstract
To get instantaneous reference data in a single power system with vector space phasors, the instantaneous load current is adopted as a phase and another new signal, which is delayed through filtering by the phase-delay property of a low-pass filter, is used as the secondary phase. Because the two-phases have a different phase, the instantaneous value of the harmonic current can be obtained without a time-delay in calculation. The reference voltage is created by multiplying the coefficient k by the compensation current using the rotating reference frame synchronized with the source-frequency. To verify the validity of the proposed control method, experiments are carried out on a prototype of the single-phase hybrid active power filter system.
Keywords
Harmonic current; Imaginary phase; Single-phase hybrid active power filter; Instantaneous compensation; Rotating reference frames;
Citations & Related Records

Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 B. L. Lin, et. al., "Simplified control method for single-phase multilevel active rectifier with current harmonic filtering characteristics," Electr. Power Appl., IEE Proc, Vol. 1, No. 1, pp. 85-96, 1993, Jan. 2001
2 Chengyong Zhao et. al., "Simplified control method for single-phase multilevel active rectifier with current harmonic filtering characteristics," Industrial Electronics Society, IECON '01. The 27th Annual Conference of the IEEE, Vol. 2, pp. 1067-1071, Nov-Dec. 2001   DOI
3 A. Sannino et. Al., "Static series compensator for voltage sag mitigation supplying nonlinear loads," Power Engineering Society Winter Meeting, 2002. IEEE, vol.2, PP. 1147-1152, Jan. 2002
4 Bor-Ren Lin, et Al., "Control scheme of hybrid active filter for power quality improvement," Industrial Technology, IEEE ICIT '02, IEEE International Conference, Vol. 1, pp. 317-322, 2002   DOI
5 F. Pottker de Souza, et. al., "Single-phase active power filters for distributed power factor," Power Electronics Specialists Conference, PESC 00. 2000 IEEE 31st Annual, Vol. 1, PP. 500-505, Jun. 2000   DOI
6 F. Pottker et. Al., "Power factor correction of non-linear loads employing a single phase active power filter: control strategy, design methodology and experimentation," Power Electronics Specialists Conference, PESC '97 Record., 28th Annual IEEE, Vol. 1, pp. 412-417, 1997
7 B. Dobrucky et. al., "Single-phase power active filter and compensator using instantaneous reactive power method," Power Conversion Conference 2002 PCC Osaka, Vol. 1, pp. 167-171, Apri. 2002   DOI