• 제목/요약/키워드: Installed performance

검색결과 2,743건 처리시간 0.031초

항공기 공지통신 무전기 성능개량을 위한 자동 TOD 연동방안 연구 (The Study of Automatic TOD Synchronization for Air-Ground Radio Performance Improving in Legacy Aircraft)

  • 장진욱;안승범;최명석
    • 한국군사과학기술학회지
    • /
    • 제25권3호
    • /
    • pp.292-299
    • /
    • 2022
  • In this paper, we proposed an automatic TOD synchronization and verification method for improving the performance of air-to-ground radio(hereafter SATURN) of legacy aircraft. In order to automatically synchronize TOD with SATURN radio, it is proposed to modify the GPS antenna installed in the existing aircraft according to the minimum operating performance standard. In addition, test methods and results are presented to verify the TOD information generation capability before and after the GPS antenna modifying. It is expected that the automatic TOD synchronization method proposed in this paper can be applied to the SATURN performance improvement design.

터보펌프 Cavitation 성능시험기 개발 및 성능시험에 관한 연구 (Development of Turbopump Cavitation Performance Test Facility and the Test of Inducer Performance)

  • 손동기;김춘택;윤민수;차봉준;김진한;양수석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.619-624
    • /
    • 2001
  • A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar; rotational speed 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification.

  • PDF

공연무대를 이용한 엔터테인먼트 로봇의 위치추정 방법 (Position Estimation Method of Entertainment Robot in Performance Stage)

  • 강철웅;고석준
    • 대한임베디드공학회논문지
    • /
    • 제9권3호
    • /
    • pp.151-156
    • /
    • 2014
  • In this paper, we propose a position estimation method of an entertainment robot in a performance stage. A position information is needed to produce contents of an entertainment robot performance. First, the performance stage is realized by a CD (cadmium sulfide) sensor matrix with a constant distance. Then the proposed position estimation uses ON/OFF information of a CD sensor in a performance stage. We confirmed that the position of the robot is detected with an maximum 4cm in position evaluation experiments. The robot was traveling to the final target position in the walking experiment with 75cm and 120cm path plan. Ultimately, the effectiveness of the proposed estimation is assessed by experimental results of a robot in performance stage. Also, in the proposed system installed by a robot performance contents, there is no necessity to mount a position estimation device on a robot; therefore an advantage of our system is that an entertainment robot commercialized by robot vendor can be utilized in our performance stage directly.

광선반 채광시스템의 시각적 성능 평가 (Visual Performance Evaluation of Daylighting System with Sloped Lightshelves)

  • 김정태;심인보
    • KIEAE Journal
    • /
    • 제6권2호
    • /
    • pp.3-10
    • /
    • 2006
  • This study assessed the visual performance of luminous environment by the lightshelf. The subject survey method was used and results are presented and analyzed. The lightshelf daylighting system was developed by LAEL at KH University and was applied on the window of a mock-up office. The questionnaire for assessing visual performance contains 9 questions with 7 grade bipolar scales. The experiment was conducted during the bright part of the day from noon to one thirty on June 7, 2006. The questionnaire for assessing visual performance contains 9 questions with 7 grade bipolar scales. During the experiment was carrying out, the work plane illuminance and luminous distribution at surrounding the windows was measured. The semantic differential rating data of experiment were analyzed by t-test and factor analysis using SPSS 12.0 statistics package. The visual performance of the lightshelf was more positive. The factors affecting the visual performance are task performance and visual comfort. The subjects were more comfortable in a room installed with lightshelves on both the task performance and the visual comfort aspect. Therefore, the application of sloped lightshelf daylighting system improves visual performance of luminous environment.

GIS용 피뢰기 누설전류 측정장치 성능개선 (The Performance Improvement of Lightning Arrester Leakage Current Measuring Device for GIS)

  • 김원규;김민수;백영식
    • 전기학회논문지
    • /
    • 제63권12호
    • /
    • pp.1726-1731
    • /
    • 2014
  • This paper shows the developed new lightning arrester LCM (Leakage Current Measuring device) which is important element of GIS (Gas Insulated Switchgear) Preventive & Diagnostic system and verify its performance though strengthened test standards. The existing lightning arrester LCM was modified to solve measuring errors which happened frequently. At first, we explained the principle of measuring leakage current. Through analyzing some problems which the existing LCM have. we got some improvable items. For the performance verification of the improved LCM, we manufactured prototype LCM which is applied some improvable items such as improving LCM circuit, adding protection circuit, optimizing inner structure of LCM and changing ground design. After then we carried out the performance test. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria. Also, we confirmed the performance of the improved LCM installed & being operated at G Substation through the immunity test against the normal noise and open/close surge etc.

부유식 파력발전구조물의 운동 저감부 형상설계에 관한 수치 및 실험적 연구 (Experimental and Numerical Study for Motion Reduction Design of Floating Wave Energy Converter)

  • 박지용;남보우;홍사영;신승호
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제17권2호
    • /
    • pp.81-89
    • /
    • 2014
  • 부유식 파력발전구조물의 운동은 발전성능과 구조물의 안정성에 중요한 영향을 미치며, 이에 구조물의 형상 최적화가 필요하다. 본 연구에서는 기존에 연구되고 있는 부유식 진자형 파력발전장치를 대상으로 운동 저감부 형상의 부가를 통해 운동응답특성을 최적화 하려 한다. 이를 위해 감쇠판을 설치하여 부가저항과 감쇠력을 변화시키고, 복원판을 설치하여 복원력을 증가시켜 구조물의 운동응답의 변화를 확인하였다. 실험을 통해 운동응답특성의 변화를 비교 검증하였으며, 수치해석을 통해 다양한 운동저감부 형상에 대해 분석하였다. 본 연구를 통해 부유식 파력발전구조물의 형상을 최적화하고 성능을 향상 시킬 수 있다.

동적원심모형실험 및 응답스펙트럼해석을 통한 포화지반에 관입된 잔교식 안벽의 내진성능 평가 (Evaluation of Seismic Performance of Pile-supported Wharves Installed in Saturated Sand through Response Spectrum Analysis and Dynamic Centrifuge Model Test)

  • 윤정원;한진태;이석형
    • 한국지반공학회논문집
    • /
    • 제37권12호
    • /
    • pp.73-87
    • /
    • 2021
  • 잔교식 구조물은 선박을 안전하게 접안하여 화물을 송수신할 수 있는 구조물로서, 포화된 경사지반에 주로 설치된다. 이러한 잔교식 구조물의 내진설계 시 기준서에서는 예비 설계 방법으로 응답스펙트럼해석법을 활용하도록 제시하고 있으나, 현재 포화지반에 관입된 잔교식 구조물의 모델링 방법에 대한 지침은 부족한 실정이다. 그러므로 본 연구에서는 포화지반에 관입된 잔교식 구조물의 내진성능을 평가하기 위해 동적원심모형실험 및 응답스펙트럼해석을 수행하였다. 동적원심모형실험을 위해 잔교식 안벽 말뚝 중 일부 구간(3×3 군말뚝)을 선정하였으며, 지반 포화 여부에 따라 2가지 모델(건조, 포화)로 분류하였다. 이후 실험 모델에 지반 스프링 방법을 적용하여 응답스펙트럼해석을 수행하였다. 실험 및 해석을 비교한 결과, 건조지반 모델 및 액상화가 발생하지 않는 포화지반 모델의 경우 모멘트 차이가 최대 51% 이내로 발생하였으며, 깊이 별 모멘트를 적절히 모사하는 것으로 나타났다. 그러므로 본 모델의 경우 Terzaghi(1955)가 제시한 수평지반반력상수를 활용하여 모델링을 수행하는 것이 적절한 것으로 판단된다.

나노임프린트 장비용 대면적 열판 열설계를 위한 수치 연구 (A NUMERICAL STUDY ON THERMAL DESIGN OF A LARGE-AREA HOT PLATE FOR THERMAL NANOIMPRINT LITHOGRAPHY)

  • 박규진;이재종;곽호상
    • 한국전산유체공학회지
    • /
    • 제21권2호
    • /
    • pp.90-98
    • /
    • 2016
  • A numerical study is conducted on thermal performance of a large-area hot plate specially designed as a heating and cooling tool for thermal nanoimprint lithography process. The hot plate has a dimension of $240mm{\times}240mm{\times}20mm$, in which a series of cartridge heaters and cooling holes are installed. The material is stainless steel selected for enduring the high molding pressure. A numerical model based on the ANSYS Fluent is employed to predict the thermal behavior of the hot plate both in heating and cooling phases. The PID thermal control of the device is modeled by adding user defined functions. The results of numerical computation demonstrate that the use of cartridge heaters provides sufficient heat-up performance and the active liquid cooling in the cooling holes provides the required cool-down performance. However, a crucial technical issue is raised that the proposed design poses a large temperature non-uniformity in the steady heating phase and in the transient cooling phase. As a remedy, a new hot plate in which heat pipes are installed in the cooling holes is considered. The numerical results show that the installation of heat pipes could enhance the temperature uniformity both in the heating and cooling phases.

셀룰로오스와 PET 복합체로 만들어진 가습소자의 가습성능 (Performance of Humidifying Element Made of Cellulose and PET Composite)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.1658-1663
    • /
    • 2015
  • 실내의 습도제어를 위하여 공조기 내에는 가습소자가 설치된다. 지금까지 대부분의 가습소자는 유리섬유로 만들어진 외제품이 널리 사용되어 왔다. 본 연구에서는 이 외제품을 대체할 셀룰로오스와 PET 복합체로 만들어진 가습소자를 개발하고 유리섬유로 만들어진 Glasdek 소자의 성능과 비교하였다. 시험은 소자를 항온항습실 내에 설치된 흡입식 풍동입구에 설치하고 물질전달량과 압력손실을 측정하였다. 실험결과를 $j_m$과 f인자로 나타내었을 때, 개발품의 $j_m$값이 33%~39%크고, f인자는 개발품이 0%~51% 작게 나타났다. Glasdek에 비하여 개발품의 $j_m$값이 큰 이유는 흡수도가 월등히(50% 가량) 크기 때문이고 f인자가 작은 이유는 소자 표면이 확연히 매끄럽기 때문이다. 한편, 동일 소비동력 대비 물질전달을 나타내는 $j_m/f^{1/3}$ 의 경우, 개발품이 약 36~63% 크게 나타났다.

저에너지주택의 지열히트펌프시스템 냉·난방 성능분석 (Heating and Cooling Performance Analysis of Ground Source Heat Pump System in Low Energy House)

  • 백남춘;김성범;신우철
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.387-393
    • /
    • 2016
  • A ground source heat pump system maintains a constant efficiency due to its stable heat source and radiant heat temperature which provide a more effective thermal performance than that of the air source heat pump system. As an eco-friendly renewable energy source, it can reduce electric power and carbon dioxide. In this study, we analyzed one year of data from a web based remote monitoring system to estimate the thermal performance of GSHP with the capacity of 3RT, which is installed in a low energy house located in Daejeon, Korea. This GSHP system is a hybrid system connected to a solar hot water system. Cold and hot water stored in a buffer tank is supplied to six ceiling cassette type fan coil units and a floor panel heating system installed in each room. The results are as follows. First, the GSHP system was operated for ten minutes intermittently in summer in order to decrease the heat load caused by super-insulation. Second, the energy consumption in winter where the system was operated throughout the entire day was 7.5 times higher than that in summer. Moreover, the annual COP of the heating and cooling system was 4.1 in summer and 4.2 in winter, showing little difference. Third, the outlet temperature of the ground heat exchanger in winter decreased from $13^{\circ}C$ in November to $9^{\circ}C$ in February, while that in summer increased from $14^{\circ}C$ to $17^{\circ}C$ showing that the temperature change in winter is greater than that in summer.