• Title/Summary/Keyword: Installations Condition

Search Result 39, Processing Time 0.022 seconds

The Analysis of Field Condition for Power Receiving System and Patch and Panel Boards at Construction Sites (건설현장의 수전설비 및 배.분전반의 현장실태 분석)

  • Gil, Hyoung-Jun;Han, Woon-Ki;Kim, Hyang-Kon;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.335-340
    • /
    • 2004
  • To analyze risk factors of temporary power installations, the investigation was carried out for power receiving system and pack and panel boards at construction sites. The subject was variable such as an airport, an apartment, a municipal playground. There are many risk factors caused by inadequate working environments and the deterioration of temporary power installations using equipment with minimum safety devices at construction sites. There, it is intended to present problems and preventive measures against electrical shock accidents, through analyzing risk factors of real field condition and investigating temporary power installations all over the country.

  • PDF

The Investigation and Analysis of Field Condition on the Electrical Shock Hazard of Electrical Facilities Used for Temporary Power Supply at Construction Site (임시전력 건설현장에 사용되는 전기설비의 감전위험에 관한 현장실태 조사 및 분석)

  • Gil, Hyoung-Jun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.197-204
    • /
    • 2004
  • The temporary power installations are to be used for temporarily supplying power during work at construction sites and have a minimum of protective devices to differ from permanent installations. There are many risk factors caused by loose working environments, deterioration of installations at construction sites. To analyze risk factors of temporary power installations, the investigation and the questionnaire were carried out side by side for power receiving system patch and panel boards, and were performed by researcher, the related expert, engineer of Korea Electrical Safety Corporation all over the country. The objects were variable such as an airport, an apartment, a municipal playground As a result, there are many problems such as a bad lock, poor protection of charging department. Solvable methods are improvement of the related regulation safety education, safety check and so on. In the future, the analytical data can be applied to prevent the electrical shock at construction site, and can be used to stabilize electrical installations.

Development of Smart Power Outlet and Controller Installations (지능화된 부하 감시 및 제어 설비의 개발)

  • Park, Chan-Won;Park, Hee-Suk;Ban, Yun-Ho
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.3 no.2
    • /
    • pp.33-41
    • /
    • 2004
  • This paper describes a development of smart power outlet and controller installation which is equipped for discrete power load environment such as office and home appliance. This system will sense a real-time power consumption and analyze the status, then, will keep optimal power use condition. The proposed method is applied to the real design, and that experimental results showed good performances on the wall-outlet, also, is expected to be used in the smart home automation installations.

  • PDF

A Study on the Analysis of Field Condition for Ground Fault Protection Installation among Electrical Installations in the Entertainment Area (공연장의 전기설비중 지락보호설비에 대한 현장실태분석 연구)

  • Bae, S.M.;Kim, H.S.;Gil, H.J.;Lee, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1721-1723
    • /
    • 2002
  • This paper deals with the analysis of field condition for earth leakage current alarming system in the stage lighting, stage sound stage machinery installation. These analyses of field condition were carried out in accordance with investigating an installation of earth leakage current alarming system with respect to a main line of power source, dimmer, sound equipment, machinery mobile unit equipment and so on. As a result of analyses. The earth leakage current alarming system has been installed only a part of the main line of power source and the probability of places which were installed was less than 50(%). Therefore, it is desirable that the earth leakage current alarming system is installed at places which are suitable, for example, dimmer, each kind machinery etc. in order to prevent electrical hazard.

  • PDF

Measures to Prevent Recurrence through the Analysis of an Explosion Case at Ammonia Refrigeration Facilities (암모니아 냉동시설의 폭발사례 분석을 통한 재발방지대책)

  • Ryu, Young-Jo;Lee, Min-Kyung;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.38-45
    • /
    • 2016
  • In this study, we found that the release and dispersion of ammonia can create hazardous atmospheres using FLACS software. In General, ventilation or gas detector installations are recommended as preventive measures to control explosion incidents. However, the ventilation installations cannot be applicable to the refrigeration facility that uses ammonia as refrigerating medium, because the freezing room should be sealed. From the accident investigation of the explosion case, we suggested that all electronic devices were needed to be switched by explosion proof devices, and communication facility was also needed to be installed to announce to all employees within a building in case alert condition like ammonia releases occurred.

Analysis on the Effects by Weather Conditions of Infrared Thermography (기상조건이 적외선 열화상에 미치는 영향 분석)

  • Lim, Young-Bae;Choi, Myeong-Il;Kim, Gi-Hyun;Park, Chee-Hyun;Bae, Seok-Myung;Cho, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.3
    • /
    • pp.142-147
    • /
    • 2007
  • Infrared thermography is one of the most valuable and cost-effective diagnostic techniques for predictive maintenance on electrical systems. For the electric installations, the thermographies can identify major problems, which if left unattended could lead to breakdowns. The result thermal images depend upon operator skills, inspection technique, and load and weather conditions. When the thermographer is applied to remote monitoring, the conditions of the systems are not perfectly analyzed because operators are hard to know the weather's effects of the installed place. Therefore, this paper defines the effects by weather conditions which will influence the final results. The purpose of this paper is to define the weather effects that a thermographer needs to consider for successful condition analysis.

Development of Vehicle Environment for Field Operational Test Data Base of Driver-vehicle's Behaviour (운전자 거동에 대한 필드 데이터베이스 구축을 위한 차량 환경 개발)

  • Kim, Jinyong;Jeong, Changhyun;Jeong, Minji;Jung, Dohyun;Woo, Jinmyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Recently, the automotive technology has developed with electronics and information technology as convergence technology while vehicles had been regarded as machines. Moreover, vehicles are becoming more intelligent and safer devices, assembly of advanced technologies by customers' demand. Even though all of installations of vehicle have attracted as diverting devices, it cause drivers' mistakes like delay of response on traffic condition. Here, we proposed the Field Operational Test (FOT) environment which could be used as driving and road conditions collector(Vehicle motion, Traffic condition, Driver input, Driver state, etc.) for researches about Driver Friendly Intelligent System(SCC, LDWS, etc.), Human Vehicle Interface(Driving Workload, etc.) and Economic Drive Model. Furthermore driving patten and fuel consumption patten of drivers were analyzed by measured data and direction of future research was suggested.

Effect of Boundary Condition on Buckling Characteristics of Pipe Supports (파이프 서포트의 좌굴특성에 대한 지지조건의 영향)

  • Lee, Jin Seop;Lee, Yeon Su;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.2
    • /
    • pp.41-47
    • /
    • 2015
  • Recently, a lot more disasters in the temporary structures happen because the stabilities of the temporary structures are disregarded by the reduction of the unit cost, using defective materials, the existing materials and so on. Pipe supports, which are one of the temporary structures, are basically used for the most constructing works such as buildings, bridges, plants and so on. In the most sites, adequate support installations of the pipe supports have not been performed although the presence of the guideline legally and institutionally. In this study, therefore, the collapse accidents of the pipe supports were investigated on the basis of theoretical analysis as well as the buckling tests by simulating the site support condition. Both the theocratical analysis and test results show that the buckling load in the fixed ends is at least 4 times larger than one in the pinned ends. This results will be utilized for safety assurance as well as accident prevention the in the field application.

An improved regularized particle filter for remaining useful life prediction in nuclear plant electric gate valves

  • Xu, Ren-yi;Wang, Hang;Peng, Min-jun;Liu, Yong-kuo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2107-2119
    • /
    • 2022
  • Accurate remaining useful life (RUL) prediction for critical components of nuclear power equipment is an important way to realize aging management of nuclear power equipment. The electric gate valve is one of the most safety-critical and widely distributed mechanical equipment in nuclear power installations. However, the electric gate valve's extended service in nuclear installations causes aging and degradation induced by crack propagation and leakages. Hence, it is necessary to develop a robust RUL prediction method to evaluate its operating state. Although the particle filter(PF) algorithm and its variants can deal with this nonlinear problem effectively, they suffer from severe particle degeneracy and depletion, which leads to its sub-optimal performance. In this study, we combined the whale algorithm with regularized particle filtering(RPF) to rationalize the particle distribution before resampling, so as to solve the problem of particle degradation, and for valve RUL prediction. The valve's crack propagation is studied using the RPF approach, which takes the Paris Law as a condition function. The crack growth is observed and updated using the root-mean-square (RMS) signal collected from the acoustic emission sensor. At the same time, the proposed method is compared with other optimization algorithms, such as particle swarm optimization algorithm, and verified by the realistic valve aging experimental data. The conclusion shows that the proposed method can effectively predict and analyze the typical valve degradation patterns.

Development of Program for Qualitative Risk Based Inspection (RBI) using API-581 (API-581에 의한 정성적 위험기반검사(RBI) 프로그램 개발)

  • 이헌창;유준;김환주;김태옥
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.1
    • /
    • pp.49-60
    • /
    • 2004
  • Industrial facilities are becoming more complex and various with rapidly developing technologies. A number of installations and equipments are increased to improve productivity, and they are operated under the condition of high temperature and pressure. They are continuously repaired, replaced or abolished because of the deterioration with time, but their repair and replacement are not easy for economical and environmental concerns. If possible, the deteriorating equipments should be inspected and repaired effectively considering the state of maintenance and preservation, economic efficiency, and safety. That's where RBI(Risk Based Inspection) fits in. Even if RBI technology has been known among specialists, there were no tools readily available and it was hard to practice and apply RBI in industrial inspection and safety management. In the development of the qualitative RBI, the overall algorithm adopted API-581 BRD. The qualitative RBI program was developed to search the appling process.