A Branch-and-price Approach to the ATM Switching Node Location Problem

  • Kim, Deokseong;Park, Sunsoo;Lee, Kyungsik;Park, Kyungchul
    • Industrial Engineering and Management Systems
    • /
    • v.3 no.2
    • /
    • pp.92-99
    • /
    • 2004
  • We consider the ATM switching node location problem (ANLP). In this problem, there are two kinds of facilities, hub facilities and remote facilities, with different capacities and installation costs. We are given a set of customers with each demand requirements, a set of candidate installation sites of facilities, and connection costs between facilities. We need to determine the locations to place facilities, the number of facilities for each selected location, the set of customers who are connected to each installed hub via installed remote facilities with minimum cost, while satisfying demand requirements of each customer. We formulate this problem as a general integer programming problem and solve it to optimality. In this paper, we present a preprocessing procedure to tighten the formulation and develop a branch-and-price algorithm. In the algorithm, we consider the integer knapsack problem as the column generation problem. Computational experiments show that the algorithm gives optimal solutions in a reasonable time.

Effect of droplet protection screen height on the prevention ability of infectious droplet airborne transmission in closed space (밀폐공간에서 비말 가림막 높이에 따른 감염성 비말 공기전파 차단능력 평가)

  • Heo, Jieun;Cho, Hee-joo;Park, Hyun-Seol;Shin, Dongho;Shim, Joonmok;Joe, Yun-Haeng
    • Particle and aerosol research
    • /
    • v.17 no.2
    • /
    • pp.37-42
    • /
    • 2021
  • Although the installation of droplet protection screen (DPS) is known to prevent droplet transmission, there is still a lack of knowledge in effectiveness of DPS installation to block the airborne transmission. In this study, the prevention ability of DPS against airborne transmission was evaluated according to the DPS height. When the DPS was not installed, the maximum concentration of PM1.0 at the location opposite to infected person was 35% of that at the infected person location. When the DPS was installed, the DPS effectively prevented the airborne transmission, consequently approximately 7% of generated particles were measured at the opposite location from particle generation position (infected person location). The prevention ability of DPS increased with DPS height, the maximum prevention efficiency of 95.1% was obtained when the DPS height was 900mm. Moreover, the speed of airborne transmission was delayed by installation of DPS, and the delay time increased with DPS height.

Management after installation of artificial fish reefs -Present Condition and Development Scheme- (인공어초 사후관리 현황과 발전방향)

  • Ahn Seung-Hwan;Kim Dong-Sun;Park Gyeong-Won;Lee Sung-il
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2005.11a
    • /
    • pp.139-141
    • /
    • 2005
  • It is important to manage artificial fish reefs with installation for restoration. we made survey for installation's condition(location, amount etc), fish community and amount of fishing net around installation area(6,142ha) in Yeosu of artificial fish reefs with side scan sonar and diving. Also we suggests better method of management after installation of artificial fish reefs.

  • PDF

Comparison of Acoustic Performance Depending on the Location of Sound Absorptive and Diffuser in Small Auditoriums Using 1/10 Scale Models (1/10 축소모형을 이용한 소공연장의 흡음재와 확산체의 적용위치에 따른 음향성능 비교)

  • Kim, Tae-Hee;Park, Chan-Jae;Park, Ji-Hoon;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.146-156
    • /
    • 2015
  • This study investigated how the location of sound absorptive materials and sound diffusers affects the acoustic performance of small auditoriums. It was conducted for a standard model established with the averaged dimension of 36 auditoriums which had opened since 2000 in Daehak-ro, Seoul. In this study, the installation area of finishing materials was calculated upon a back wall which had the smallest installation effective area of finishing materials. To analyze the changes of acoustic performance according to installation location of finishing materials, experiments were carried out using the 1/10 down scale models for 8 cases which were made by classifying the installation location of ceiling and side wall into the front, middle and rear part.The used acoustic parameters were reverberation time (RT), early decay time (EDT), clarity (C80), definition (D50) and speech transmission index (STI). In result, the index related to the amount of reverberant sound (RT, EDT) showed the great changes when evaluating it through just noticeable difference (JND), but the one related to clarity (C80, D50, STI) hardly indicated the changes. In case to obtain short reverberation time, it was most effective to control reverberation time through the side walls when installing sound absorptive and diffusive materials, and side wall front was the location which could get the shortest reverberation time.

Solar Power Plant Location Analysis Using GIS and Analytic Hierarchy Process (GIS와 계층분석법을 이용한 태양광 발전소 입지 분석)

  • LEE, Ki-Rim;LEE, Won-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.4
    • /
    • pp.1-13
    • /
    • 2015
  • The interest in renewable energy which can reduce greenhouse gas emissions has risen in the world including Korea. In Korea, solar energy generation accounts for a major percentage of electricity production using renewable energy and the solar power plants have been increasingly installed in Korea. The problem is, however, that researches on the location selection of solar power plants are unreasonably insufficient although the photovoltaic technology of the domestic solar power plants has been evolving. Thus, advanced solar energy technology could not be fully used. What is more, the indiscriminate installation of the solar power plants seriously damages the nature environment. In this study, conditions of the power plants location are analyzed in consideration of the social, cultural, environmental, economic factors and the optimum location is selected by visualizing and weighing various factors through the analytic hierarchy process. This study shows that the problem caused by the indiscriminate installation of a solar power plant could be prevented by determining the location after considering the influence of several factors. This paper would be helpful not only for the selection of location for solar plant installation in progress, but also for taking follow-up measures on the existing solar power plants placed wrongly.

A Study on the Improvement Method for Efficient Service of E-GEN AED using Time and Spatial Data (시·공간 데이터를 활용한 E-GEN AED의 효율적 서비스를 위한 개선방안)

  • Beak, Seong Ryul;Kim, Jun Hyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.4
    • /
    • pp.253-265
    • /
    • 2019
  • In this study were analyzed the errors on the registration of details information, location of E-GEN (Emergency medical-GEN) AED (Automated External Defibrillator) installation site and the adequacy of spatial arrangement, which suggests an improvement methods of constructing an app or web based on time and space data for efficient operation of considering accessibility and usability. As a result of this study, first, it was not equal to each other for locations of each installation point of AED, that confirmed some area were dense or requiring additional installation. Second, it confirmed the inaccuracies in inputting and registering information about the installed location, such as the actual installation location information and the attribute information of the AED. Third, the main access node and the main address node were connected to a straight line that was found not be connected to the back door, the straight line, the stairs. Also, the opening times of AED installation sites varied according to the week and the season, the entrance was managed by the apartment management office in a separate place, it needs to be established on this information. In conclusion, it proposed a method to improve spatial equity and accessibility, a method to provide accurate distance and time according to actual movement routes in case of emergency, and a possibility of using each facility considering day and time.

Wind Resource Assessment of the Antarctic King Sejong Station by Computational Flow Analysis (남극 세종기지의 전산유동해석에 의한 풍력자원평가)

  • Kim, Seok-Woo;Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.29-35
    • /
    • 2007
  • In accordance with Madrid and Kyoto Protocols, a 10kw wind turbine installed about 625m away from the King Sejong Station in the Antarctica has been in operation successfully. The current location of the wind turbine has different geographic surroundings from the previous candidate site considered in 2005 and that makes re-evaluation of wind resource at the current site including geographic effects necessary. Especially, strong wind flow derived by steep and complex terrain is dominant in the Antarctica so that computational flow analysis is required. The wind rose measured at the previous and current installation location are identical with strong meteorological correlation but prevailing directions of wind power density are different because of local wind acceleration due to complex terrain. Numerical analysis explains which effects brings this discordance between the two sites, and a design guideline required for additional wind turbine installation has been secured.

A Survey and Analysis on the Location of Offshore Wind Power Generator Facilities (해상풍력발전 입지 선정에 관한 조사 및 분석)

  • Kim, Joo-Suk;Jeon, Tae-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.435-438
    • /
    • 2009
  • With the development of human civilization, humanity has grown to use enormous of energy. As the use of energy increases, although human life has become prosperous and materially plentiful, the consequent problems are becoming more serious day by day. The main cause of the emission of greenhouse gases is the enormous amount of carbon dioxide generated by the burning of fossil fuels. Many land-based wind power generator facilities complexes, which is one of the new renewable energy sources, have currently been completed and put in operation or are planned to bo constructed in Korea. However, in consideration of the economy and the effect on the environment, the progressive trend is to plan and install such complexes at sea rather than on land. In this paper, we shall investigate and analyze the location selection for offshore wind power generator facilities.

  • PDF

System Loss Improvement through Proper Location of Active and Reactive Power Apparatus (유무효전력설비의 적소투입을 통한 전력손실개선)

  • 이상중
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.77-80
    • /
    • 2000
  • This paper presents a method for improving the power loss through optimal location of active or reactive power apparatus. The paper introduces the los sensitivities which imply the variation of the power loss with respect to the incremental bus power P, Q and uses them as the investment information for the active and reactive power apparatus. Power apparatus are invested, by the priority of loss sensitivities indices given for each bus.

  • PDF

The Development and Performance Evaluation of Adaptive Monitoring sensor for the Marine IT System (해양 IT시스템용 적응형 모니터링 센서의 개발 및 성능 평가)

  • Cho, Jeong-Hwan;Roh, Hee-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.90-95
    • /
    • 2015
  • This paper proposes the new adaptive gain control monitoring sensor for the marine IT system. The marine IT system sensors make it possible to conduct search missions, record climate changes, provide pollution control, study marine life, conduct survey missions, tactical surveillance, and predict natural disturbances in the ocean. In this paper, the adaptive gain control circuit which changes its parameters according to the ambient noise situation for obtaining the precise location information of marine IT system sensor is developed and analyzed. The performance characteristics for ensuring the precise location information of marine system sensor is presented and analyzed. The theoretical and experimental studies have been carried out. The presented results from the above investigation show considerably excellent performance for the monitoring of the marine system.