• Title/Summary/Keyword: Installation equipment

검색결과 920건 처리시간 0.023초

조명기기의 임펄스내전압 성능의 분석 (Analysis of Impulse Withstand Voltage Performance of Lighting Equipment)

  • 이복희;방평호
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.91-96
    • /
    • 2014
  • Modern electronic circuits are becoming more vulnerable to damage by surges, and it is required to improve the impulse withstand voltage performance of electrical and electronic equipment. This paper presents the impulse withstand voltage performance of lighting equipment connected to power lines, and the impulse withstand voltage tests for fluorescent lamp, LED lamp and halogen lamp were carried out according to the reference standards under normal service conditions. To conduct performance tests against lightning surge, a combination wave ($1.2/50{\mu}s$ voltage - $8/20{\mu}s$ current) was employed. The test surge was applied between lines or between line and ground of the specimen to be measured. The test surge was applied synchronized at the peak value of the positive and negative AC voltage waves. As a consequence, some specimens satisfied the impulse withstand voltage test criteria, but lighting equipment such as 36W fluorescent lamps, 5W and 5.5W LED lamps and 50W halogen lamp were damaged at the test voltage levels between power lines. It is needed to improve the qualities of lighting equipment to satisfy EMC immunity requirements of equipment for general lighting purposes.

마샬시험 장치 및 설치조건이 다짐에너지와 안정도에 미치는 영향 (Effect of the Compaction Energy and the Marshall Stability due to the Marshall Equipments and Installation Conditions)

  • 박태순;김용주
    • 한국도로학회논문집
    • /
    • 제2권4호
    • /
    • pp.123-131
    • /
    • 2000
  • 아스팔트 포장의 배합설계 방법에서 사용하고 있는 마샬시험 장치는 다짐장치와 안정도 헤드의 주요한 두 부분으로 이루어져 있다. 다짐장치는 시료의 공극과 다짐도에 영향을 미치며 안정도헤드는 마샬안정도와 흐름치에 영향을 주기 때문에 다짐장치의 규격과 타격에너지, 안정도헤드의 형상은 어떠한 경우라도 일치하여야 배합설계시 최적아스팔트 함량을 정확하게 분석 할 수 있다. 그러나, 본 연구의 결과에 의하면 국내에서 사용되고 있는 마샬시험 장치는 서로 다른 규격과 형상을 가지고 있음은 물론, 각 기관마다 다짐장치를 설치하는 조건과 각 제조회사 장치의 받침목이 서로 상이하여 시험 결과의 오차는 물론 아스팔트 포장의 공용성에도 크게 영향을 미치기 때문에 마샬시험 장치의 범 국가적인 재정비가 필요한 것으로 나타났다.

  • PDF

건축물에 시설되는 수변전설비의 지진 대책에 대한 조사 분석 (Analysis of earthquake countermeasure for electrical facility at building)

  • 김기현;이상익;전현재;배석명
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.359-362
    • /
    • 2008
  • Middle domestic the occurrence size which stews recently from the Korean Peninsula circumference country is augmenting on a large scale about earthquake about safe countermeasure part from the existing Natural Countermeasure Law 2008. Refers with the Earthquake Disaster Countermeasure Law to be new standard contents establishment by law and strengthened in March. Consequently the research is propelled about electric equipment earthquake-proof plan and countermeasure. The present paper investigated an equipment by domestic facility present condition about the change disappointment electric equipment which can supply all the member in the building an investigation analysis about problem point and improvement fact. Also about overseas electric equipment investigated about earthquake-proof plan relation system and facility present condition. Investigated the electric equipment earthquake-proof plan pertinent data which is advanced from like this existing nation and the equipment and application direction must apply to domestic presented. With character presents following the guide about electric equipment earthquake-proof plan becomes feed with the fact that will be able to use.

  • PDF

제어설비 계통에서의 노이즈장해 사례 및 대책별 효과 분석 (The Effect Analysis in case of the Countermeasure and Trouble-Examples for the Noise of Control Equipment System)

  • 김홍주;유상봉;이호성
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.75-81
    • /
    • 2005
  • 최근 제어설비 계통은 전력변환장치와 센서등의 사용이 증가함에 따라 많은 노이즈가 발생되어 설비의 오동작이나 제어 회로의 메모리 손실과 같은 문제들이 야기되고 있다. 따라서, 본 논문에서는 다양한 제어설비 계통에서 발생되고 있는 노이즈의 특성을 계측하고 분석하였다. 또한 NCT, 등전위 접지, PNR, 노이즈필터 등을 사용한 노이즈저감 대책을 적용한 결과로 이들 대책들이 노이즈 문제 해결에 매우 효과적임을 확인하였다.

변압기 절연열화진단 시스템개발에 관한 고찰 (Study on Development of Insulation Degradation Diagnosis System for Electrical Transformer)

  • 김이곤;유권종;김서영;조용섭;박봉서;최시영;심상욱
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.139-144
    • /
    • 2001
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defect. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear, it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a magnetic wave and acoustic signal to diagnoses an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System) and acquires 2D patterns from analyzing it. For filtering the noise contained in sensor signals we used ICA algorithms. Using this data, design of the neuro-fuzzy model that diagnoses an electrical equipment is investigated. Validity of the new method is asserted by numerical simulation.

  • PDF

제어설비 계통의 노이즈장해 사례 및 대척에 관한 연구 (A Study on the Countermeasure and Trouble-Examples by Noise in Control Equipment System)

  • 유상봉;김홍주;이호성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.325-330
    • /
    • 2005
  • 최근 제어설비 계통은 전력변환장치와 센서의 사용이 증가하여 많은 노이즈가 발생되고 있다. 이 노이즈로 인해 설비의 오동작과 제어 회로의 메모리 손실이 발생된다. 따라서, 본 논문에서는 제어설비 계통의 노이즈 발생량을 계측 분석하였고, 이에 따라 NCT, 등전위 접지, PNR, 노이즈필터와 같이 노이즈 감소를 위한 효과적인 보호설비를 적용하였고 계측 결과를 제시하였다.

  • PDF

전원 및 신호시스템에서의 뇌서지 전파양상 (Propagation Tendency of Lightning Surge in the Power and Communication System)

  • 이태형;조성철;엄주홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.245-249
    • /
    • 2007
  • The tendency of lightning surge to propagate displays the difference for applicable power and equipment. However, looking into the subject equipment with the lightning surge, the lightning surge can be divided in between the two lines of power, between the power line and the ground, the power line and the PE conductor, between the neutral line and the ground and the like. In addition, in the event of the communication equipment, there exists the case of lightning surge entered from the power line in addition to the entry between the communication lines, the communication line and the ground. In this study, the tendency of propagation of lightning surge penetrated on to the subject equipment is analyzed through the empirical experiment in accordance with the ground method by using the independent ground, common ground, bypass arrester and others among the techniques for safety improvement in power lines.

  • PDF

Portable Calibration System for Displacement Measuring Sensors

  • Eom, Tae-Bong;Lee, Jae-Yun;Kim, Jae-Wan;Joon, Lyou
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권2호
    • /
    • pp.56-59
    • /
    • 2006
  • A vibrational model of powder transfer equipment based on the lumped parameter method was developed, in which the operating motion consists of surging, bouncing, and pitching. After decoupling the equation of motion, the vibrational excitation source of the pitching motion was removed. So the designers are able to plan the optimum design to adjust the motion trajectory of the powder transfer equipment. That is, a procedure to adjust the motion trajectory of powder transfer equipment by changing design specifications such as the installation position, the direction of the motor, the driving speed, the mass unbalance, the stiffness coefficient, and the installation position of the support spring, is presented in this paper. The powder transfer equipment manufactured according to the results of this study did not suffer fatigue destruction, since the maximum stress on the basket structure was sufficiently small.