• 제목/요약/키워드: Installation depth

Search Result 359, Processing Time 0.029 seconds

A study on the fire smoke diffusion delay strategy in a great depth underground double deck tunnel junction (대심도 복층터널 교차로 화재연기 확산지연 방안 연구)

  • Shin, Tae-Gyun;Moon, Jung-Joo;Yang, Yong-Won;Lee, Yun-Taek;Han, Jae-Hee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.115-126
    • /
    • 2019
  • Recently, in order to solve the traffic congestion in urban areas and to improve the peripheral environment, research on the design and construction technology development of great depth underground double-deck tunnel is under way by using the underground space in the urban area. The network type double-deck tunnel is in the form of an intersection with a small cross section and a steep slope as per construction at the base of a flatland, so that the fire smoke spreads rapidly in case of fire, which is expected to cause damage of human life. Therefore, this study is analyzed the delay effect of fire smoke diffusion according to the installation and non - installation of delay system for fire smoke diffusion at the intersection. Fire fumes were delayed up to 270 seconds when the delay system for fire smoke diffusion was installed at the intersection and it is analyzed that the greater the operating area of the delay system for fire smoke diffusion, the more preventable the damage of human life of the intersection.

Application of magnetotelluric survey for development of deep geothermal water at Seokmo Island, Korea (석모도 지열수 개발을 위한 자기지전류탐사의 적용)

  • Lee, Tae-Jong;Song, Yoon-Ho;Park, Deok-Won
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.4 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • A magnetotelluric survey and geological survey have been performed to delineate deeply extended fracture systems at the geothermal field in Seokmo Island, Inchon, Korea. One borehole(BH-1) succeed to meet a large fracture system at the depth of 750 m where approximately $72^{\circ}C$ geothermal water is overflowing, while the other borehole(BH-2), which is about 200 m eastward from BH-1, failed to develop enough geothermal water even at the depth of 1,200m. Though there have been so many electric noise sources around the survey region, good quality of MT data above 1 Hz could be obtained with careful installation, remote reference processing. Inversion of MT data for two lines roughly perpendicular to the two major lineaments respectively show that the two lineaments are related to the fracture systems that are extended at least down to 1.5 km depth and inclined eastwards. From the interpretation, additional drilling for BH-2 is recommended and finally meet the fracture systems at the depth of 1,280 m and resulted in overflow of large amount of geothermal water of temperature $69.4^{\circ}C$ from BH-2.

  • PDF

Heating and Cooling Effect of Portected Horticulture by Geothermal Heat Pump System with Horizontal Heat Exchanger (수평형 지열히트펌프 시스템의 시설원예 냉난방 실증 효과)

  • Ryou, Young-Sun;Kang, Youn-Ku;Kim, Young-Jung;Kang, Keun-Chun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.630-633
    • /
    • 2008
  • Geothermal heat pump systems use the earth as a heat source in heating mode and a heat sink in cooling mode. These systems can be used for heating or cooling systems in farm facilities such as greenhouses for protected horticulture, cattle sheds, mushroom house and etc. A horizontal type means that a geothermal heat exchanger is laid in the trench buried in 1.2 to 1.8 m depth. Because a horizontal type has advantages of low installation, operation and maintenance costs compared to a vertical type, it is easy to be adopted to agriculture. In this study, to heat and cool farm facilities and obtain basic data for practical application of horizontal geothermal heat pump system in agriculture, a horizontal geothermal heat pump system of 10 RT was installed in greenhouse. Heating and cooling performance of this system was estimated. The horizontal geothermal heat pump used in this study had heating COP of 4.57 at soil temperature of $14^{\circ}C$ with depth of 1.75m and heating COP of 3.75 at soil temperature of $7^{\circ}C$ with the same depth. The cooling COP was 2.7 at ground temperature at 1.75m depth of $25.5^{\circ}C$ and 2.0 at the temperature of $33.5^{\circ}C$.

  • PDF

Analysis of Influence Parameters to Evaluate the Effective Depth of Improvement of Dynamic Compaction Method (동다짐 공법의 유효다짐깊이 결정에 영향을 주는 인자 분석)

  • Kim, Hong-Taek;Lee, Hyuk-Jin;Park, Inn-Joon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.659-666
    • /
    • 2004
  • Dynamic compaction has evolved as an acceptable method of site improvement by treating poor soils in situ. The method is often an economical alternative for utilizing shallow foundations and preparing subgrades for construction when compared with conventional solutions. In general, the installation purpose of dynamic compaction are to increase bearing capacity and decrease differential settlement within a specified depth of improvement. This method involves the s systematically dropping large weights onto the ground surface to compact the underlying ground. The weights used on dynamic compaction projects have been typically constructed of steel plates, sand or concrete filled steel shells, and reinforced concrete. Typically, weights range from 5-20 ton and base configurations are, circular or octagonal. In this study, the effective depth of improvement is evaluated based on the numerical analysis code, the dynamic analysis of FLAC-3D program, in order to analyze the influence parameters ; ground conditions, maximum applied load and the area of compaction plate.

  • PDF

Elements and Actual Condition of Apartment Unit Remodeling - By In-depth Interviews on Residents and Specialists of Interior Design Companies - (아파트 단위주거의 리모델링 요소와 현황 - 인테리어디자인업체 실무자와 거주자 심층면접을 통하여 -)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Jeong, Youn-Hong
    • Journal of the Korean housing association
    • /
    • v.18 no.6
    • /
    • pp.57-67
    • /
    • 2007
  • The purpose of this study was to grasp major elements and actual condition of apartment unit remodeling by in-depth interviews on residents and specialists. The interviews had been conducted to interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment unit. In-depth interview is a kind of qualitative method in which attention to reply of responses with open-access between interviewer and respondents. According to the results, remodeling elements were generally changing of lighting fixtures and finishing materials in the all spaces, integration of balcony into children's room, installation of furniture in kitchen and entrance, changing storage furnitures and equipments in bathroom. Artificial lighting method were selected generally whole lighting. Finishing materials were used ordinary (non environmentally-friendly) wallpaper and adhesion and tempered floor. There were unsatisfied factors after remodeling, these were dissatisfaction of design, construction defects, and stink of reflecting 'sick house'. Also they responded that they should be considering to use environmentally-friendly material at next remodeling.

Fabrication of high-frequency therapy device for deep part and temperature distribution characteristic according to electrode condition of RET (심부투열용 고주파 치료기의 제작과 RET 전극조건에 따른 온도 분포 특성)

  • Jung, Jae-Won;Kim, Beong-Ju;Kim, Ki-Seon
    • Journal of Advanced Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.267-271
    • /
    • 2018
  • A high-frequency therapy device with improved output by modifying a high-frequency stimulator was fabricated. The details of the design include generating part design, high-frequency transformer design, large output FET installation, DC voltage input part design and gate input driver design. Based on the real test using the pork meat, the temperature distributions according to the current electric transfer method, penetration depth, electrode diameter size were measured. In the CET method, the penetration depth was 0.5 cm and in the RET method, the penetration depth was 20 cm or more. In addition, it was confirmed that the temperature rise according to the penetration depth in the RET system was substantially constant, and the temperature rise was remarkable as the electrode diameter was small. As a result, it has been confirmed that the high frequency therapy device is highly affected by various conditions of the electrode.

Installation Methods of Micro-piles by the Length Ratio of Pile and the Depth of Rock Layer (파일길이비와 암반층의 위치에 따른 마이크로파일 설치방법)

  • Hwang, Tae-Hyun;Kwon, Oh-Yeob
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.4
    • /
    • pp.5-20
    • /
    • 2011
  • A numerical analysis has been conducted to propose the effective installation methods of Micro-pile in a sandy soil or a soil with rock layer. As a result, the bearing capacity of reinforced soil by rigid Micro-pile has influence on a connection state of the tip of pile and surface of rock layer. But that by flexible Micro-pile has more influence on a penetration length of pile than the connection state of the tip of pile and surface of rock layer.

Distance Measurement and Three-Dimensional Image Display using Incoherent Holography (인코히어런트 홀로그래피를 이용한 거리계측과 3차원 영상 디스플레이)

  • 김수길;황보승
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • We derived the resolution of the modified triangular interferometer and described the analysis about distance measurement using the one. Also, to demonstrate the feasibility of distance measurement using the modified triangular interferometer, the incoherent hologram of a two-point source with depth and its numerical reconstruction were presented. We demonstrated the possibility of the modified triangular interferometer as a three-dimensional display by recording and reconstructing the incoherent hologram of three-dimensional image.

Radial Density Distributions in the Positive Column of a Strongly Modulated Mercury-rare gas AC Discharge (변조된 수은-희유기체 교류방전의 양광주 내의 반경방향 입자분포)

  • 이진우;여인선
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.2
    • /
    • pp.31-35
    • /
    • 1993
  • The radial density distributions of the positive column of strongly modulated low -pressure gas discharges in mercury - rare gas mixtures at 10 tom pressure have been studied theoretically. The current was modulated inusoidally with a modulation depth of 50%. Calculations have shown that the radial profile of the excited atoms is ditferent form 0th Bessel function $J_0$(2.4r/R) and the invertion of the radial distribution of the excited atom can occur at some frequency. The hybrid method of FDM and 2nd order Runge-Kutta meth od is used for solving differenzial equations.

  • PDF

Transient impedance characteristics of counterpoise according to the soil structures (대지구조에 따른 매설지선의 과도접지임피던스 특성)

  • Lee, Bok-Hee;Li, Feng;Jung, Dong-Cheol;Kim, Ki-Bok;Cho, Sung-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.311-314
    • /
    • 2009
  • This paper presents the characteristics of grounding impedance of counterpoises buried at various soil structures. Grounding impedance measurements were made by the Fall-of-Potential method. The experiments were carried out in 50 m counterpoise of 25 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the impulse generator having the front time of $1{\sim}60{\mu}s$. As a result, the soil structures greatly influences on the grounding impedance characteristics of counterpoise. The transient grounding impedances strongly depend on the injection mint and the front time of impulse current.

  • PDF