• 제목/요약/키워드: Installation Test

검색결과 1,492건 처리시간 0.025초

전력설비에 대한 내오손특성 평가설비 구축 (Construction of the evaluating facilities against contamination characteristic for power installation)

  • 이정기;김민규;정주영;김익수;문인욱;강영식;성문주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1851-1853
    • /
    • 2004
  • The important consideration in laboratory designing and construction of the artificial pollution testing facilities including 300kV, 1800kVA AC test system, which enable to test and evaluate the UHV dielectric performance of power insulators up to transmission class, has been dealt in this paper. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted. With the special consideration concerning other matters in designing of these testing facilities have been described with the fixed ratings and references.

  • PDF

PL법 대응을 위한 전력케이블의 열 충격 및 절연파괴 특성 (The Properties of Breakdown and Test for Resistance to Cracking of Power Cable for PL Countermeasure)

  • 김영석;송길목;김선구
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.349-352
    • /
    • 2007
  • It is impossible to database(DB) the patterns of cable events and cause analysis of faulted cable because the product liability(PL) law have been enforced in Korea, since 2002. In additions, simulation and pattern of cable events are needed for DB system under accelerated deterioration. In this paper, we tested for resistance to nicking of cable below the 22.9kV class due to thermal stresses. This method of exam is following IEC 60811-3-1(Common test methods for insulating and sheathing materials of electric cables). First of all, set the cable in the thermal stress instrument, temperature changed from -20 degree to 120 degree. After thermal stress, we observed a surface crack of cable through microscope and carried out AC withstand voltage test.

  • PDF

154kV 전력용 변압기의 온도분포에 관한 연구 (The Study on the Temperature Distribution for 154kV Power Transformers)

  • 우정욱;구교선;곽주식;김경탁;권동진
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.56-61
    • /
    • 2011
  • The temperature of power transformers is very important factor for power system operation in substation because load capacity and limited lifetime of power transformers are determined by winding temperature. Also, The temperature of power transformers varies with the structure, capacity, operation condition and manufacturers. Thus, it is necessary for temperature distribution to be exactly investigated because of efficient load management and prediction of limited lifetime. Nevertheless, there was no case of analysis as well as measurement of the temperature of power transformers. In this paper, we manufactured the 154kV standard power transformer for the test. And we measured the temperature by the heat run test and analyzed the temperature distribution of transformer.

제품 검사 시스템 개발에 관한 연구 (A Study on development of repeat check system for product)

  • 최영규
    • 한국정보전자통신기술학회논문지
    • /
    • 제6권3호
    • /
    • pp.156-161
    • /
    • 2013
  • 가스 밸브 제어기는 사용자의 취급부주의에 의해 폭발, 화재 및 질식 등의 사고를 미연에 방지하고자 사용 시간을 설정하여 가스를 사용할 수 있는 시스템이다. 가스 밸브는 각 수용가에서 한 번 설치를 하면 특별한 사안이 없는 한 교체하지 않는 품목 중의 하나로서, 설치 이전에 충분한 시험이 필요한 장치이다. 본 연구에서는 가스 밸브 제어기를 사용 횟수를 설정하여 시험할 수 있는 시스템을 개발하였다.

외관불량 배전용 콘크리트전주 건전도 평가지표 개발 (A Development of Soundness Evaluation Index for Poor Appearance Distribution Concrete Poles)

  • 왕윤찬
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.35-44
    • /
    • 2014
  • This study was to secure the safety of poor appearance distribution concrete poles effectively and to reduce the replacement costs of them by developing a soundness evaluation index. The researcher of this study investigated poor appearance types of concrete pole, collected 53 of test samples, and tested pole strength. As a result of strength test, only 17 percent of poor appearance concrete poles were below 2.0 of safety factor spec. As results of multiple regression analysis, it is verified that surface air void, horizontal crack, net-shaped crack, elapsed year, vertical crack, and deterioration in concrete compressive strength have statistically negative effects on safety factor of concrete poles in a significant level. The researcher set up a soundness evaluation index by using multiple regression equation, and suggested that poor appearance concrete poles should be replaced or reinforced only in case of soundness evaluation score of 150 or above.

분산전원이 연결된 22.9[kV] 배전계통의 양방향 보호기기 실증시험 연구 (The Study on the Actual Examination of the Bidirectional Protection Device in the 22.9[kV] Distribution Power System Interconnected with the DG)

  • 이흥재;최명호
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.102-108
    • /
    • 2011
  • The existing power flow has a single direction to the line end but the bidirectional power flow will possibly occur depending on the output capacity in the 22.9[kV] distribution power system connected with the dispersed generation(DG). So these characteristics would influence the power system management. The DG have many advantages such as assistance source, Load share etc. So the utility must apply the bidirectional protection system so as to maximize an advantage of DG. This paper describes the field test case of bidirectional protective device in order to investigate the device performance when applied to bidirectional power system. We have tested in the power system test site of KEPCO and these tests provide the basis for performance verification test of bidirectional protective device in the power system.

마이크로그리드용 10[kW] PCS 개발 및 성능시험 (The Development & Performance Test of 10[kW] Power Conditioning System for Microgrid)

  • 이학주;채우규;박중성;김주용;김찬영
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.55-62
    • /
    • 2011
  • PCS(Power Conditioning System) is the necessary component in Microgrid, composed of multiple distributed generators and energy storage system. In this paper, the functions of PCS are defined and 10[kW] PCS for PV and BESS are developed. To apply PCSs to Microgrid, this paper presents a 3-phase inverter with the decoupling current controller, voltage controller and DPLL control system. PCSs were applied to 120[kW] pilot plant and its performance tests were carried out. Test results of PCS at each operation mode show stable in Microgrid.

다양한 형태의 조명(형광등) 전력제어 실증시험을 통한 비용효과적인 전력수요관리방법 도출 (A Study on the Cost Effective DSM Method for Lighting Power Control through Pilot Test Based on Pre-Verified Methodologies)

  • 양승권;김대영
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.7-13
    • /
    • 2013
  • The portion of lighting power consumption for our country is up to 20~30% of the total amount. Currently, most of the DSM(Demand side management) of lighting power is delivered in supply of high efficient lighting to customers. On the contrary, applications of lighting power to power load leveling are still rare. In this paper, the simulations for various control types of lighting power for load leveling are tried, and we obtained the cost effective and optimal control method through that. This simulation was executed in test office with fluorescent light by us based on applying 8 control types(on, off & dimming), considering customers' satisfaction, for instance, minimum intensity of illumination allowed. According to the result of this test, we found that mixed type(chessboard(on-off) plus dimming control(10%)) is most effective.

전기자동차 구동시스템에서의 유도전동기의 최대효율제어 효과(II) (An Effect of Maximizing Efficiency Control of Induction Motor for Electric Vehicle Drive Systems(II))

  • 최욱돈;김동희;노채균
    • 조명전기설비학회논문지
    • /
    • 제14권5호
    • /
    • pp.74-79
    • /
    • 2000
  • 본 논문에서는 유도전동기의 손실을 고려한 최대 효율제어기법을 전기자동차 구동시스템에 적용하고, 그 효과를 검증하기 위해 최대 효율제어를 적용하였을 때와 기존의 일정자속 제어방식을 적용하였을 경우에 대해 각각 ­미국의 F.T.P-72와 E.P.A의 HWFET(Highway Fuel Effciency Test)에서 정한 시내 주행모드(LA-4 Mode) 와 고속 주행 모드에서의 주행시험을 통해 그 결과를 비교 제시하였다. 또한 시험을 통해 전기자동차의 주행거리 증대를 위해 최대 효율제어 적용시 효과를 검토하였다.

  • PDF

신경망을 이용한 판온예측모델내 공정상수 설정 방법 (A Computing Method of a Process Coefficient in Prediction Model of Plate Temperature using Neural Network)

  • 김태은;이해영
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.51-57
    • /
    • 2014
  • This paper presents an algorithmic type computing technique of process coefficient in predicting model of temperature for reheating furnace and also suggests a design method of neural network model to find an adequate value of process coefficient for arbitrary operating conditions including test conditons. The proposed neural network use furnace temperature, line speed and slab information as input variables, and process coefficient is output variable. Reasonable process coefficients can be obtained by an algorithmic procedure proposed in this paper using process data gathered at test conditons. Also, neural network model output equal process coefficient under same input conditions. This means that adquate process coefficients can be found by only computing neural network model without additive test even if operating conditions vary.