• Title/Summary/Keyword: Installation Effect

Search Result 1,466, Processing Time 0.022 seconds

An Experimental Study on Flexural Behavior of RC Beams Strengthened with Hi-Strength Bars(3) (고장력 인장봉으로 보강된 RC 보의 휨 거동에 관한 실험적 연구(3))

  • Shin, Kyung-Jae;Kim, Yoon-Jung;Moon, Jeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.351-358
    • /
    • 2007
  • Unlike external bonded steel plate or carbon fiber, the external unbonded strengthening using hi-strength bar has some advantages in speed and simplicity of installation. It is not required surface preparations and not affected by environmental conditions. A set of nine laboratory tests on RC beams strengthened using the hi-tension bars are reported. Anchoring pin developed in former research is installed at the end of beam to connect the hish-tension bar to RC beam. The test results strengthened by hi-tension bars are compared with those of non-strengthened specimens. The main test parameters are the cross-sectional area of the high-tension bar, distance of stirrups and condition of supports. Test results show that the beams reinforced are superior to reference specimens, especially for the strength and deformation capacity. Also, shear resisting effect of hi-strength bar can be confirmed in the specimens which have lack of stirrups.

Nonlinear stability of the upper chords in half-through truss bridges

  • Wen, Qingjie;Yue, Zixiang;Liu, Zhijun
    • Steel and Composite Structures
    • /
    • v.36 no.3
    • /
    • pp.307-319
    • /
    • 2020
  • The upper chords in half-through truss bridges are prone to buckling due to a lack of the upper transverse connections. Taking into account geometric and material nonlinearity, nonlinear finite-element analysis of a simple supported truss bridge was carried out to exhibit effects of different types of initial imperfections. A half-wave of initial imperfection was proved to be effective in the nonlinear buckling analysis. And a parameter analysis of initial imperfections was also conducted to reveal that the upper chords have the greatest impact on the buckling, followed by the bottom chords, vertical and diagonal web members. Yet initial imperfections of transverse beams have almost no effect on the buckling. Moreover, using influence surface method, the combinatorial effects of initial imperfections were compared to demonstrate that initial imperfections of the upper chords play a leading role. Furthermore, the equivalent effective length coefficients of the upper chord were derived to be 0.2~0.28 by different methods, which implies vertical and diagonal web members still provide effective constraints for the upper chord despite a lack of the upper transverse connections between the two upper chords. Therefore, the geometrical and material nonlinear finite-element method is effective in the buckling analysis due to its higher precision. Based on nonlinear analysis and installation deviations of members, initial imperfection of l/500 is recommended in the nonlinear analysis of half-through truss bridges without initial imperfection investigation.

A Design of Embedded LED Display Board Module and Control Unit which the Placement of Pixels is Free (픽셀 배치가 자유로운 임베디드 LED 전광판 모듈 및 제어장치 설계)

  • Lee, Bae-Kyu;Kim, Jung-Hwa
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.135-141
    • /
    • 2013
  • In this paper, we installed three high brightness red, green, and blue LED in one socket and made one pixel unit. And we also developed the full-color display board module and control unit which can express various images such as text, graphics, video image with the combination of pixel units and a number of modules. LED display driver module have a driver circuit within the combination of the RGB pixel dot on unit area. These modules of the existing form can be high priced because of implementation a fixed resolution in specific space and installation space. To overcome these shortcomings, we developed a LED driver and LED pixel modules free in array at random pitch intervals. Display board module of this paper enabled to display smoothly video image which have many data processing quantity through dragging data speed up 36 frames per second. Also there are an effect which is provided more clear image because of improving the flickering of the existing display board.

Design of Measuring System for Insulation Resistance and Humidity in High-Power XLPE Cables in Operation and the Relationship Between Insulation Resistance and Humidity in the Oversheath (운전 중인 고전력 XLPE 케이블의 절연저항과 습도의 측정 시스템 설계 및 방식층 절연저항과 습도의 상관관계)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.179-184
    • /
    • 2016
  • The usual way used by electric power stations to deliver high levels of generated power is via 6.6kV XLPE (or CV) cables. Depending on the manufacturing technique, installation environment, and usage conditions, the deterioration processes of the power cables start from the instant of operation. Cable junctions may break down in three years from the start of operation due to the manufacturing or construction defects. Otherwise they should be in good working order for 20-30 years. When the cable system (the cable itself and cable junctions combined) deteriorates, fire accidents happen due to the dielectric breakdowns. We have invented a device to monitor the deteriorating status of cables at Korean Western Power Co. Ltd. located in Taean, Chungcheongnam-do province. In this paper, we introduce the device hardware. Using the device, we have measured the insulation resistance and humidity in the sheath of the cables. We present, in analysed results, the effect of humidity on insulation resistance in cable sheaths.

A Study on Design and Performance of a Heat pipe for the Application to Solar Collector (태양열 집열기용 열파이프의 구조와 작동 특성에 관한 연구)

  • 임광빈;김철주
    • Journal of Energy Engineering
    • /
    • v.2 no.2
    • /
    • pp.179-186
    • /
    • 1993
  • Heat pipes. applied to a flat plate solar collector, have a long and slender configuration with relatively low heat flux in the evaporator section. Such a heat pipe has a tendency to build-up a liquid pool at the lower part of the evaporator section. and at this pool occurs such complicated phenomena of evaporation and fluid dynamics as superheat, sudden generation of bubble, its likely explosive growth process and flooding, etc. In the present study. we tried to solve these problems by means of adjusting two principal design parameters, the liquid inventory and the installation region of the wick, using 4 heat pipes and 3 thermospheres. The corresponding results can be summarized as follows$\^$1)/. The effective thermal conductances of the heat pipe was greatly improved by eliminating the wick in the adiabatic and condenser sections$\^$2)/. The liquid inventory should be increased by about 40% larger than what is saturated the wick$\^$3)/. In the evaporator section the wick has a favorable effect to reduce both unstable operation by intermittent occurrence of nucleate boiling and response time at the initial start-up process.

  • PDF

Time Series Analysis of the Effect of Ground-source Heat Pumps on Groundwater Characteristics (시계열 분석을 이용한 지열히트펌프 가동에 따른 지하수특성변화 해석)

  • Mok, Jong-Gu;Lim, Hong-Gyun;Jang, Bum-Ju;Park, Yu-Chul;Lee, Jin-Yong
    • The Journal of Engineering Geology
    • /
    • v.21 no.1
    • /
    • pp.35-43
    • /
    • 2011
  • Time series analysis was applied to groundwater level, water temperature, and electrical conductivity data obtained from monitoring wells around ground-source heat pumps at Sangji University of Wonju (standing column well type) and at Jungwon University of Goesan (closed loop type), from 21 May to 12 October 2010. We found large temporal variations in the characteristics of groundwater at Wonju, but only minor variations at Goesan. These results may improve our understanding of the effects of ground-source heat pumps on the characteristics of surrounding groundwater, according to the installation method for the pumps.

Influence Analysis of Temporal Continuity Change of Flow Data on Load Duration Curve (유량자료의 시간적 연속성 변화가 오염부하지속곡선에 미치는 영향 비교 분석)

  • Kwon, Pil Ju;Han, Jeong Ho;Ryu, Ji chul;Kim, Hong Tae;Lim, Kyoung Jae;Kim, Jong Gun
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.394-402
    • /
    • 2017
  • In korea, TMDL is being implemented to manage nonpoint pollution sources as well as point pollution sources. LDC is being used for the planning of TMDL. In order to analyze the water quality using LDC, it is necessary to prepare FDC using the daily flow data. However, only the daily flow data is measured at the WAMIS branch, and 8days flow data and water quality data are measured at the monitoring Networks. So, in many researches, the water quality is being grasped by deriving the LDC using the 8days flow or the daily flow obtained by various methods. These fluctuations may lead to differences in determining whether the target load is achieved. In this study, each LDC was prepared using the 8day flow and the related daily flow. Then, the effect using different flow data on the achievement of target load was compared according to flow conditions. As a result, the difference ratio in the number of overloads under flow condition was showed 19% in high flows, 42% in moist conditions, 49% in mid-range flows, 41% in dry conditions, and 104% in low flows. In the top ten watershed with the highest difference ratio, the flow became lower the difference ration increases. These differences can cause uncertainty in assessing the achievement of target load using LDC. Therefore, in order to evaluate the water quality accurately and reliably using LDC, accurate daily flow data and water quality data should be secured through the installation of national nonpoint measurement network.

Optimal Sensor Placement for Rapid Detecting in Chemical Leak Accident (화학물질의 누출에서 빠른 감지를 위한 센서 배치 최적화)

  • Cho, Jaehoon;Kim, Hyunseung;Kim, Taeok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.66-71
    • /
    • 2016
  • Nowadays, a number of sensors which are placed in industrial complex are monitoring areas involving chemical leak and other faults. However, even in the presence of the sensors, chemical leaks, sometimes involving huge amount of chemicals, continuously led to big losses in the industrial complex. In most industries, sensor installation has been performed using past experience or using senor manufacturers' guideline; which leads to poor performance of the installed sensor grid. Therefore, we investigate an optimal placement methodology of point sensors for rapid detention and response when chemical leaks happen. This research suggests a generalized formulation suitable for the optimized decision making of minimizing number of sensors to be placed and increasing the fraction of covered scenarios under assumption of negligible effect of other structures. The proposed method has been verified for suitable performance for simple leak scenario simulations, by achieving the safety objectives and guaranteeing safe process operations.

A Study on Trapping Efficiency of the Non-point Source Pollution in Cheongmi Stream Using VFSMOD-w (VFSMOD-w 모형을 이용한 청미천 유입 비점오염물 저감효율 연구)

  • Son, Minwoo;Byun, Jisun;Yoon, Hyun-Doug;Jung, Tae-Hwa
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.140-150
    • /
    • 2016
  • This study aims to investigate the effect of vegetation type, length of vegetative filter strip, and rainfall on trapping efficiency of the non-point source water pollution. Numerical experiments are carried out using VFSMOD-w. It is known from this study that the vegetation having the same value of revised Manning roughness coefficient shows the similar trapping efficiency in VFSMOD-w. When the length of vegetative filter strip increases twice, the trapping efficiency increases negligibly small under the same condition of rainfall. From this finding, it is also known that most of sediment are removed within a certain length of vegetative filter strips. It is concluded that the installation of vegetative filter strip is determined under the consideration of the rainfall characteristics, space of vegetation, and length of vegetative filter strip.

A study on the Dynamic Behavior Enhancement of the Korean High-speed Train (고속열차의 주행동특성 개선에 관한 연구)

  • Jeon, Chang-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.81-87
    • /
    • 2017
  • This paper describes the dynamic behavior and enhancement of Korean high-speed trains. The tail vibration reduction method of the yaw damper installation method change, which was derived from previous research, was applied to the running test of high-speed train. In addition, the vibration reduction method for the entire vehicle was derived by a numerical method and its effect was confirmed by a running test. The improved design was applied to the double-deck high-speed train coaches and the commissioning proceeded without problems in dynamic behavior. Sensitivity analysis of the suspension parameters affecting the critical speed of Korean next-generation high-speed trains was performed and four design variables that greatly affected the critical speed were derived. These were in the order of the primary elastic joint x-directional stiffness, the secondary yaw damper series stiffness, the secondary lateral damper damping coefficient, and the carbody damper damping coefficient. By optimizing the design variables, the suspension parameter that improves the critical speed by 23.3% can be used in the commercial designs of Korean next-generation high-speed trains.