• Title/Summary/Keyword: Installation Effect

Search Result 1,466, Processing Time 0.03 seconds

Evaluation on Termite Damage of the Traditional Wooden Building by Non-destructive Methods (비파괴 검사에 의한 전통목조건축물의 흰개미 열화 특성 조사)

  • Son, Dong-Won;Lee, Dong-heub
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.21-29
    • /
    • 2008
  • The deterioration of Korean traditional wooden house located in seoul was estimated. This house was attacked by termite. To estimate damage status of buildings, non-destructive methods were applied. Some of the post needed to be replaced due to low strength, estimated by nondestructive methods. The house was installed with boiler heating facility, to use office and public education. This kind of heating system changed the environmental condition of the wooden house. The termite which attacked the house was classified as Reticulitermes speratus. Because of durability of wooden house effected by environment, control of the environmental condition is essential for maintaining the wooden house. The installation of modern facility to traditional wooden house should not change the traditional structure and do not effect to durability of wooden house.

A case study on the optimal shafting alignment concerning bearing stiffness for 10,100 TEU container carrier (베어링 강성을 고려한 10,100 TEU 컨테이너 운반선의 최적 추진축계 배치에 관한 사례 연구)

  • Lee, Jae-Ung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.185-190
    • /
    • 2016
  • Damages of the main engine aftmost bearing and the after stern tube bearing tend to increase due to misalignment. And as the shafting system becomes stiffer due to the large engine power, whereas the hull structure becomes more flexible due to optimization by using high tensile thin steel plates. And this is the reason that more sophisticated shaft alignments are required. In this study, the optimum shafting alignment calculation was carried out, considering the thermal expansion effect, exploiting the sensitivity index, which indicates the reasonable position of forward intermediate shaft bearing for shaft alignment. and as the main subject in this study, the elastic deformation on intermediate shaft and main engine bearings occurred by vertical load of shaft mass were examined thoroughly and analyzed allowable load of bearings, reaction influence numbers of all bearings. As the result, a reliable optimum shafting alignment was derived theoretically. To verify these results, they were referred to the engine maker's technical information of main engine installation and being used shafting alignment programs of both Korean Register of Shipping and Det Norske Veritas, their reliability were reviewed.

Venturi Effects Induced by the Local Ventilation Fan in Large-Opening Room-and-Pillar Mining Sites (대단면 갱내 국부 선풍기의 벤츄리(Venturi) 효과 연구)

  • Lee, Chang Woo;Nguyen, Van Duc
    • Tunnel and Underground Space
    • /
    • v.24 no.6
    • /
    • pp.464-472
    • /
    • 2014
  • In large-opening room-and-pillar mining sites, particularly without the devices for the ventilation control, the airflow pattern created by the local fan operation is too complicated to quantify and also shows low ventilation efficiency. This study aims at performing a series of CFD analysis for the so-called venturi effects of the local fans; the effects of increasing airflow rate along the axis downstream of fan resulting from increased kinetic energy and subsequently decreased static pressure in the downstream. Effects of the fan type and installation height are compared. 1 vane-axial fan and 2 propeller fans are analyzed for their venturi effects, while the vane-axial fan was installed at the height of 1.0, 1.5 and 2.0m for comparison. The results can be applied to improve the economy and efficiency of local fans for securing better air quality and work environment management.

Buckling Behaviors of Bucket Foundation for Offshore Wind Tower (해상풍력타워용 버켓기초의 좌굴거동)

  • Lee, Gye Hee;Tran, Duc Phu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.3
    • /
    • pp.123-127
    • /
    • 2013
  • In this study, the buckling behaviors during the installation of a bucket foundation for an offshore wind turbine tower were investigated. The objective structure was modeled by using a commercial structural analysis program, and the buckling behavior of the model was estimated as Batdorf's parameter Z in the design code. The surrounding soil conditions and loading condition were applied to the verified analysis model. The effects of parameters such as the longitudinal stiffeners and driven depth were estimated for the buckling capacity. As a result, it was found that the longitudinal stiffeners could drastically increase the buckling capacity in a specific region. In addition, the buckling capacities increased linearly when considering the effect of the surrounding soil.

Inactivation and Filtration of Bioaerosols Using Carbon Fiber Ionizer Assisted Activated Carbon Fiber Filter (탄소섬유 이오나이저를 적용한 활성탄소섬유 필터의 바이오에어로졸 항균 및 집진 성능평가)

  • Kim, Doo Young;Park, Jae Hong;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.6 no.4
    • /
    • pp.185-192
    • /
    • 2010
  • This paper reports that the installation of a carbon fiber ionizer in front of an activated carbon fiber(ACF) filter enhanced the antibacterial efficiency. In addition, the effect of the ionizer on the filtration of bioaerosols is reported. Negative air ions from the ionizer were used as antibacterial agent. The test bacteria(Escherichia coli) were aerosolized using an atomizer and were deposited on the ACF filter media for 10 minutes. E. coli deposited on the filter were exposed to negative air ions for 0, 1, 5 and 10 minutes. Then they were separated from the ACF filter by shaking incubation with nutrient broth for 4 hours. The separated E. coli were spread on nutrient agar plates and incubated at $37^{\circ}C$ for 1~3 days. The antibacterial efficiency of E. coli was measured using a colony counting method. The antibacterial efficiencies of E. coli exposed to negative air ions for 1, 5 and 10 minutes were 14%, 48% and 71%, respectively. The filtration efficiency was evaluated by measuring the number concentration of bioaerosols at the upstream and downstream of the filter media. The increase of filtration efficiency by air ions was 14%, that is similar to the 17% filtration efficiency by none air ions. The ozone concentration was below the detection limit (under 0.01ppm) when the carbon fiber ionizers were on.

Proper Orthogonal Decomposition Analysis of Flow Characteristics in Hybrid Rocket Engine (POD에 의한 하이브리드 로켓 연소실의 유동특성 해석)

  • Park, Charyeom;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.5
    • /
    • pp.383-389
    • /
    • 2014
  • POD analysis has been done to investigate the internal flow characteristics using LES calculation results of hybrid rocket combustion chamber. The special emphasis was put on the change in the mode energy distribution caused by the installation of diaphragm compared to the baseline case. Also the comparison was made to investigate the effect of wall blowing on the changes in the mode energy between the regions near and far from the diaphragm. For baseline case, POD results clearly distinguish the primary mode containing most of flow energy from the rest of flow modes (2-9 mode) depicting small scale modes. Also, the increase in the energy of flow modes 2-5 is responsible for the formation of relatively large scale structures due to diaphragm. In addition, the comparison of mode energy distributions of flow fields with diaphragm shows similar patterns in both wall blowing and no blowing case. This implies that the local increase in regression rate just after the diaphragm is directly associated with the increase in energy distributions of 2-5 modes.

Pullout Capacity of Screw Anchor Piles Using Field Pull-out Tests (현장인발시험을 통한 Screw Anchor Pile의 인발저항특성)

  • Yoo, Chung-Sik;Kim, Dae-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.1
    • /
    • pp.5-16
    • /
    • 2014
  • This paper presents the results of an investigation into the pullout characteristics of screw anchor pile using field pullout tests. A series of field pullout tests were performed on screw anchor piles with different geometric characteristics such as shaft and screw diameters. The results indicated that screw anchor piles exhibited significantly higher pullout capacities compared with the same diameter piles without screw. Also observed is that the set-up effect and the grouting significantly increase pullout capacities, although the magnitude of the increase depends on the ground condition. In addition the applicability of prediction methods for helical pile pullout capacity to screw anchor piles was also examined. The results are presented in such a way that the pullout characteristics of screw anchor piles with different installation conditions can be identified. Practical implications of the findings are discussed.

Evaluation the Impact of Installing a Isolation Valve on Condensate System of Nuclear Power Plan (원자력발전소 복수기 수실 차단밸브 설치 영향 평가)

  • Lee, Sun-Ki
    • Journal of Industrial Convergence
    • /
    • v.18 no.4
    • /
    • pp.15-21
    • /
    • 2020
  • Because there are no isolation valves in condensate system of nuclear power plants, circulating water pump was shutdown for the condenser repair. When circulating water pump was shutdown, power plant output decreased about 45%. These output decreasing can minimize by establishing isolation valves. In this paper, evaluated effect to flow conditions change of condensate system, structural integrity of system, condenser pressure of in case of establish isolation valves to condensate system. Results of the evaluation, the flow rate due to the installation of the isolation valve decreased 0.3% when the valve was fully opened and 4.5% when fully closed. In addition, it was found that the vacuum degree of the condenser decreased with decreasing flow rate, but the integrity of the system was maintained.

A Study on the Effect of School Site Planning Factors Related to School Location on Increase and Decrease of the Number of Students in Korea (학교 입지 계획요소가 학생수 증감에 미치는 영향에 관한 연구)

  • Yoon, Yong-Gi
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.1
    • /
    • pp.20-29
    • /
    • 2017
  • In order to prove the hypothesis that the element of school location planning - the density of development, availability of various private institutes, the location of school, the type of school district, the distance to nearby schools, the existence of communal areas, the pedestrian street, the number of road lanes - affects the increase and decrease of the number of students in the long term, we examined the tendency of the number of long-term (24 years). The results of the analysis are as follows: First, the development factors such as development density, location of school, type of school district, distance from neighboring schools, separation of pedestrians and cars are clearly related. Second, the planning factors such as location of private school and installation of pedestrian-only street seem to be related to each other. Third, the number of road lanes and element of "communal area" is irrelevant. This study is limited to generalization of five new metropolitan cities in the metropolitan area, and it is necessary to further elaborate the analysis factors and evaluation criteria.

Development of a Large 3D printer for Manufacturing Form-Liner and Protective Skin of Concrete Structures

  • Jang, Jungsik;Hong, Kee-Jeung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.3
    • /
    • pp.74-86
    • /
    • 2020
  • This study discussesresearch and development of large-sized 3D printers that can be applied to construction and civil engineering for various designs of protective casing on foam liner for concrete exteriors. The consistent use of concrete represents the current surroundings. However, concrete exteriors in Korea have not considered the regional characteristics, but the concrete has been poured solely for economical aspects for the last decade or two. There are many cases of poor installation and not enough design development projects to correct it. This study was conducted to apply various patterns, regional characteristics, and 3D printing for protective casing design for foam liner to create various designs for the concrete walls. Therefore, we started researching on a large 3D printer, and designed and developed this system. Considering the chronological process, the properties of concrete structures were identified, the application of designs for concrete in Korea and abroad and the 3D printing materials for the protective casing were surveyed and analyzed, and a stereotype was produced in the first year to study designs for the beauty of concrete surfaces. In the second year, images of regional characteristics were gathered, design ideas for regional promotion were derived, virtual images were produced along with design modeling to simulate the appearances, and verify the effect of application and promotion. Finally, in the third year, the 3D printer for concrete foam liner was constantly improved to analyze the 3D printing program and the various library elements to complete an actual large-sized 3D printer.