• Title/Summary/Keyword: Installation Cost

Search Result 1,181, Processing Time 0.032 seconds

Performance of Hygiene Management according to Capacity and Food Cost of Foodservice in Kindergartens (시설 규모 및 급식비에 따른 유치원 급식소 위생 관리 수행도)

  • Kim, Ok-Sun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.24 no.5
    • /
    • pp.680-690
    • /
    • 2014
  • This study investigated the performance of hygiene management according to the capacity and food cost of foodservice in kindergartens as a measure of kindergartens foodservice hygiene management. Dietitians from the education office visited 50 kindergartens under the control of Dongbu District Office of Education during January, 2011. Kindergartens were 11 public and 39 private institutions. Over half of kindergartens (n=27) provided foodservice to 50~99 children. About 21 kindergartens had a foodservice cost per student per day of 2,000 won. Regarding personal hygiene, 'whether to wear an accessory or have a manicure' showed the best performance. 'Whether to have their health examined once every 6 months or keep their health records in 2 years' was rarely performed. For food materials, 'whether to buy food appropriate for the quality control standard of food materials' showed the highest performance. The highest performances for storage management of food materials and handling of food was 'whether to store goods within butlery at intervals more than 30 cm from the ground' and 'whether to heat and cook food more than $74^{\circ}C$', respectively. The highest performance for distribution of food and management of facilities was 'the hygienic management of cooking tools and facilities' and 'the proper installation of air-conditioning, heating and ventilation facilities', respectively. The results of this study show that capacity and food cost had the strongest effects on performance of personal hygiene. Especially, smaller facility size could increase performance of foodservice management.

Optimal Network Design for the Estimation of Areal Rainfall (면적강우량 산정을 위한 관측망 최적설계 연구)

  • Lee, Jae-Hyeong;Yu, Yang-Gyu
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.187-194
    • /
    • 2002
  • To improve the accuracy of the areal rainfall estimates over a river basin, the optimal design method of rainfall network was studied using the stochastic characteristics of measured rainfall data. The objective function was constructed with the estimation error of areal rainfall and observation cost of point rainfall and the observation sites with minimum objective function value were selected as the optimal network. As a stochastic variance estimator, kriging model was selected to minimize the error terms. The annual operation cost including the installation cost was considered as the cost terms and an accuracy equivalent parameter was used to combine the error and cost terms. The optimal design method of rainfall network was studied in the Yongdam dam basin whose raingauge numbers need to be enlarged for the optimal rainfall networks of the basin.

Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System (일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석)

  • Kim, Min-Ji;Do, Sung-Lok;Choi, Jong-Min;Lee, Kwang Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.

Cost-Effectiveness Analysis of Low-Impact Development Facilities to Improve Hydrologic Cycle and Water Quality in Urban Watershed (도시유역의 물순환 및 수질 개선을 위한 저영향개발 시설의 비용 효율 분석)

  • Choi, Jeonghyeon;Kim, Kyungmin;Sim, Inkyeong;Lee, Okjeong;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.3
    • /
    • pp.206-219
    • /
    • 2020
  • As urbanization and impermeable areas have increased, stormwater and non-point pollutants entering the stream have increased. Additionally, in the case of the old town comprising a combined sewer pipe system, there is a problem of stream water pollution caused by the combined sewer overflow. To resolve this problem, many cities globally are pursuing an environmentally friendly low impact development strategy that can infiltrate, evaporate, and store rainwater. This study analyzed the expected effects and efficiency when the LID facility was installed as a measure to improve hydrologic cycle and water quality in the Oncheon stream in Busan. The EPA-SWMM, previously calibrated for hydrological and water quality parameters, was used, and standard parameters of the LID facilities supported by the EPA-SWMM were set. Benchmarking the green infrastructure plan in New York City, USA, has created various installation scenarios for the LID facilities in the Oncheon stream drainage area. The installation and maintenance cost of the LID facility for scenarios were estimated, and the effect of each LID facility was analyzed through a long-term EPA-SWMM simulation. Among the applied LID facilities, the infiltration trench showed the best effect, and the bio-retention cell and permeable pavement system followed. Conversely, in terms of cost-efficiency, the permeable pavement systems showed the best efficiency, followed by the infiltration trenches and bio-retention cells.

Estimation of CO2 Emission and Emission Cost Function of Thermal Power Plants and Application to 5-Bus Sample Power System (화력발전소의 CO2 배출량 및 배출비용 함수산정과 5모선 전력계통 적용사례)

  • Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.13-18
    • /
    • 2008
  • The global warming due to greenhouse gases is now the hottest issue all over the world. The world has been under $CO_2$ war since the Kyoto Protocol was opened for signature on December 11, 1997 in Kyoto, Japan. The Kyoto Protocol now covers more than 164 countries globally as of July 2006. Countries that ratify this protocol commit to reduce their $CO_2$ emissions, or engage in emissions trading. Korea is also expected to obey the Protocol starting in 2013, which will give a serious shock especially to the electric power industry. The power plants burning the fossil fuel produce more than 20 percent of national total $CO_2$ emission. This paper resents the calculation of the amount and cost of $CO_2$ emission w.r.t. generator MW output and its application to power system operation. The $CO_2$ emission function is derived using the input-output coefficients of the thermal power plants. The optimal power system operation considering $CO_2$ emission and its cost is demonstrated on a five-bus sample power system.

The Analysis of Energy Cost Adopting an Electric Residence using Historical Energy Consumption Data (에너지소비 데이터를 이용한 전전화 주택 도입시 에너지 사용량 분석)

  • Lee, Jun-Kyu;Shin, Hee-Sang;Cho, Sung-Min;Lee, Hee-Tae;Jang, Sung-Kyu;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.131-137
    • /
    • 2010
  • Change of the energy used in a house can be separated from LNG, and electric power. The electric power consumption of a house is more increasing than LNG. The interest for electric houses is rising due to energy saving and low carbon emission. Accordingly, the amount of energies and cost are analyzed consumed in a house using cumulative energy consumption. The result of analysis, amount of electric power, is more increase. In comparison, the use volume of city gas is more decrease. In this paper, the use volume of energy resource is analyzed using historical energy consumption data in the past 25 years. In addition, expected electrical power and heating energy is analysed adopting an Electric Residence.

Optimization Models and Algorithm for the Capacitated Facility Location-Allocation Problem (용량제약이 있는 설비의 위치선정 및 수요자 할당문제에 대한 최적화 모형 및 해법)

  • Kang Sung-Yeol;Sohn Jin-Hyeon
    • Journal of Digital Contents Society
    • /
    • v.3 no.2
    • /
    • pp.221-233
    • /
    • 2002
  • In this paper, we present integer programming models and algorithms for the Capacitated Facility Location-Allocation Problem (CFLP). The models and algorithms can be used for the design of logistics networks and for the location of telecommunication facilities. We are given a set of candidate facility installation sites, one type of facility for each candidate site with its capacity and installation cost, a set of customers with their demand requirement, and flow cost for one unit of demand flow from each customer to each candidate site. (CFLP) is to determine the number of facilities for each candidate site and the set of customers which are connected to each site with minimum cost, while satisfying the demand requirement of each customer and constraints imposed on the allocation of customers to facilities. We present two integer programming models for (CFLP), and devise a branch-and-cut algorithm and a branch-and-price algorithm for the problem.

  • PDF

Assessment of Customer Interruption Cost by Regional Groups for Macro Approach (거시적 방법을 이용한 지역별 정전비용 평가)

  • Park, Choong-Yeul;Huh, Chang-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.124-129
    • /
    • 2005
  • Reliability of electric power supply by power system becomes major issue as the electric power industry is recently being regulated. Also a change of environmental condition related to power supply reliability should be considered in the view of power supplier since the competition between energy-industries is strengthen. In other words, because customers may choose other energy source instead of electric power due to an expensive energy charge, enhancing recklessly the reliability of power supply might not be an essential strategy. So to effectively cope with this problem, it is necessary to perceive the reaction of customers against power supply reliability and interruption cost. This paper evaluates the annual interruption costs of customers by regional groups in Korea using a macro approach to cope with these internal and external environment. That is, the each ratio of customer's interruption costs to price of electric power charge is evaluated for public, service, agricultural, fishery, mining, manufactural, and residential consumption by every cities and provinces.

Demolition and Maintenance/Repair Cost Estimation of Road Drop Obstacle for Safety Risk Removal of Anti-tank Defense Facility (대전차 방어시설의 안전위해요소 제거를 위한 낙석 장애물 철거 및 유지보수 비용 산정 연구)

  • Yoo, Yang-Soo;Park, Young Jun;Eun, Hee-Chang;Baek, Jang-Woon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.4
    • /
    • pp.375-382
    • /
    • 2020
  • Rock drop obstacles on major roads in the border area in South Korea has been installed and operated to prevent and block the movement of enemy units. However, the increase in traffic volume due to the development of the border region causes many problems such as road traffic congestion due to rock drop, traffic safety, and impaired urban aesthetics. Therefore, this study aimed to provide guidelines for demolition and replacement facility installation for rock drop obstacles, which are differently applied to each unit, and to suggest the direction of the Ministry of National Defense's policy regarding maintenance cost for necessary rock drop obstacles required for operation. In this study, as part of a guideline study on the removal of rock drop obstacles and the installation of alternative facilities, a standard unit price was suggested for essential rock drop obstacles, so as to be used as judgment data when deciding whether to remove rock drop obstacles.

An Economic Feasibility Study on Fuel Transfer of A Thermal Power Plant Considering CO2 Emission Cost (CO2 배출비용을 고려한 발전소의 연료교체 경제성에 대한 연구)

  • Lee, Sang-Joong;Jeong, Yeong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.125-130
    • /
    • 2009
  • With respect to the goal of achieving at least 50[%] reduction of global emissions by 2050, the G8 leaders agreed to seek to share and adopt it with all Parties to the UNFCCC in the 34th Group of Eight Summit held in Toyako, Japan in July 2008. Korea is also expected to obey the Kyoto Protocol starting in 2013, which will result in a serious shock especially to the electric power industry. The power plants burning the fossil fuel produce more than 20 percent of national $CO_2$ emission. This paper presents an economic feasibility study on fuel transfer for a thermal power plant considering $CO_2$ emission cost. Calculation of the breakeven point for the fuel transfer from LNG to heavy oil of D power plant is demonstrated using the input-output coefficients obtained by the performance test.