• Title/Summary/Keyword: Inside outside test

Search Result 245, Processing Time 0.027 seconds

Long Term Evaluation of UF Membrane process using River-bed Water (복류수를 이용한 한외여과공정의 장기운전 평가)

  • Kim, Chung H.;Lim, Jae L.;Kang, Suk H.;Kim, Su H.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.429-436
    • /
    • 2008
  • Membrane system has been increasingly considered as a safe and cost-effective water treatment process especially in case of small scale water works. This research is a basis of membrane application in water works through a long period test with obtaining operation skills and evaluation of water quality and cost competitiveness. For the research, the UF membrane system was installed in small water treatment plant that uses river-bed water as raw water. The system was consisted of 2 stage membrane and operated in constant flow mode (Flux: 1.5, 1.0, 0.9, 0.6). In each different flux condition, TMP trends were showed better results at lower flux condition. And through the high flux condition test, it is certified that membrane system could deal with breakdown of one stage. Water quality of permeate was satisfied the water quality standards especially turbidity. To know what mainly causes fouling on membrane, the test by membrane with several cleaning agents and EDX analysis have done in lab. Through the tests, ferrous concentration in raw water, backwashing water and membrane surface etc. was high and it causes fouling inside and outside of membrane. So acid cleaning using organic acid such as oxalic acid is necessary in Chemical in Place (CIP). At the economical aspect the electrical cost of membrane system is higher than that of slow sand filtration but labor cost can be reduced by automation. However, the use of labor should be determined considering effectiveness and stability of operation. Because during the operation, there are several breakdown such as electrical shock by lightning, water drop in summer, etc.

Autonomous Mission Management Software Design and Verification Technique for Unmanned Aerial Vehicles (무인기 자율 임무관리 소프트웨어 설계 및 검증 기법)

  • Chang, Woohyuk;Lee, Seung-Gyu;Kim, Yun-Geun;Oh, Taegeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.6
    • /
    • pp.505-513
    • /
    • 2021
  • We propose an autonomous mission management software design and verification technique for unmanned aerial vehicles to autonomously mitigate dynamic situation changes occurred in the inside and outside of an aircraft in compliance with the mitigation priority order. The proposed autonomous mission management software is designed in a modular architecture that consists of concurrently executing multiple threads. To verify it, we suggest three verification steps: 1) software integration by checking the expected request/response messages between the threads for all possible dynamic situation changes; 2) integration test to verify the software functionality; 3) performance test to verify the quantitative software performance. Especially, the software integration test environment is built and utilized to carry out the integration and performance tests.

A study on the characteristics of Micro Pressure wave for the optimum cross-section design in Honam high speed railway (호남고속철도 터널 단면선정을 위한 미기압파 특성 분석에 관한 연구)

  • Kim, Seon-Hong;Mun, Yeon-O;Seok, Jin-Ho;Kim, Gi-Rim;Kim, Chan-Dong;Yu, Ho-Sik
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2008.03a
    • /
    • pp.51-68
    • /
    • 2008
  • When the train enters into a tunnel a high speed, pressure waves are generated inside the tunnel. The pressure waves at propagate in a form of compression wave toward the tunnel exit and a fraction of the compression waves that arrives at the exit of the tunnel are discharged to outside of the tunnel and the remainder is reflected into the tunnel as expansion waves. The compression waves emitted from the tunnel does not radiate in a specific direction but in all directions. If the amplitude of the compression wave is great, it causes noise and vibration, and it is called "Micro-Pressure Wave." "Micro-Pressure Wave" must be considered as a decision for the optimum tunnel cross-section as the amplitude of the compression wave depends on train speed, tunnel length, area of tunnel and train. Therefore, this paper introduces the case study of Micro-Pressure Wave characteristics for determination of tunnel cross section in Honam high speed railway, the pressure inside the tunnel and the micro-pressure waves at tunnel exit were measured at Hwashin 5 tunnel in Kyungbu HSR line. At the same time. a test of train operation model was performed and then the measurement results and test results were compared to verify that the various parameters used as input conditions for the numerical simulations, which were appropriate. Also a model test was performed, in order to analysis of the Micro-Pressure Wave Mitigation Performance by Type of Hood at Entrance Portal.

  • PDF

Proposal for Housing Environment for Single Woman Household through CPTED Guideline - Focusing on Single Woman Household in their Twenties and Thirties Residing in a Single House in Seoul - (CPTED 가이드라인을 통한 여성 1인가구 주거환경 제안 - 서울시 내 단독주택에 거주하는 20~30대 여성 1인가구를 중심으로 -)

  • Kim, Sang-Hoon;Han, Hae-Ryon
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.6
    • /
    • pp.160-168
    • /
    • 2014
  • Five strongest crimes against women has rapidly increased recently, and women' anxiety is also increasing. Especially, women who reside alone in houses show significantly high anxiety. Such social change is increasing necessity of applying CPTED to housing environment of a single woman household. However, there have been less than enough number of researches on application on CPTED to housing environment of single woman household. So, this study would like to suggest housing environment of single woman household through CPTED guideline. With respect to research method, this study surveyed single woman households in their twenties and thirties who reside at single houses in Gwanak Gu, Gangnam Gu, Songpa Gu, and Mapo Gu in Seoul about necessity of CPTED guideline. Based on the survey results, this study conducted frequency analysis and descriptive statistics; and conducted independent sample t-test, one-way ANOVA, and Scheffe's posteriori test, according to demographic characteristics. As a result, differences in the contents of CPTED guideline by the demographic characteristics turned out to be small, generally. Thus, I concluded that suggestion for housing environment according to characteristics is not necessary. Instead, I would suggest contents of CPTED guideline that gained more than 4 points for housing environment. Research results of this study are as follow. First, 'Securing view of inside and outside of the house and controlling access' should be applied to housing environment of single woman households in their twenties and thirties residing in single houses in Seoul. Second, 'Securing view of an alley and improving walking space' should be applied. Third, 'installing CCTV and emergency bell' should be applied. Fourth, 'reinforcing territoriality of space' should be applied.

A Theoretical Framework of Strategic Decision Making Supporting Systems (전략의사결정지원시스템 개발을 위한 이론적 프레임워크에 대한 연구)

  • Kim, Yong Jin;Jin, Seung Hye;Lee, Seung Tae
    • Journal of Digital Convergence
    • /
    • v.10 no.10
    • /
    • pp.97-106
    • /
    • 2012
  • In the past, executive managers made a decision based on personal experience and knowledge due to lack of the appropriate and timely information. With the development of information systems and technologies, efficiency and productivity of business operation has been enhanced. In this study, we propose a system design and architecture blue-print related to strategic decision making support system. The proposed system consists of 3 key parts; individual business feasibility test, business portfolio feasibility test, business portfolio management. The three key parts are comprised of 11 components to generate information and knowledge based on various data input from inside and outside of firm. This system is expected to provide objective and reliable output to users. In addition, the proposed strategic decision support system would help respond to a rapidly changing business environment.

Signal Characteristics of Multi-coil Probe for the Test of Reinforcement Embedded in Concrete (다중 코일에 의한 콘크리트내의 철근 탐지 시 신호 특성)

  • Kim, Young-Joo;Lee, Seung-Seok;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.285-289
    • /
    • 2000
  • This study suggests a rebar detection technique for simultaneous detection of size and cover of embedded reinforcement in concrete. The structure of the probe made in this study is somewhat different from commercial ones. This probe has three sensing coils. Rebar size and cover depth can be evaluated by detecting and analyzing the signal from them. Amplitude and phase variation of each coil in the probe was investigated using an impedance analyzer and the loci of transfer functions of the coils were analyzed. The locus of transfer function from the sensing coil positioned inside excitation coil was simple as well known, but the others from the coils outside excitation coil were not so. Actual experiment on rebar detection was performed with our probe and an eddy current test system for various rebar sizes and depths. The signal shape according to variation of cover depths showed the same tendency with the transfer function loci acquired by impedance analyzer. The different variation pattern of signal enabled to evaluate rebar size and cover depth simultaneously.

  • PDF

Sludge Disposal Analysis of Sanitary Paper Manufacturing Wastewater Treatment Plant (위생용지 생산 제지공장 폐수슬러지의 처리 현황)

  • Jung, Yong-Jun;Lee, Hong-Tae
    • Journal of Wetlands Research
    • /
    • v.15 no.4
    • /
    • pp.471-476
    • /
    • 2013
  • The operating conditions of sludge disposal for sanitary paper manufacturing wastewater treatment plant were monitored on the basis of daily check sheets during the 3 years of operation. Generated wastes were mainly composed of 79% of sludge, 14% of ash, 5% of waste synthetic resin and 2% of etc. Maximum sludge was produced to 233 ton and the average was 113 ton daily, where the primary sludge occupied 85% and 15% for the secondary sludge. The concentration of coagulant for sludge dewatering was extremely exceeded and the additional experiment such as jar-test was required for the establishment of proper dosage. Presently, the generated sludges were partially treated outside and were also partly handled inside. In the future, most sludges will be expected to be treated to recycling material for the iron industry.

A Study on Resisting Force of H-Shaped Beam Using Glass Web Plate (유리 웨브를 사용한 H형 합성보의 내력에 관한 연구)

  • Son, Ki-Sang;Jeon, Chang-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.3 s.75
    • /
    • pp.73-80
    • /
    • 2006
  • Generally beam design depends on the yielding and maximum strength of each member varying with its section shape. Web plate of H-shape beam has not been substituted with glass plate, because it is known that its strength and heat properties are different and it is limited to substitute the existing steel web with glass element. Ceiling height of each room should be decreased with more than 60-80cm due to the beam. Differently from this condition, glass web beam has a good point to see through it and sunshine can be penetrate into the other size especially when it is installed as of outside wall. And also, it can be safer due to controlling room inside easier, if the strength is applicate. This study is to show some applicability after finding out the properties using the test. The test members with a size of $1,600{\times}200{\times}300{\times}9mm$ being SS41 rolled steel having THK 9mm flange while having 8,10mm and reinforced glass 12mm thickness is bonded with epoxy bond under the condition of temperature $28^{\circ}C$, humidity 50%, bonding power 24Mpa. It is show reinforced glass has 5 times of fracture stress more than the common glass but $50{\sim}150%$ difference between these 2 kinds of glass was shown. Reinforce glass did not support the original upper flange after fracture but the common glass did the upper flange after unloading. Generally reinforced glass is stronger than the common one but the common glass having a part of crack on it, compared with reinforced glass having the overall fracture could be more useful in case of needing ductility.

An Experimental Study on the Precast Segmented PSC Girder with I-Shape and Box-Shape Cross-Section (I형 단면과 BOX형 단면을 갖는 프리캐스트 분절 PSC 거더의 실험적 연구)

  • Kim, Sun-Hee;Lee, Seng-Hoo;Park, Joon-Seok;Cheon, Jinuk;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.8-16
    • /
    • 2015
  • Prestressed concrete (PSC) is a method in which prestressed tendon is placed inside and/or outside the reinforced concrete member and the compressive force applied to the concrete in advance to enhance the engineering properties of concrete member which is weak under tension. In this paper we suggested the precast PSC girder assembled with segments of portable size and weight at the factory. The segments of precast PSC girder will be delivered and assembled as a unit of PSC girder at the site. Consequently, we suggested new-type of precast segmented PSC girder with different shapes of segment cross-section (i.e., I-shape, Box-shape). To mitigate the problems associated with the field splice between the segments of precast PSC girder anchor system is attached near the neutral axis of the girder and relatively uniform compression throughout the girder cross-section is applied. Prior to the experimental investigation, analytical investigation on the structural behavior of precast PSC girder was performed and the serviceability (deflection) and safety (strength) of the girder were confirmed. In addition, 4-point bending test on the girder was conducted to investigate the structural performance under bending. From the experimental investigation, it was found that the precast PSC girder spliced with 3 and 5 segments has sufficient in serviceability and safety conditions and it was also observed that the point where the segments spliced has no defects and the girder behaves as a unit.

Thermal Performance Evaluation Monitoring Study of Transparent Insulation Wall System (투명단열 축열벽 시스템의 열성능 평가 실험 연구)

  • Kim, B.S.;Yoon, J.H.;Yoon, Y.J.;Baek, N.C.;Lee, J.S.
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • Various efforts to combine new high-tech materials with solar system have been progressed nowadays in order to improve the performance of the existing passive solar system. TIM(Transparent Insulation Material) replacing the conventional outer building envelope glazing as well as the wall is good example for this trend. TI integrated wall is a thermal mass wall with a special shaped TIM instead of using typical envelope materials The tested TIM type is a small(diameter 4mm and thickness 50mm) capillary tube of Okalux model and cement brick(density 1500kg/m3). The purpose of this study was to analyze the thermal performance through the actual measurements performed in a test cell. This study was carried out to justify the following issues. 1) the impact of Tl-wall over the temperature variations 2) the impact of mass wall surface absorptance over the transient thermal behavior and 3) the impact of thermal mass wall thickness over the temperature variations. Finally, as results indicated that the peak time of room temperature was shifted about one hour early when absorptance of thermal mass wall changed from 60% to 95% for the 190mm thickness thermal mass wall test case. the temperature difference of both surfaces of thermal mass wall surface showed about $23^{\circ}C$ during a day of March for the 380mm thickness thermal mass wall case. However, the thermal mass wall was over-heated by outside temperature and solar radiation in a day of May the temperature difference of both surfaces of thermal mass wall surface was indicated $10^{\circ}C$ and inside temperature was observed more than average 22C.