• Title/Summary/Keyword: Insertion Force

Search Result 139, Processing Time 0.024 seconds

2-D meso-scale complex fracture modeling of concrete with embedded cohesive elements

  • Shen, Mingyan;Shi, Zheng;Zhao, Chao;Zhong, Xingu;Liu, Bo;Shu, Xiaojuan
    • Computers and Concrete
    • /
    • v.24 no.3
    • /
    • pp.207-222
    • /
    • 2019
  • This paper has presented an effective and accurate meso-scale finite element model for simulating the fracture process of concrete under compression-shear loading. In the proposed model, concrete is parted into four important phases: aggregates, cement matrix, interfacial transition zone (ITZ), and the initial defects. Aggregate particles were modelled as randomly distributed polygons with a varying size according to the sieve curve developed by Fuller and Thompson. With regard to initial defects, only voids are considered. Cohesive elements with zero thickness are inserted into the initial mesh of cement matrix and along the interface between aggregate and cement matrix to simulate the cracking process of concrete. The constitutive model provided by ABAQUS is modified based on Wang's experiment and used to describe the failure behaviour of cohesive elements. User defined programs for aggregate delivery, cohesive element insertion and modified facture constitutive model are developed based on Python language, and embedded into the commercial FEM package ABAQUS. The effectiveness and accuracy of the proposed model are firstly identified by comparing the numerical results with the experimental ones, and then it is used to investigate the effect of meso-structure on the macro behavior of concrete. The shear strength of concrete under different pressures is also involved in this study, which could provide a reference for the macroscopic simulation of concrete component under shear force.

Effect of nicotine on orthodontic tooth movement and bone remodeling in rats

  • Lee, Sung-Hee;Cha, Jung-Yul;Choi, Sung-Hwan;Kim, Baek-il;Cha, Jae-Kook;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.51 no.4
    • /
    • pp.282-292
    • /
    • 2021
  • Objective: To quantitatively analyze the effect of nicotine on orthodontic tooth movement (OTM) and bone remodeling in rats using micro-computed tomography and tartrate-resistant acid phosphatase immunostaining. Methods: Thirty-nine adult male Sprague-Dawley rats were randomized into three groups: group A, 0.5 mL normal saline (n = 9, 3 per 3, 7, and 14 days); group B, 0.83 mg/kg nicotine (n = 15, 5 per 3, 7, and 14 days); and group C, 1.67 mg/kg nicotine (n = 15, 5 per 3, 7, and 14 days). Each animal received daily intraperitoneal injections of nicotine/saline from the day of insertion of identical 30-g orthodontic force delivery systems. A 5-mm nickel-titanium closed-coil spring was applied between the left maxillary first molar (M1) and the two splinted incisors. The rate of OTM and volumetric bone changes were measured using micro-computed tomography. Osteoclasts were counted on the mesial alveolar bone surface of the distobuccal root of M1. Six dependent outcome variables, including the intermolar distance, bone volume fraction, bone mineral density, trabecular thickness, trabecular volume, and osteoclast number, were summarized using simple descriptive statistics. Nonparametric Kruskal-Wallis tests were used to evaluate differences among groups at 3, 7, and 14 days of OTM. Results: All six dependent outcome variables showed no statistically significant among group-differences at 3, 7, and 14 days. Conclusions: The findings of this study suggest that nicotine does not affect OTM and bone remodeling, although fluctuations during the different stages of OTM in the nicotine groups should be elucidated in further prospective studies.

An Empirical Study on the Effects of Non-Tariff Barriers on FTAs: Regarding Import Control Measures of the Target Country on Korea's FTA (자유무역협정에 대한 비관세장벽의 효과에 관한 실증연구: 한국의 자유무역협정과 체결 대상국의 수입규제조치에 대하여)

  • Oh, Dae-Hyuck
    • Asia-Pacific Journal of Business
    • /
    • v.12 no.2
    • /
    • pp.187-203
    • /
    • 2021
  • Purpose - The purpose of this study is to analyze the effects of non-tariff barriers on the Free Trade Agreement. Currently, it has achieved significant export effects by signing free trade agreements with many countries in Korea. However, most countries have implemented non-tariff barriers to protect their industries. This study analyzes the effects of non-tariff barriers in counterpart countries that have signed a free trade agreement. Design/methodology/approach - For analysis, first, prior studies were summarized, and second, the current status of free trade agreements and non-tariff barriers were identified. And, based on the current situation, the relationship between non-tariff barriers and export volume was analyzed. The targets of analysis are the United States, China, and Vietnam, which are Korea's three largest exporters. As for non-tariff barriers, anti-dumping tariffs, countervailing tariffs, and emergency import restrictions were analyzed as import regulatory measures. Findings - In the case of the United States, it can be seen that the decline in textiles, steel and electronics sectors is even greater. In the case of China, it can be seen that exports declined after imposing non-tariff barriers in the steel sector. Finally, it can be seen that exports declined after Vietnam implemented a non-tariff barrier on the steel sector. It was found that non-tariff barriers offset the effects of the Free Trade Agreement. Research implications or Originality - Currently, Korea has free trade agreements with numerous countries. However, after the free trade agreement entered into force, the number of annual average import regulation investigations for Korean products is on the rise. In the end, the implementation of non-tariff barriers is offsetting the effects of free trade agreements. Therefore, when signing a free trade agreement, it is necessary to thoroughly prepare for import regulatory measures such as the insertion of provisions of non-tariff barriers.

Biomechanical comparison of bone staple techniques for stabilizing tibial tuberosity fractures

  • Kyu-Tae Park;Min-Yeong Lee;Hwi-Yool Kim
    • Korean Journal of Veterinary Research
    • /
    • v.63 no.3
    • /
    • pp.24.1-24.6
    • /
    • 2023
  • This study compared the biomechanical properties of bone-stapling techniques with those of other fixation methods used for stabilizing tibial tuberosity fractures using 3-dimensionally (3D)-printed canine bone models. Twenty-eight 3D-printed bone models made from computed tomography scan files were used. Tibial tuberosity fractures were simulated using osteotomy. All samples were divided into 4 groups. Group 1 was stabilized with a pin and tension-band wire; group 2, with a pin and an 8 mm-wide bone staple; group 3, with 2 horizontally aligned pins and an 8 mm-wide bone staple; and group 4 with a 10 mm-wide bone staple. Tensile force was applied with vertical distraction until failure occurred. The load and displacement were recorded during the tests. The groups were compared based on the load required to cause displacements of 1, 2, and 3 mm. The maximum failure loads and modes were recorded. The loads at all displacements in group 4 were greater than those in groups 1, 2, and 3. The loads at 1, 2, and 3 mm displacements were similar in groups 1 and 3. There was no significant difference between groups 1 and 3. Groups 1 and 4 provided greater maximum failure loads than groups 2 and 3. Failure occurred because of tearing of the nylon rope, tibial fracture, wire breakage, pin bending, and fracture around the bone staple insertion. In conclusion, these results demonstrate that the bone-stapling technique is an acceptable alternative to tension-band wire fixation for the stabilization of tibial tuberosity fractures in canine bone models.

Three Dimensional Finite Element Analysis on Stress Distribution According to the Bucco-lingual Inclination of the Implant Fixture and Abutment in the Mandibular Posterior Region (하악 구치부에서 임플란트 고정체와 지대주의 협설 기울기에 따른 응력분포에 관한 삼차원 유한요소 분석)

  • Lee, Hyun-Sook;Kim, Ji-Youn;Kim, Ye-Mi;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.371-392
    • /
    • 2011
  • The purpose of this study was to comparatively analyze the stress distribution according to the inclinations of abutments and angulations of the implant fixtures under occlusal loading force. Three study models with straight and $15^{\circ}$ and $25^{\circ}$-angled abutments were prepared following the insertion of Implants parallel to the long axis of the tooth. Additional two experimental models were fabricated with $15^{\circ}$ and $25^{\circ}$ fixture inclinations. Using ANSYS 11, a finite element analysis program, the magnitudes of stress distribution were analyzed. The magnitude of stress under loading was lowest when the load was applied vertically onto the axis of implant. And the magnitude of stress under compound(vertical+oblique) loading was increased as the inclination of implant abutment and fixture was increase. But, the distribution of stress was different as the loading conditions, because of the horizontal offset. As the offset between the axis of loading and the central axis of the implant increased, the stress was increased.

Effect of Suprabulge Clasp and Infrabulge Clasp on the Mobility of Abutment Teeth for Distal Extension Removable Partial Dentures (유리단 국소의치에서 Suprabulge Clasp와 Infrabulge Clasp가 지대치 동요에 미치는 영향에 관한 연구)

  • Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.39-45
    • /
    • 1981
  • Distal-extension removable partial dentures have long been implicated in the increase in mobility and the destruction of the supporting structures of the primary abutment teeth. Various clasping systems have traditionally been used to retain distal extension removable partial dentures, and other designs have been proposed to minimize torquing forces on the abutment teeth. Most recent studies investigating the effects of removable partial dentures on abutment teeth have been performed in it laboratory setting. Results obtained from in vitro research have given dentists insight into removable partial denture design, but laboratory test model cannot be constructed that simulates actual functional or parafunctiona1 movements and forces. The purpose of this study was to clinically evaluate the degree of tooth mobility produced by two clasping systems (suprabulge type and infrabulge type) used for distal extension removable partial dentures. Akers clasp and R.P.I. system were selected for the evaluation, and four patients required a distal extension removable partial denture on the mandibular arch were selected for participation in the study. Two partial dentures were constructed in the same condition expect the design of clasp. All abutments in the study were mandibular first or second premolars. Measurements of mobility were made with a research tool designed by $M\"{u}hlemann$. This instrument, periodontometer, measures tooth mobility in the mouth by means of a dial gauge accurated to 0.01mm when the tooth is stressed with a force meter. Lingual and buccal deflection of abutment tooth was measured using buccal and lingual pressure. The amount of force applied was 500gm. Tooth mobility tests were made at four key stages; 1. Before insertion of the first removable partial denture, baseline mobility was establsihed. 2. After wearing of the first prosthesis, measurement was made at weekly intervals for 4 weeks. 3. The removable partial denture was then taken from the patient, and tooth mobility was measured again at weekly intervals until the patient's established baseline mobility had returned. 4. The second prosthesis of different clasp design was worn for a month and evaluated in the same manner as the first. The sequence of placement of clasping system was alternated between patients. The following results were obtained from this study; 1. The mobility of abutment tooth increased during the initial stage of wear and returned to baseline mobility after removal of removable partial dentures. 2. The mobility of abutment tooth showed no difference between Akers clasp and I-bar clasp during the 4-week test period. 3. All teeth tested showed greater mobility toward the buccal than the lingual direction.

  • PDF

The effect of early loading on the direct bone-to-implant surface contact of the orthodontic osseointegrated titanium implant (교정력이 골유착성 티타니움 임프란트의 초기 고정에 미치는 영향에 관한 실험적 연구)

  • Chung, Kyu-Rhim;Lee, Sung-Ja
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.173-185
    • /
    • 2001
  • The orthodontic osseointegrated titanium implant, a kind of intraoral skeletal anchorage can be an alternative to tooth-borne anchorage, in case that the conventional tooth-borne anchorage is not available or the anchorage is critical. This study was conducted to elucidate the effect of early loading on the osseointegration of the orthodontic titanium implant and the healing process of the impaired bone at the site of implant after removing it. In two adult beagle dogs24 osseointegrated titanium implants were inserted into the alveolar bone, with 12 implants placed in each dog. In dog1, 6 out of 12 implants were loaded with 200-300gm of force immediately after placing, and the remaining 6 implants were not loaded for 4weeks. In dog2, all 12 implants had healing period of 4weeks, and then were loaded with 200-300gm of force for another 4weeks. Following an observation period of 4 and 8 weeks, the animals were sacrificed. Then the implants and the surrounding bone of dog1 and dog2 were removed, respectively. Undecalcified sections along the long axis of implant were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features of tissues around implants anchored in dog1, there was no difference between immediately loaded implants and unloaded implants. Immature woven bone was ingrowing into the thread spaces from the original compacta and in direct contact with the implant surface in part. 2. The premature loading just after 4weeks healing period did not halt the progress of the osseointegration between bone and implant surface. The woven bone around the implants was maturing into the lamellar bone which resembled the structure of the original compacta at the end of 8weeks observation period. 3. Most implants with the inflammed surrounding mucosa were lost or mobile. The mobile implants were encapsulated by fibrous connective tissue which separated the implant surface from the bone. 4. The impaired bone at the site of the implant failed to anchor was showing recovery without inflammatory reaction 2weeks after removing, with the immaure woven bone lined by active osteoblasts and osteoid. Based on the results of this study, the integration of this orthodontic implant seemed to be impaired by the inflammation of the tissue surrounding the Implant rather than by early loading on implant, and increased with time lapsed after placing the implant. The use of implant described in this report can be recommended as an orthodontic anchorage unit immediately after insertion under the careful control of orthodontic force applied and plaque.

  • PDF

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.

AN EXPERIMENTAL STUDY ON THE OSSEOINTEGRATION OF THE TI-6AL-4V BEAD COATING IMPLANTS (Ti-6Al-4V 비드코팅 임프란트 시제품의 골유착에 대한 실험적 연구)

  • Woo, Jin-Oh;Park, Bong-Wook;Byun, June-Ho;Kim, Seung-Eon;Kim, Gyoo-Cheon;Park, Bong-Soo;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.52-59
    • /
    • 2008
  • The geometric design of an implant surface may play an important role in affecting early osseointegration. It is well known that the porous surfaced implant had much benefits for the osseointegration and the early stability of implant. However, the porous surfaced implant had weakness from the transgingival contamitants, and it resulted in alveolar bone loss. The other problem identified with porous surface implant is the loss of physical properties resulting from the bead sintering process. In this study, we developed the new bead coating implant to overcome the disadvantages of porous surfaced implant. Ti-6Al-4V beads were supplied from STARMET (USA). The beads were prepared by a plasma rotating electrode process (PREP) and had a nearly spherical shape with a diameter of 75-150 ${\mu}m$. Two types of titanium implants were supplied by KJ Meditech (Korea). One is an external hexa system (External type) and the other is an internal system with threads (Internal type). The implants were pasted with beads using polyvinylalcohol solution as a binder, and then sintered at 1250 $^{\circ}C$ for 2 hours in vacuum of $10^{-5}$ torr. The resulting porous structure was 400-500 ${\mu}m$ thick and consisted of three to four bead layers bonded to each other and the implant. The pore size was in the range of 50-150 ${\mu}m$ and the porosity was 30-40 % in volume. The aim of this study was to evaluate the osseointegration of the newly developed dental implant. The experimental implants (n=16) were inserted in the unilateral femur of 4 mongrel dogs. All animals were killed at 8 weeks after implantation, and samples were harvested for hitological examination. All bead coated porous implants were successfully osseointegrated with peripheral bone. The average bone-implant contact ratios were 84.6 % (External type) and 81.5 % (Internal type). In the modified Goldner's trichrome staining, new generated mature bones were observed at the implant interface at 8 weeks after implantation. Although, further studies are required, we could conclude that the newly developed vacuum sintered Ti-6Al-4V bead coating implant was strong enough to resist the implant insertion force, and it was easily osseointegrated with peripheral bone.

Effects of Intermittent Sciatic Nerve Stimulation on the Soleus and Medial Gastrocnemius Muscle Atrophy in Hindlimb Suspended Rats

  • Park, Byung-Rim;Cho, Jung-Shick;Kim, Min-Sun;Chun, Sang-Woo
    • The Korean Journal of Physiology
    • /
    • v.26 no.2
    • /
    • pp.159-166
    • /
    • 1992
  • The present study was designed to evaluate effects of intermittent electrical stimulation of the sciatic nerve on the atrophic response of antigravity muscles, such as the soleus (slow m.) and medial gastrocnemius (fast m.) muscles. Rats (Sprague-Dawley, 245-255g) were subjected to a hindlimb suspension and divided into three groups : one was with hindlimb suspension (MS) and another with hindlimb suspension plus intermittent electrical stimulation of the sciatic nerve (HS ES). Control group (CONT) was kept free without strain of the hindlimb. After 7 days of hindlimb suspension, the soleus and medial gastrocnemius muscles were cut at their insertion sites, and were then connected to the force transducer to observe their mechanical properties. Optimal pulse width and frequency of electrical stimulation were 0.2ms, 20Hz for the soleus muscle and 0.3ms, 40Hz for the medial gastrocnemius muscle under supramaximal stimulation. Body weight and circumference of the hindlimb were significantly decreased in HS and HS-ES groups compared with the control group. In HS-ES group, however, the weight of the soleus muscle was not different from that in the control group while the weight of the medial gastrocnemius muscle was lower than that in the control group. In HS group, mechanical properties of muscle contraction including contraction time, half relaxation time, twitch tension, tetanic tension, and fatigue index of both muscles were significantly decreased compared with the control group except for twitch tension and tetanic tension of medial gastrocnemius muscle. The degree of atrophy of the soleus muscle in HS group was more prominent than that of the medial gastrocnemius muscle. Twitch tension and fatigue index of the soleus muscle and fatigue index of the medial gastrocnemius muscle in HS-ES group were not different from those of the control group. While mechanical properties of the soleus muscle examined were all significantly increased in HS-ES group compared with HS group, only contraction time and fatigue index of the medial gastrocnemius muscle were significantly increased in HS-ES group. These data indicate that intermittent electrical stimulation may be useful in prevention of muscle atrophy.

  • PDF