• Title/Summary/Keyword: Insertion Force

Search Result 139, Processing Time 0.024 seconds

Online Strain Measurement at Multiple Points on a Rotating Blade with Fiber Bragg Grating Sensors and a Rotary Optical Coupler (광섬유 격자 센서와 회전 광학 커플러를 사용한 회전하는 블레이드 여러 지점에서의 온라인 변형률 측정)

  • Lee, Jong-Min;Hwang, Yo-Ha
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.1
    • /
    • pp.77-82
    • /
    • 2008
  • Strain-gauges have been dominantly used to measure strain at various points on a rotor, however, either a slip ring or telemetry has to be used to send sensor signals to data acquisition instruments at stationary side. Both slip ring and telemetry have numerous inherent problems which force severe limitations in real applications. This paper introduces a new rotor condition monitoring system using FBG(Fiber Bragg Grating) sensors and a rotary optical coupler. A single optical fiber with many FBG sensors is installed on the rotor and an optical dynamic interrogator is installed at stationary side. The sensor signal connection between rotating part and stationary part is made by the rotary optical coupling method which makes use of light's unique characteristic-light travels through space. Broad band light source from the interrogator travels to the optical fiber on the rotor and reflected FBG sensor signals travel back to the optical fiber on stationary side and are connected to the interrogator. Rotary optical coupler's insertion loss change due to rotation is compensated by using a reference sensor installed at the center of the rotor. The proposed system's performance has been successfully demonstrated by accurately measuring strains at 5 points on a blade rotating at high speed.

Development of the Low Insertion force Grommet for Vechicle (차량용 저삽입력 그로멧 개발)

  • Cho, Ju-Cheol;Kim, Young-Gil;Seo, Hyroyuki;Song, Woo-Seung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.628-631
    • /
    • 2009
  • 본 논문에서는 당사인 경신공업(주)와 스미토모전장(주)와의 기술제휴를 통한 신제품 개발 프로젝트를 통하여 진행 한 연구 내용이다. 현재 자동차의 주요 부품 중 하나인 Dash-Grommet는 실외에서 실내부로 직부되는 부분으로 방수성이 주요한 성능이다. 이에 따라 현재 방수성 향상을 위해 볼팅으로 씰링을 하는 구조로서 브라켓트를 적용하고 있으며, 볼팅 툴 사용에 따른 홀 위치가 센터로 이동함에 따라 와이어 하네스 성형성을 위해 프로텍터를 적용하고 있다. 이와 관련하여 작업자의 툴 사용에 따른 산업재해(근골격계)요인 및 원가 상승의 원인이 되고 있다. 이에 본 연구에서는 그로멧 씰링구조를 최적화하여 브라켓트를 삭제시키고, 인간 공학적 구조 검토를 통한 저삽입력 구조의 Dash-Grommet 개발에 그 목적을 두었다. 그로멧 3중 씰링 구조를 이용하여 주요 성능인 방수(침수/살수) 성능에 대한 문제를 해결하였으며, 내부 파이프 구조를 이용하여 와이어를 통한 수분 유입에 대한 수밀 대책이 마련 되도록 하였다. 또한, 돌기부 구조를 이용하여 차량 장착시 판넬 접촉면을 최소화 함으로써 실제차량 장착 작업시 저삽입력을 가능하게 하였으며, 이와 더불어 홈부 구조를 이용하여 차량 장착시 그로멧의 수축을 용이하게 함으로써 새로운 그로멧 삽입 메커니즘을 구현하여 기존 대비 40~50%의 저 삽입력 그로멧을 개발할 수 있었다.

  • PDF

A Study on the Drag Reduction Effect and Heat Transfer Enhancement of Non ionized Surfactant and Water Mixture in a Circular Pipe Flow (비이온계 계면활성제 첨가수에 대한 관내 유동저항 감소 및 열전달 촉진에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.552-557
    • /
    • 2007
  • This paper has dealt with the effect of non ionized surfactant and water mixture on drag reduction and heat transfer enhancement in a circular pipe flow with experimentally. The test section was consisted of stainless steel pipe with inside diameter of 16mm. The wire coil was used to increase heat transfer in a pipe and the on ionized surfactant(Oleyl Dihydroxyethyl Amino Oxide, ODEAO) was used to reduce the drag force of water mixture with surfactant. The main parameters of this experiment were diameter and pitch of wire coil and the ratio of test section length and horizontal wire coil length. In this experiment, the acquired results were 1) Drag reduction effect existed in this ODEAO-water mixture, 2) Friction factor and heat transfer were increased with insertion the heat transfer enhancement coil, 3) With increasing of pitch ratio, heat transfer was decreased, and 4) Heat transfer was decreased by the decreasing of inserting coil diameter.

A Study on the AlN Thin Film on A1$_2$O$_3$ Substrate Prepared by Reactive RF Magnetron Sputtering System for SAW Device Application (A1$_2$O$_3$기판위에 반응성 RF 마그네트론 스퍼터로 증착한 AlN 박막의 SAW소자 응용에 관한 연구)

  • 고봉철;손진운;김경석;엄무수;남창우;이규철
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.7
    • /
    • pp.288-292
    • /
    • 2003
  • AlM thin film has been deposited on A1$_2$O$_3$ substrate by reactive radio frequency(RF) magnetron sputtering method under various operating conditions such as working pressure, fraction of nitrogen partial pressure, and substrate temperature. Scanning Electron Microscope(SEM), X-ray Diffraction(XRD), and Atomic Force Microscope(AFM) have been measured to find out structural properties and preferred orientation of AlN thin films. SAW velocity of IDTs/AlN/Si structure was about 5038[㎧] at the center frequency of 251.9[MHz] and insertion loss was measured to be relatively low value of 35.6[dB]. SAW velocity of IDTs/AlN/A1$_2$O$_3$ structure was improved to be about 5960[㎧] at the center frequency of 296.7[MHz].

Biomechanical Test for Repair Technique of Full-thickness Rotator Cuff Tear

  • Lim, Chae-Ouk;Park, Kyoung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.51-58
    • /
    • 2016
  • The arthroscopic rotator cuff repair is now considered a mainstream technique with highly satisfactory clinical results. However, concerns remain regarding healing failures for large and massive tears and high revision rate. In recent decades, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. The focus of biomechanical test in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. Recent studies have shown that a transosseous tunnel technique provides improved contact area and pressure between rotator cuff tendon and insertion footprint, and the technique of using double rows of suture anchors to recreate the native footprint attachment has been recently described. The transosseous equivalent suture bridge technique has the highest contact pressure and fixation force. In this review, the biomechanical tests about repair techniques of rotator cuff tear will be reviewed and discussed.

An Ultra Wideband, Novel and Reliable RF MEMS Switch

  • Jha, Mayuri;Gogna, Rahul;Gaba, Gurjot Singh;Miglani, Rajan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.4
    • /
    • pp.183-188
    • /
    • 2016
  • This paper presents the design and characterization of wide band ohmic microswitch with an actuation voltage as low as 20~25 V, and a restoring force of 14.1 μN. The design of the proposed switch is primarily composed of an electrostatic actuator, bridge membrane, cantilever (beam) and coplanar waveguide, suspended over the substrate. The analysis shows an insertion loss of −0.002 dB at 1GHz and remains as low as −0.35 dB, even at 100 GHz. The isolation loss of the switch is sustained at −21.09 dB at 100GHz, with a peak value of −99.58 dB at 1 GHz and up-state capacitance of 4 fF. To our knowledge, this is the first demonstration of a series contact switch, which works over a wide bandwidth (DC-100 GHz) and with such a high and sustained isolation, even at high frequencies and with an excellent figure of merit (fc=1/2.pi.Ron.Cu= 39.7 THz).

Development of a injection molding automation system of busbar insert for the electric vehicle (전기 자동차 부스바 인서트 사출 자동화 시스템 개발)

  • Jong-Su Kim
    • Design & Manufacturing
    • /
    • v.18 no.2
    • /
    • pp.35-40
    • /
    • 2024
  • Injection molding is a process widely used across various industries for molding plastics, and it is the most commonly applied process in root industries utilizing molds. Among the different types of injection molding, insert injection molding, where busbars are used as inserts, is increasingly being applied in the electric vehicle industry. However, currently, the insert injection molding process is manually performed, with workers placing insert components by hand before injection molding. This results in issues related to productivity, safety, and quality. Additionally, there is a growing demand for automation of such production lines due to hazardous working conditions, economic difficulties in the manufacturing industry, and the decline in the labor force caused by an aging population. This study focuses on the application of an automated system for the insert injection molding process used in electric vehicles. The development of an automated system for the transport and insertion of insert components, as well as the inspection and stacking processes after injection, has resulted in over a 25% improvement in productivity and more than a 27% reduction in defect rates.

Histologic and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants (Self drilling과 Self-tapping microscrew implants의 조직학적 및 생역학적인 비교)

  • Park, Hyo-Sang;Yen, Shue;Jeoung, Seong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.295-307
    • /
    • 2006
  • Objective: The purpose of this study was to compare the histological and biomechanical characteristics of self-tapping and self-drilling microscrew implants. Methods: 112 microscrew implants (56 self-drilling and 56 self-tapping) were placed into the tibia of 28 rabbits. The implants were loaded immediately with no force, light (100 gm), or heavy force (200 gm) with nickel-titanium coil springs. The animals were sacrificed at 3- and 5-weeks after placement and histologic and histomorphometric analysis were performed under a microscope. Results: All microscrew implants stayed firm throughout the experiment. There was no significant difference between self-drilling and self-tapping microscrew implants both in peak insertion and removal torques. Histologic examinations showed there were more defects in the self-tapping than the self-drilling microscrew implants, and newly formed immature bone was increased at the interface in the self-tapping 5-week group. There was proliferation of bone towards the outer surface of the implant and/or toward the marrow space in the self-drilling group. Histologically, self-drilling microscrew implants provided more bone contact initially but the two methods became similar at 5 weeks. Conclusion: These results indicate the two methods can be used for microscrew implant placement, but when using self-tapping microscrew implants, it seems better to use light force in the early stages.

Influence of Implant Designs on Initial Stability (임플란트의 형태가 초기 안정성에 미치는 영향)

  • Cho, Jae-Myoung;Kim, Chang-Seop;Yun, Mi-Jung;Jeong, Chang-Mo;Seo, Seung-U
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.47-57
    • /
    • 2010
  • An undisturbed healing process without micromotion at the implant-bone interface is essential for achievement of osseointegration of dental implant. Therefore, initial stability was advocated as prerequisite for successful clinical outcome. Adequate bone quality and quantity were important to achieve initial stability and to prevent early failures. However there were few published data available regarding the effect of design change in implant geometry on initial stability of the implants. The purpose of the current study was to assess the initial stability of various designs of implants when placed into artificial bone materials of varying qualities and shapes of insertion holes. Within the scope of this study, the following results were drawn. Bone quality was major importance to achieve initial stability. Initial stability was higher on GS II which had additional design feature of double thread. With a tapered design of implant such as GS III showed a higher initial stability than straight one. An insertion hole with the similar shape of implant would lead to reduce a compression force on cortical bone and enhance a bone anchorage on cancellous bone.

The skeletal cortical anchorage using titanium microscrew implants (Titanium microscrew implant를 이용한 skeletal cortical anchorage)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.699-706
    • /
    • 1999
  • Anchorage plays an important role in orthodontic treatment. Endosseous implants may be considered adequate firm anchorage. However, clinicians have hesitated to use endosseous implants as orthodontic anchorage because of limited implantation space, high cost, and long waiting period before osseointegration occurs. Recently, some clinicians have tried to use titanium miniscrews and microscrews in treatment due to their many advantages such as ease of insertion and removal, low cost, immediate loading, and the ability to place microscrews in any area of alveolar bone. The author treated a case with skeletal cortical anchorage using titanium microscrew implants. During six months of orthodontic force application from skeletal cortical anchorage, the author could get 4 mm bodily retraction and intrusion of upper anterior teeth. The most outstanding result was a 1.5 mm posterior refraction of the upper posterior teeth. The titanium microscrew implants had remained firm and stable throughout treatment. These results indicate that skeletal cortical anchorage might be a very good option.

  • PDF