• Title/Summary/Keyword: Input power decrease

Search Result 125, Processing Time 0.022 seconds

Development of Boost Type Bidirectional ZCS DC/DC Converter For EV of Transformer Series Construction (변압기 직렬구조의 EV용 승압형 양방향 ZCS DC/DC 컨버터 개발)

  • Choi, Jung-Sik;Park, Byung-Chul;Chung, Dong-Hwa;Song, Sung-Gun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.37-46
    • /
    • 2013
  • This paper proposes the boost type bidirectional zero current switching(ZCS) DC/DC converter of transformer series construction for electric vehicle operation using low voltage battery. This converter can high boost through the double voltage circuit and series construction of output part using two converters. This converter system has the advantages that bidirectional power transfer is excellent, size and making of transformer because of this converter keeps the transformation ratio to 1:1. Proposed DC/DC converter uses the ZCS method to decrease the switching loss. By replacing reactance ingredients of L-C resonance circuit for ZCS with leakage inductance ingredients of high frequency transformer and half-bridge capacitor it reduces system size and expense because of not add special reactor. It can confirm to output of high voltage to operate the electric vehicle with low voltage of input and operation of ZCS in all load region through the result of PSIM simulation and experiment.

Research for the Effect of Accumulator and the High Frequency-Hydraulic System of Frequency Characteristics by Experimental Method (고주파 유압시스템의 주파수 특성과 축압기 효과의 실험적 연구)

  • Park, Nam-Eun;Kim, Jae-Soo;Kim, Yang-Soo;Kim, Jong-Rok;Rho, Hyung-Woon;Jeon, Seung-Bae;Na, Hong-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.3 s.20
    • /
    • pp.51-57
    • /
    • 2003
  • Characteristics of the high frequency pulsatile flow have been investigated experimentally to understand the flow phenomena in the hydraulic system. One axis fatigue test bed, which is widely used for automobile field test, is used. Four pressure transducers, an amplifier and a A/D convertor are used to obtain the high frequency pulsatile pressure waveform in hydraulic system. The characteristics of frequency are analyzed by power spectrum method. According to the variations of pump input pressure and actuator acceleration frequency, the pressure is measured with or without an accumulator. The amplitude of pressure with accumulator is very lower than those without accumulator due to absorbing function of accumulator. As the frequency of actuator acceleration is increased, the effect of accumulator become very important to decrease the amplitude of pulsatile pressure waveform with high frequencies.

Calculation of Transverse Vibration of Ship`s Propulsion Shaftings by the Finite Element Method (有限要素法에 의한 推進軸系의 광振動計算에 관한 硏究)

  • Jeon, Hio-Jung;Kim, Hi-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.2-18
    • /
    • 1979
  • Due to increasing ship dimensions and installed propulsive power, resonance frequencies of the propeller shaft system tend to decrease and they can appear in some cases within the operating range of the shaft revolution. For calculation of transverse shaft vibrations, various methods have been proposed but as they are mainly for approximate calculation, no contented results are obtained. For fairly accurate estimation of resonance frequencies in the design stage, one can use transfer matrix method of the finite element method and former is rather prefered in ordinary cases. In this study, the finite element method which is utilized for calculation of the propulsion shaft alignment, is introduced to derive the vibration equation of the ship's propulsion shaftings. The digital computer program is developed to solve the above equation, and the details of preparing the input data are described. The method presented in the underlying report was applied to the shafting of ship which has a lignumvitae bearing to verify its reliability and the results of calculation and those of the measurements on rotating shaft show a good agreement. Calculating methods of exciting of forces and damping forces are also discussed for future work.

  • PDF

Full-Wave Rectifier with Vibration Detector for Vibrational Energy Harvesting Systems

  • Yoon, Eun-Jung;Yang, Min-Jae;Park, Jong-Tae;Yu, Chong-Gun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.3
    • /
    • pp.255-260
    • /
    • 2016
  • In this paper, a full-wave rectifier (FWR) with a simple vibration detector suitable for use with vibrational energy harvesting systems is presented. Conventional active FWRs where active diodes are used to reduce the diode voltage drop and increase the system efficiency are usually powered from the output. Output-powered FWRs exhibit relatively high efficiencies because the comparators used in active diodes are powered from the stable output voltage. Nevertheless, a major drawback is that these FWRs consume power from the output storage capacitor even when the system is not harvesting any energy. To overcome the problem, a technique using a simple vibration detector consisting of a peak detector and a level converter is proposed. The vibration detector detects whether vibrational energy exists or not in the input terminal and disables the comparators when there is no vibrational energy. The proposed FWR with the vibration detector is designed using a $0.35-{\mu}m$ CMOS process. Simulation results have verified the effectiveness of the proposed scheme. By using the proposed vibration detector, a decrease in leakage current by approximately 67,000 times can be achieved after the vibration disappears.

Nitrogen Budget of South Korea Including Gaseous Nitrogen Oxides from 2012 to 2014 (기체상 질소산화물을 포함한 2012~2014년도 대한민국 질소수지 연구)

  • Lee, Hanuk;Oa, Seyeon;Park, Jae-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.4
    • /
    • pp.49-59
    • /
    • 2017
  • This study estimated the nitrogen budget, including gaseous nitrogen oxides ($NO_x$), of South Korea in 2012~2014. The nitrogen budget was classified into three categories: agricultural and livestock, forest, and city. To estimate the nitrogen budget, several input and output parameters were investigated, including deposition, fixation, irrigation, chemical fertilizer use, compost, fuel, denitrification, volatilization, runoff, crop uptake, leaching, and $NO_x$ emissions. The annual nitrogen inputs from 2012 to 2014 were 6,202,828, 6,137,708, and 6,022,379 ton/yr, respectively. The corresponding annual nitrogen outputs were 1,393,763, 1,380,406, and 1,360,819 ton/yr, respectively, signifying a slight decrease from 2012 to 2014. $NO_x$ was the parameter contributing to the nitrogen budget to the greatest extent. The annual ratios of $NO_x$ emissions by vehicles, power plants, and businesses were 0.31, 0.31, and 0.30 in 2012, 2013, and 2014, respectively. A change in government policy that prohibited the disposal of livestock manure and sewage sludge in the ocean from 2012 affected nitrogen budget profile. As a result, the ocean disposal ratio completely diminished, which differs from previous studies.

Uncertainty Analysis of Dynamic Thermal Rating of Overhead Transmission Line

  • Zhou, Xing;Wang, Yanling;Zhou, Xiaofeng;Tao, Weihua;Niu, Zhiqiang;Qu, Ailing
    • Journal of Information Processing Systems
    • /
    • v.15 no.2
    • /
    • pp.331-343
    • /
    • 2019
  • Dynamic thermal rating of the overhead transmission lines is affected by many uncertain factors. The ambient temperature, wind speed and wind direction are the main sources of uncertainty. Measurement uncertainty is an important parameter to evaluate the reliability of measurement results. This paper presents the uncertainty analysis based on Monte Carlo. On the basis of establishing the mathematical model and setting the probability density function of the input parameter value, the probability density function of the output value is determined by probability distribution random sampling. Through the calculation and analysis of the transient thermal balance equation and the steady- state thermal balance equation, the steady-state current carrying capacity, the transient current carrying capacity, the standard uncertainty and the probability distribution of the minimum and maximum values of the conductor under 95% confidence interval are obtained. The simulation results indicate that Monte Carlo method can decrease the computational complexity, speed up the calculation, and increase the validity and reliability of the uncertainty evaluation.

CO2 Emission Structure Analysis of Industrial Sector with Environmental Input-Output Table 2005 (환경산업연관표 2005를 이용한 산업부문의 이산화탄소(CO2) 배출 분석)

  • Kim, Yoon Kyung
    • Environmental and Resource Economics Review
    • /
    • v.20 no.1
    • /
    • pp.1-31
    • /
    • 2011
  • By employing Environmental Input-Output Table 2005, which has 76 intermediate sector and 21 energy sources, this paper analyses the flow of energy demand and $CO_2$ after estimating an induced $CO_2$ emissions from 76 industrial sectors. Index of $CO_2$ intensity($CO_2/GDP$) and other index of $CO_2$ intensity($CO_2/calory$) showed that final demand sector uses more high calory energy source. Intermediate sector used less environmental friendly energy source and emit more $CO_2$ at same calory. Industries those has high induced $CO_2$ emissions are Thermal Power($32.587CO_2-g/Won$), Cement($10.370CO_2-g/Won$), Road Transportation($7.255CO_2-g/Won$), Cokes and Other Coal Products($5.791CO_2-g/Won$), Steam and Hot water supply, Sewage, Sanitary services($4.575CO_2-g/Won$). It is shown that industry such as Iron and Steel which has low $CO_2$ intensity, high backward linkage effect and high forward linkage effect makes high induced $CO_2$ emissions. Environmental load and $CO_2$ emissions in overall economy will decrease when not high $CO_2$ intensity industry but also low $CO_2$ intensity industry makes lower $CO_2$ intensity.

  • PDF

Operation Characteristics of a Plasma Reformer for Biogas Direct Reforming (바이오가스 직접 개질을 위한 플라즈마 수소 추출기 운전 특성 연구)

  • Byungjin Lee;Subeen Wi;Dongkyu Lee;Sangyeon Hwang;Hyoungwoon Song
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.404-411
    • /
    • 2023
  • For the direct reforming of biogas, a three-phase gliding arc plasma reformer was designed to expand the plasma discharge region, and the operation conditions of the plasma reformer, such as the S/C ratio, the gas flow rate, and the plasma input power, were optimized. The H2 production efficiency is increased at a lower specific plasma input energy density, but byproducts such as CXHY and carbon soot are generated along with the increase in H2 production efficiency. The formation of byproducts is decreased at higher specific plasma input energy densities and S/C ratios. The optimized operation conditions are 5.5 ~ 6.0 kJ/L for the specific plasma input energy density and 3 for the S/C ratio, considering the conversion efficiency, H2 production, and byproduct formation. It is expected that the H2 production efficiency will improve with the decrease in fuel consumption in biogas burners because the heat generated from plasma discharge heats up the feed gas to over 500 ℃.

Design of The 10bit 80MHz CMOS D/A Converter with Switching Noise Reduction Method (스위칭 잡음 감소기법을 이용한 10비트 80MHz CMOS D/A 변환기 설계)

  • Hwang, Jung-Jin;Seon, Jong-Kug;Park, Li-Min;Yoon, Kwang-Sub
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.6
    • /
    • pp.35-42
    • /
    • 2010
  • This paper describes a 10 bit 80MHz CMOS D/A converter for wireless communication system. The proposed circuit in the paper is implemented with a $0.18{\mu}m$ CMOS n-well 1-poly 6-metal process. The architecture of the circuit consists of the 4bit LSB with binary decoder, and both the 3bit ULSB and the 3bit MSB with the thermometer decoder. The measurement results demonstrates SFDR of 60.42dBc at sampling frequency 80MHz, input frequency 1MHz and ENOB of 8.75bit. INL and DNL have been measured to be ${\pm}$0.38LSB and ${\pm}$0.32LSB and glitch energy is measured to be 4.6$pV{\cdot}s$. Total power dissipation is 48mW at 80MHz(maximum sampling frequency) with a single power supply of 1.8V.

Performance Improvement of Retrodirective Antenna System using Turbo Equalizer (터보등화기를 이용한 디지털 역지향성 안테나 시스템의 성능 개선)

  • Kim, Bong-Jun;Ryu, Heung-Gyoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.24-30
    • /
    • 2014
  • A digital RDA(Retrodirective Antenna) system is a retransmit system that received signal without prior information turn back by estimated phase of the signal to received direction. The RDA can decrease consumption of power by increase of directivity because signal concentrates on received direction compare to omni-direction antenna which transmit power all direction. Generally, the RDA is known to show better performance than the single-antenna system in multi-path environment. However, the RDA occurs performance degradation in serious ISI channel. In this paper, to solve this problem, we propose retrodirective antenna combined with turbo equalizer combined which can compensate serious ISI channel, we increase the BER performance through proposed retrodirective antenna combined with turbo equalizer in serious ISI channel.