• 제목/요약/키워드: Input power decrease

검색결과 123건 처리시간 0.02초

Efficiency Increase and Input Power Decrease of Converted Prototype Pump Performance

  • Oshima, Masao
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권3호
    • /
    • pp.205-212
    • /
    • 2016
  • The performance of a prototype pump converted from that of its model pump shows an increase in efficiency brought about by a decrease in friction loss. As the friction force working on impeller blades causes partial peripheral motion on the outlet flow from the impeller, the increase in the prototype's efficiency causes also a decrease in its input power. This paper discusses results of analyses on the behavior of the theoretical head or input power of a prototype pump. The equation of friction-drag coefficient for a flat plate was applied for the analysis of hydraulic loss in impeller blade passages. It was revealed that the friction-drag of a flat plate could be, to a certain degree, substituted for the friction drag of impeller blades, i.e. as a means for analyzing the relationship between a prototype pump's efficiency increase and input power decrease.

무손실 스너버를 적용한 고역률, 고효률 AC/DC Boost 컨버터에 관한 연구 (A Study on the High-Power-Factor, High-Efficiency AC/DC Boost Converter with Non-Dissipative Snubber)

  • 배진용;김용;백수현;권순도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.112-115
    • /
    • 2002
  • Previous AC/DC PFC Boost Converter perceives feed forward signal of input and feedback signal of output for average current-mode control. Previous Boost Converter, the quantity of input current will be decreased by the decrease of output current in light load, and also power factor comes to be decreased. Also the efficiency of converter will be decreased by the decrease of power factor. The proposed converter presents the good PFC(Power Factor Correction), low line current hormonic distortions and tight output voltage regulations using non-dissipative snubber. The proposed converter also has a high efficiency by non-dissipative snubber circuit. To show the superiority of this converter is verified through the experiment with a 640W, 100kHz prototype converter.

  • PDF

Input-Series-Output-Parallel Connected DC/DC Converter for a Photovoltaic PCS with High Efficiency under a Wide Load Range

  • Lee, Jong-Pil;Min, Byung-Duk;Kim, Tae-Jin;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.9-13
    • /
    • 2010
  • This paper proposes an input-series-output-parallel connected ZVS full bridge converter with interleaved control for photovoltaic power conditioning systems (PV PCS). The input-series connection enables a fully modular power-system architecture, where low voltage and standard power modules can be connected in any combination at the input and/or at the output, to realize any given specifications. Further, the input-series connection enables the use of low-voltage MOSFETs that are optimized for a very low RDSON, thus, resulting in lower conduction losses. The system costs decrease due to the reduced current, and the volumes of the output filters due to the interleaving technique. A topology for a photovoltaic (PV) dc/dc converter that can dramatically reduce the power rating and increase the efficiency of a PV system by analyzing the PV module characteristics is proposed. The control scheme, consisting of an output voltage loop, a current loop and input voltage balancing loops, is proposed to achieve input voltage sharing and output current sharing. The total PV system is implemented for a 10-kW PV power conditioning system (PCS). This system has a dc/dc converter with a 3.6-kW power rating. It is only one-third of the total PV PCS power. A 3.6-kW prototype PV dc/dc converter is introduced to experimentally verify the proposed topology. In addition, experimental results show that the proposed topology exhibits good performance.

방전Plasma 반응에 의한 NOx의 안전처리에 관한 연구 (A Study on Safety Treatment of NOx by Discharge Plasma Reaction)

  • 최재욱;야마구마 미즈키
    • 한국안전학회지
    • /
    • 제15권2호
    • /
    • pp.92-96
    • /
    • 2000
  • In this experiment, we studied about concentration characteristics of $NO_x$ and generation of ozone in the reactor of corona discharge type by using mixed gas of $NO/N_2$ and $N_2/O_2$. In the case of the initial NO concentration increased, decrease rate of NO concentration was weakened and discharge input power of minimum NO concentration became high. When NO concentration was high, NO decomposition limit was appeared. And NO reduction rate was decreased, when initial NO concentration and discharge input power increased. When discharge input power was 5W, we could know the most proper energy value for treatment of NO. When the concentration of initial NO increased, generation of ozone decreased and in the case of same concentration of NO, according to discharge input power increase, generation of ozone increased.

  • PDF

A Model Predictive Controller for Nuclear Reactor Power

  • Na Man Gyun;Shin Sun Ho;Kim Whee Cheol
    • Nuclear Engineering and Technology
    • /
    • 제35권5호
    • /
    • pp.399-411
    • /
    • 2003
  • A model predictive control method is applied to design an automatic controller for thermal power control in a reactor core. The basic concept of the model predictive control is to solve an optimization problem for a finite future at current time and to implement as the current control input only the first optimal control input among the solutions of the finite time steps. At the next time step, the second optimal control input is not implemented and the procedure to solve the optimization problem is then repeated. The objectives of the proposed model predictive controller are to minimize the difference between the output and the desired output and the variation of the control rod position. The nonlinear PWR plant model (a nonlinear point kinetics equation with six delayed neutron groups and the lumped thermal-hydraulic balance equations) is used to verify the proposed controller of reactor power. And a controller design model used for designing the model predictive controller is obtained by applying a parameter estimation algorithm at an initial stage. From results of numerical simulation to check the controllability of the proposed controller at the $5\%/min$ ramp increase or decrease of a desired load and its $10\%$ step increase or decrease which are design requirements, the performances of this controller are proved to be excellent.

Experimental Study on the Input Coupled type CVT combined a Differential Gear and V-Belt type CVU

  • Kim, Yeon-Su;Park, Sang-Hoon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권1호
    • /
    • pp.43-55
    • /
    • 2001
  • A continuously variable transmission(CVT) mechanism composed of one differential gear unit and one continuously variable unit(CVU) can be classified according to the coupling of CVU and the direction of power flows. The mechanism has many advantages which are the decrease of CVT size, the increase of overall efficiency, the extension of speed ratio range and generation of geared neutral. The CVT mechanism considered here is the input coupled type which combines the functions of a 2K-H I type differential gear unit and a V-belt type CVU. One shaft of the CVU is connected directly to the input shaft and another shaft of it is linked to the differential gear unit. It is shown that some fundamental relations(speed ratios, power flows and efficiencies) for twelve mechanisms previously described are valid by various experimental studies, six of them produce a power circulation and the others produce a power split. Some useful comparisons between theoretical analysis and experimental results are presented. General properties also are discussed, which connect following power flow modes : (a) power circulation mode; (b) power split mode.

  • PDF

최적 범위내에서 WLS인 게이트 수가 최대가 되는 입력 벡터를 이용한 게이트 수정 기법 (A Gate Modification Method Using the Input Vector Maximizes the Number of Gates in WLS within the Optimum Range)

  • 성방현;박혜성;김석윤
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.745-750
    • /
    • 2007
  • In this paper, we propose a new gate modification method using the input vector maximizes the number of gates in WLS within the optimum range of the minimum leakage power. We prove that MLV is not always the optimal solution, and that the leakage power and area can decrease when modifying the gates using the input vector for which the number of gates in WLS is maximized within the optimum range of the minimum leakage power for the circuits applying the IVC technique and gate modification method. Using the proposed method, the gate-level description circuit can be converted to the modified circuit which reduces the leakage power by chip designer, and the modified circuit can be applied without any modification in design flow.

차동기어장치를 적용한 입력축 연결방식 무단변속기의 동력흐름 및 효율해석에 관한 연구 (Power Flow and Efficiency of Input Coupled type CVT combined Differential Gear Unit)

  • 김연수;최상훈
    • 한국정밀공학회지
    • /
    • 제17권11호
    • /
    • pp.141-150
    • /
    • 2000
  • Continuously variable transmission(CVT) combined differential gear unit has many advantages, which are the decrease of CVT size, the increase of overall efficiency, the extension of speed ratio range, and the generation of geared neutral. It is known that such CVT can be classified into the input coupled type and the output coupled type according to the coupling location of continuously variable unit(CVU). In this paper, six different configurations of input coupled type CVT combined V-belt CVU and 2K-H I type differential gear unit are proposed. Some useful theoretical formula related to speed ratio, power flow and efficiency are derived and analyzed. The propriety of derived formula and theoretical analysis are proven by various experiments.

  • PDF

2 상 유동 및 물질전달 특성에 미치는 오리피스 노즐형상과 소요동력의 영향 (Effect of Orifice Nozzle Design and Input Power on Two-Phase Flow and Mass Transfer Characteristics)

  • 양희천
    • 대한기계학회논문집B
    • /
    • 제40권4호
    • /
    • pp.237-243
    • /
    • 2016
  • 호기성 수처리 과정의 폭기에 소요되는 에너지의 이용효율을 높이기 위해서는 물질전달 특성뿐만 아니라 소요동력에 대한 연구가 필요하다. 본 논문은 수직 2 상 유동 및 물질전달 특성에 미치는 오리피스 노즐형상과 소요동력의 영향에 대한 실험적 연구를 목적으로 한다. 측정 변수들을 이용하여 유량비, 소요동력, 물질전달 계수 그리고 물질전달 효율을 산출하였다. 소요동력이 커지면 물질전달 계수는 증가하는 반면에 유량비와 물질전달 효율은 감소하였다. 무차원 면적비가 작은 오리피스 노즐의 유량비, 물질전달 계수 및 효율이 높게 나타났다. 물질전달 특성에 미치는 유량비, 소요동력 그리고 프라우드 수의 영향을 평가하기 위한 실험식을 제시하였다.

Reliability Evaluation of RF Power Amplifier for Wireless Transmitter

  • Choi, Jin-Ho
    • Journal of information and communication convergence engineering
    • /
    • 제6권2호
    • /
    • pp.154-157
    • /
    • 2008
  • A class-E RF(Radio Frequency) power amplifier for wireless application is designed using standard CMOS technology. To drive the class-E power amplifier, a class-F RF power amplifier is used and the reliability characteristics are studied with a class-E load network. The reliability characteristic is improved when a finite-DC feed inductor is used instead of an RF choke with the load. After one year of operating, when the load is an RF choke the output current and voltage of the power amplifier decrease about 17% compared to initial values. But when the load is a finite DC-feed inductor the output current and voltage decrease 9.7%. The S-parameter such as input reflection coefficient(S11) and the forward transmission scattering parameter(S21) is simulated with the stress time. In a finite DC-feed inductor the characteristics of S-parameter are changed slightly compared to an RF-choke inductor. From the simulation results, the class-E power amplifier with a finite DC-feed inductor shows superior reliability characteristics compared to power amplifier using an RF choke.