• Title/Summary/Keyword: Input/output Control

Search Result 2,504, Processing Time 0.035 seconds

Development of Auto-tuning Temperature Controller with Multi-channel (다중채널을 갖는 오토튜닝 온도 제어기 개발)

  • Lee, Kap Rai
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.4
    • /
    • pp.419-427
    • /
    • 2018
  • This paper designs and develops auto-tuning temperature controller with multi-channel, which controller with multi-channel could control a number of control system simultaneously. This controller has multi-channel input and output. And a number of control algorithms run in this controller simultaneously and independently. Firstly we present design method of controller with multi-channel. Secondly we design electrical circuit of sensor input, controller output and power control for temperature control board. And finally we design data protocol for serial communication to monitor control state and present verification of temperature controller with muiti-channel through field experiment.

EDFA Gain Stabilization via Disturbance Observer Techniques

  • Im, Yoon-Tae;Seo, Kwang-Bok;Song, Seong-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2143-2146
    • /
    • 2003
  • We propose, for the first time to our knowledge, a novel gain-clamping method for EDFA in WDM Add/Drop networks by introducing a disturbance observer technique. The proposed gain-clamping control input consists of the nominal gain-clamping control such as PI(Proportional and Integral) control and the additional control input for the compensation of the effects caused by channel add/drops. The additional control input is designed using the wellknown disturbance observer technique and can be implemented very easily with general electric elements. We proved the superiority of the new technique over the previous methods by showing simulation result of minimized dips and spikes that appear in power profile of EDFA output.

  • PDF

Data fusion based improved HOSM observer for smart structure control

  • Arunshankar, J.
    • Smart Structures and Systems
    • /
    • v.24 no.2
    • /
    • pp.257-266
    • /
    • 2019
  • The benefit of data fusion in improving the performance of Higher Order Sliding Mode (HOSM) observer is brought out in this paper. This improvement in the performance of HOSM observer, resulted in the improvement of active vibration control of a piezo actuated structure, when controlled by a Discrete Sliding Mode Controller (DSMC). The structure is embedded with two piezo sensors for measuring the first two vibrating modes. The fused output of sensors is applied to the HOSM observer for generating state estimates, these states generated are applied to the DSMC, designed for the fourth order linear time invariant model of the structure. In the simulation study, the structure is excited at the first and second mode resonance. It is found that better vibration suppression is obtained, when the states generated by the fused output of sensors is applied as controller input, than the vibration suppression obtained by applying the states generated by using individual sensor output. The closed loop performance of DSMC obtained with HOSM observer is compared with the closed loop performance obtained with the conventional observer. Results obtained shows that better vibration suppression is obtained when the states generated by HOSM observer is applied as controller input.

Analysis, Design and Implementation of a Soft Switching DC/DC Converter

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.20-30
    • /
    • 2013
  • This paper presents a soft switching DC/DC converter for high voltage application. The interleaved pulse-width modulation (PWM) scheme is used to reduce the ripple current at the output capacitor and the size of output inductors. Two converter cells are connected in series at the high voltage side to reduce the voltage stresses of the active switches. Thus, the voltage stress of each switch is clamped at one half of the input voltage. On the other hand, the output sides of two converter cells are connected in parallel to achieve the load current sharing and reduce the current stress of output inductors. In each converter cell, a half-bridge converter with the asymmetrical PWM scheme is adopted to control power switches and to regulate the output voltage at a desired voltage level. Based on the resonant behavior by the output capacitance of power switches and the transformer leakage inductance, active switches can be turned on at zero voltage switching (ZVS) during the transition interval. Thus, the switching losses of power MOSFETs are reduced. The current doubler rectifier is used at the secondary side to partially cancel ripple current. Therefore, the root-mean-square (rms) current at output capacitor is reduced. The proposed converter can be applied for high input voltage applications such as a three-phase 380V utility system. Finally, experiments based on a laboratory prototype with 960W (24V/40A) rated power are provided to demonstrate the performance of proposed converter.

A Prototype Development of Personal Low-frequency Stimulator with Characteristic Analysis (개인용 저주파 자극기의 특성분석 및 Prototype개발)

  • Lee, Gi-Song;Lee, Dong-Ha;Yu, Jae-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.349-352
    • /
    • 2003
  • A personal low-frequency stimulator is a portable device to relax muscle pains of a person. The stimulator generates combined low-frequency pulses to be applied to pads attached to painful muscles. This paper reports a development of such device with its characteristic analyses. The major components of our stimulator are MCU, high-voltage generating circuit part, high-voltage switching circuit part, input switch part and display unit. High-voltage generating circuit is designed by using a boost converter circuit and allows user control of the output voltage. High-voltage switching circuit, controlled by MCU, generates output voltage to be applied to pads. Input switch part is composed of power supply, intensity selection, mode selection and memory. Display unit adopts a text LCD module to display modes, Intensity, output frequency and user set-up time. Our designed safety circuit, to protect human body from possible electric shock, slowly increases the output voltage to the selected output intensity. It continuously checks the output pulse shape and disable the output when dangerous pulses are detected. This paper also shows some experimental results.

  • PDF

A study on the haromnic attenuation of the BF Converter (BF 컨버터의 고조파 감쇠에 관한 연구)

  • 최태섭;안인수;임승하;사공석진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.8-15
    • /
    • 2000
  • In this paper, we realize the active PFC(Power Factor Correction) system of BF(Boost Forward) converter with PWM-PFM(Pulse Width Modulation-Pulse Frequency Modulation) control technique to control DC output voltage, to remove the noise like harmonics at output voltage, and to control the input current with sinusoidal wave synchronized by the source voltage.To achieve the desired load voltage and improved PFC, we first implement current shaping control at the inverting stage and make the converted output DC voltage with forward converter. After making the ratio of output voltage to current as 50V/1A and the duty ratio greater than 0.5. When input voltage is 30V and boost inductance is 1.1mH. we control the voltage changing rate according to the variation of load resistance using a PWM-PFM control technique. And finally we prove experimentally, we attenuated its harmonics and improved PF up to 0.96 using the current shaping technique.

  • PDF

Ammonia flow control for NOx reduction in SCR system of refuse incineration plant (소각로의 NOx 제어용 SCR 시스템의 암모니아 공급량제어)

  • Kim, In-Gyu;Yeo, Tae-Gyeong;Kim, Hwan-Seong;Kim, Sang-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.451-457
    • /
    • 1998
  • This paper describes a modelling method for SCR(selective catalystic reduction) system in refuse incineration plant. We consider the SCR system as a single input and single output system. For modelling the SCR system, an auto regressive exogeneous(ARX) modelling method is used. In this case, we should design the white noise input for modelling and put it on the system as an input$(NH_3)$, and take an outlet NOx as an output. From these two relations, we design the ARX model with 45 second delay time and transform to a discrete system with sampling time of 0.5 second. Using the obtained SCR model, we verify that the outlet NOx is deeply related with stoker`s moving in boiler of refuse incineration plant.

A Study on Self-tunning of PID Controller using Neural Network Theory (신경망이론을 이용한 PID제어기의 자기동조에 관한 연구)

  • Jun, Kee-Young;Hahm, Nyoun-Kun;Sung, Nark-Kuy;Lee, Seung-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2610-2612
    • /
    • 1999
  • In controlling vector of induction motor, PID controller is required much time as the expert should control manually a gain of controller according to plant or a change of circumstances. Accordingly, this paper has gotten a gain of PID controller used neural network by self-funning method in order to settle above problem. The neural network can describe an input/output features in spite of non-linear system which is hard to get mathematical model by controlling the strength of connection by learning. It has a strong character against a distortion and noise of input information, and is suitable modeling of diver-variable system which is composed of several input/output. This paper has represented the self-tunning method for gain of PID controller used neural network when using PID controller to control speed of induction motor, and has checked strong characters against distortion and noise of input information through simulation.

  • PDF

Standby Power Reduction Technique due to the Minimization of voltage difference between input and output in AC 60Hz (대기전력 최소화를 위한 교류전압 입력에 따른 저전압 구동회로 설계)

  • Seo, Kil-Soo;Kim, Ki-Hyun;Kim, Hyung-Woo;Lee, Kyung-Ho;Kim, Jong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1018-1019
    • /
    • 2015
  • Recently, standby power reduction techniques of AC/DC adaptor were developed, consuming power almost arrived to 300mW level. The standby power losses are composed of the input filter loss 11.8mW, the control IC for AC/DC adaptor 18mW, the switching loss 9.53mW and the feedback loss 123mW. And there are the standby power reduction techniques. In this paper, in order to reduce the standby power of SMPS more, the loss due to a voltage difference between input and output is reduced by the control circuit which is composed of the low voltage driving circuit and voltage regulator. The low voltage driving circuit operates on the low voltage of input and off the high voltage. The low voltage driving IC was produced by the $1.0{\mu}m$, high voltage DMOS process.

  • PDF

A Variable Structure Point-to-Point Regulation Controller for Uncertain General Linear Systems (불확실 선형 시스템을 위한 적분 가변구조 지점에서 지점으로 레귤레이션 제어기)

  • Lee, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.519-525
    • /
    • 2014
  • In this paper, an alternative variable structure controller is designed for the point-to-point regulation control of uncertain general linear plants so that the output of plants can be controlled from an arbitrarily given initial point to an arbitrarily given reference point in the state space. By using the error between the steady state value of the output and an arbitrarily given reference point and those integral, a transformed integral sliding surface is defined, in advance, as the surface from an initial state to an arbitrarily given reference point without the reaching phase problems. A corresponding control input is suggested to satisfy the existence condition of the sliding mode on the preselected transformed integral sliding surface against matched uncertainties and disturbances. Therefore, the output controlled by the proposed controller is completely robust and identical to that of the preselected transformed integral sliding surface. Through an example, the effectiveness of the suggested controller is verified.