• Title/Summary/Keyword: Input/output Control

검색결과 2,504건 처리시간 0.029초

A New Control Strategy for Input Voltage Sharing in Input Series Output Independent Modular DC-DC Converters

  • Yang, Wei;Zhang, Zhijie;Yang, Shiyan
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.632-640
    • /
    • 2017
  • Input series output independent (ISOI) dc-dc converter systems are suitable for high voltage input and multiple output applications with low voltage rating switches. This paper proposes a novel control strategy consisting of one output voltage regulating (OVR) control loop and n-1 (n is the number of modules in the ISOI system) input voltage sharing (IVS) control loops. An ISOI system with the proposed control strategy can be applied to applications where the output loads of each module are the same. Under these conditions, IVS can be achieved and output voltages copying can be realized in an ISOI system. In this control strategy there is only one controller for each module and the design process of the control loops is simple. Since no central controller is needed in the system, modularity of the system is improved. The operation principle of the new control strategy is introduced and the control effect is simulated. Then the output power and voltage characteristics of an ISOI system under this new control strategy are analyzed. The stability of the proposed control strategy is explored base on a Hurwitz criterion, and the design guide line of the control strategy is given. A two module ISOI system prototype is fabricated and tested in the laboratory. Experimental results verify the effectiveness of the proposed control strategy.

A Novel Control Strategy for Input-Parallel-Output-Series Inverter System

  • Song, Chun-Wei;Zhao, Rong-Xiang;Lin, Wang-Qing;Zeng, Zheng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.85-90
    • /
    • 2012
  • This paper presents a topology structure and control method for an input-parallel-output-series(IPOS) inverter system which is suitable for high input current, high output voltage, and high power applications. In order to ensure the normal operation of the IPOS inverter system, the control method should achieve input current sharing(ICS) and output voltage sharing(OVS) among constituent modules. Through the analysis in this paper, ICS is automatically achieved as long as OVS is controlled. The IPOS inverter system is controlled by a three-loop control system which is composed of an outer common-output voltage loop, inner current loops and voltage sharing loops. Simulation results show that this control strategy can achieve low total harmonic distortion(THD) in the system output voltage, fast dynamic response, and good output voltage sharing performance.

입/출력 Automata의 제어에 관한 연구 (A Study on the Control of Input/output Automata)

  • 문홍주;권욱현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.313-315
    • /
    • 1993
  • This paper presents the control of input/output automata. The input/output automata provides an appropriate model for discrete event systems consisting of concurrently-operating components. Ramadge and Wonham's supervisor controller can be transformed into the controllter of input/output automata. Using input/output automata, the modelling can be more realistic and concurrent discrete event systems can be controlled easily.

  • PDF

고속전철 보조전원 장치용 입력직렬-출력병렬 컨버터의 제어 및 설계 (Control and Design of Input Series-Output Parallel Connected Converter for High Speed Train Power System)

  • 김정원;유정식;조보형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.282-290
    • /
    • 2000
  • In this paper, the charge control with the input voltage feedback is proposed for the input series-output series-output parallel connected converter configuration for the high speed train power system application. This control scheme accomplishes the output current sharing for the output-parallel connected modules as well as the input voltage sharing for the input series connected modules for all operating conditions including the transients. It also offers the robustness for the input voltage sharing control according to the component value mismatches among the modules. And this configuration enables the usage of MOSFET for a high voltage system allowing a higher switching frequency for lighter system weight and smaller size. The performance of the proposed scheme is verified through the experimental results.

  • PDF

Inversion-Based Robust Output Tracking of Differentially Flat Nonlinear Systems

  • Joo, Jin-Man;Park, in-Bae;Park, Yoon-Ho
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제3권1호
    • /
    • pp.21-26
    • /
    • 2001
  • In this study, we propose a two degree of freedom robust output tracking control method for a class of nonlinear system. We consider hyperbolically nonminimum phase single-input single-output uncertain nonlinear systems. We also consider the case that the nominal input-state equation is differentially flat. Nominal stable state trajectory is obtained in the flat output space via the flat output. Nominal feedforward control input is also computed from the nominal state trajectory. Due to the nature of the method, the generated flat output trajectory and control input are noncausal. Robust feedback control is designed to stabilize the systems around the nominal trajectory. A numerical example is given is given to demonstrate that robust tracking is achieved.

  • PDF

수정된 출력을 이용한 다기 전력 계통의 분살 입출력 되먹임 선형화 제어 (Decentralized Input-Output Feedback Linearizing Control for a Multi-Machine Power System using Output Modification)

  • 지황;윤태웅;김석균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.291-294
    • /
    • 2006
  • This paper presents a decentralized input-output feedback linearizing controller for a multi-machine power system. Firstly, the controller is designed using input-output feedback linearization for modified outputs. Then we present a guideline for selecting gains of the controller and parameters in the modified outputs. Simulations illustrate the effectiveness of the proposed control scheme and the selection guideline.

  • PDF

입력 직류 전압과 Z-네트워크 커패시터 전압 검출에 의한 Z-소스 인버터의 출력 전압 제어 (Output Voltage Control of Z-Source Inverter by the Detection of the Input DC Voltage and Z-Network Capacitor Voltage)

  • 김세진;정영국;임영철;최준호
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1515-1522
    • /
    • 2011
  • This paper proposes the algorithm for the output AC voltage control of Z-source inverter by the detection of the input DC voltage and Z-network capacitor voltage. The actual modulation index of the proposed method is detected by the capacitor voltage in Z-network and input DC voltage of three-phase Z-source inverter. Control modulation index for the output voltage control is calculated by the detected actual modulation index and reference modulation index. And, calculated control modulation index is applied to the modified space vector modulation (SVM) for control the output voltage of Z-source inverter. To verify the validity of the proposed method, PSIM simulation was achieved and a DSP controlled 1[kW] three-phase Z-source inverter was producted. The simulation and experiment were performed under the condition that the load was changed in case of the constant input DC voltage and the input DC voltage was changed in case of the load was constant. As a result, we could know that the output phase voltage of Z-source inverter followed to the reference voltage 70[VRMS] despite the load or the input DC voltage were suddenly changed.

Temperature Control of Ultrasupercritical Once-through Boiler-turbine System Using Multi-input Multi-output Dynamic Matrix Control

  • Moon, Un-Chul;Kim, Woo-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.423-430
    • /
    • 2011
  • Multi-input multi-output (MIMO) dynamic matrix control (DMC) technique is applied to control steam temperatures in a large-scale ultrasupercritical once-through boiler-turbine system. Specifically, four output variables (i.e., outlet temperatures of platen superheater, finish superheater, primary reheater, and finish reheater) are controlled using four input variables (i.e., two spray valves, bypass valve, and damper). The step-response matrix for the MIMO DMC is constructed using the four input and the four output variables. Online optimization is performed for the MIMO DMC using the model predictive control technique. The MIMO DMC controller is implemented in a full-scope power plant simulator with satisfactory performance.

적분 슬라이딩 모드 제어기를 이용한 출력 궤환 안정화 (Output Feedback Stabilization using Integral Sliding Mode Control)

  • 오승록
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권3호
    • /
    • pp.142-147
    • /
    • 2003
  • We consider a single-input-single-output nonlinear system which can be represented in a normal form. The nonlinear system has a modeling uncertainties including the input coefficient uncertainty. A high-gain observer is used to estimate the states variables to reject a modeling uncertainty. A globally bounded output feedback integral sliding mode control is proposed to stabilize the closed loop system. The proposed integral sliding mode control can asymptotically stabilize the closed loop system in the presence of input coefficient uncertainty.

The Cascade PID Type Fuzzy Control Method

  • Lee, Jung-Hoon;Ki whan Eom;Lee, Yong-Gu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.93.3-93
    • /
    • 2001
  • We propose the cascade PID type fuzzy control method for a good performance such as robustness. The one of proposed method, the first stage have two input variables of an error and a derivative error, and one output variable, and the next stage have two input variables of the output of first stage and an integral error, and one output variable, have two stages. The other, the first stage has one input of an error, and one output variable, and the second stage have two input of the output of first stage and a derivative error, and one output variable, and the third stage have two input of the output of the second stage and an integer error, and one output variable ...

  • PDF