• Title/Summary/Keyword: Input/Output Analysis

Search Result 2,374, Processing Time 0.027 seconds

A Note on Methodologies Used in I-O Forecasting Model

  • Kim, Dai-Young
    • Journal of the Korean Statistical Society
    • /
    • v.5 no.1
    • /
    • pp.35-48
    • /
    • 1976
  • Since the solution vector for input-output forecasting models is not directly obtainable, several iterative procedures have been proposed and utilized. As is often the case in numerical analysis, the question of the consistency between the original system and the converged system of the proposed iteration has been ignored, and no one has tried to express the converged solution explicitly. This paper examines this question and points out the inconsistencies between various well-known iterative procedures used to solve input-output models and the original input-output system.

  • PDF

Resonance characteristics and electrical properties of PZT-piezoelectric transformer (PZT계 압전변압기의 공진특성과 전기적 성질)

  • 박순태;정수태;이종헌
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.27-34
    • /
    • 1995
  • The analysis of nonlinear equivalent circuit and the resonance characteristics of input current and output voltage were simulated, and their electrical properties are discussed in the transverse-type piezoelectric ceramic transformer. The nonlinear resonance characteristics of input current and output voltage showed by the thermal effect due to a higher driving current, the nonlinearity increased greatly as driving current increased. When load resistor was 100[M.ohm.], the nonlinear coefficient was -1.3. The nonlinear resonance curve of input current and output voltage for a variation of input voltage and load resistor agreed with the discussed theory. The output voltage increased nearly proportioned to input voltage when load resistors were below 50[M.ohm.], the voltage step-up ratio decreased when a load resistor was 100[M.ohm.] and their maximum value was 950.

  • PDF

On Sensitivity of Design Variables for Automation of Iterative Design Procedures (반복 설계 과정의 자동화를 위한 설계 변수 영향관계에 관한 연구)

  • Ryu, Gap-Sang;Sin, Jung-Ho
    • 한국기계연구소 소보
    • /
    • s.18
    • /
    • pp.125-129
    • /
    • 1988
  • This paper proposes a sensitivity technique for analysis of the relationships between input variables (known values) and output variables(unknown values), These design variables are constrained by design equations. Thus, the output variables can be calculated by solving the equations with eliminating the input variables from the equations because the input variables become constants. If the output variables are not satisfied, the values of the input variables must be adjusted by increasing or decreasing the values and then the problem must be solved again. This is called as the iterative design procedure. The sensitivity technique, presented in this paper, gives the sensitivity on the changes of the values of the output variables to the input variables.

  • PDF

Self-tuning control with bounded input constraints

  • Jee, Gyu-In
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1655-1658
    • /
    • 1991
  • This paper considers the design and analysis of one-step ahead optimal and adaptive controllers, under the restriction that a known constraint on the input amplitude is imposed. It is assumed that the discrete-time single-input, single-output system to be controlled is linear, except for inequality constraints on the input. The objective function to be minimized is an one-step quadratic function, where polynomial weights on the input and output are included. Both the known parameter and unknown parameter (indirect adaptive controller) cases are examined.

  • PDF

A development of input and output interfaces for fuzzy hierarchical analysis

  • Kwack, H.Y.;Lee, S.D.;Son, I.M.
    • Proceedings of the ESK Conference
    • /
    • 1996.10a
    • /
    • pp.181-184
    • /
    • 1996
  • Fuzzy hierarchical analysis(FHA) has the usefulness to allow decision maker's ambiguities when comparing two alternatives. But, for easiuly appling it to a decision problem, the handling its many data and for decision makers much not knowing fuzzy theory are the obstacles to must be overcomed even if the results of final fuzzy weights can be computed by a personal computer. This paper decribes that FHA is revised, and input/output interfaces are developed to collect input data easily and interprete the fuzzy resultlts. Finally, a fuzzy decision process is suggested with them.

  • PDF

Study on assessment of the environmental impacts for track system by Input-Output Analysis (산업연관분석법에 의한 궤도시스템의 환경부하 평가)

  • Kim, Yong-Ki;Lee, Cheul-Kyu;Jeon, Yong-Sam;Jo, Hyun-Jung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.73-76
    • /
    • 2009
  • LCA is nowadays getting popular as a tool to assess the environmental impacts. We can assess the environmental impacts of products and also compare the environmental performance between products with LCA. Furthermore, the LCA results can be used for designing eco-friendly products. But LCA needs an enormous amount of data collection, calculations of energy and material balance. which required to spend pretty much time and cost. However, If we use Input-Output Analysis, There is a lot of advantages that we can save time and cost to calculate and also analyze energy-material balance more comprehensively. Therefore, we implemented the fundamental research of the environmental impact assessment on railway system using life cycle inventory analysis and Input-Output Analysis method.

  • PDF

Double-Input DC-DC Converter for Applications with Wide-Input-Voltage-Ranges

  • Hu, Renjun;Zeng, Jun;Liu, Junfeng;Yang, Jinming
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1619-1626
    • /
    • 2018
  • The output power of most facilities for renewable energy generation is unstable due to external environmental conditions. In distributed power systems with two or more sources, a stable output can be achieved with the complementary power supply among the different input sources. In this paper, a double-input DC-DC converter with a wide-input-voltage-range is proposed for renewable energy generation. This converter has the following advantages: the circuit is simple, and the input voltage range is wide and the fault tolerance is excellent. The operation modes and the steady-state analysis are examined. Finally, experimental results are illustrated to verify the correctness of the analysis and the feasibility of the proposed converter.

Analysis of Technology Convergence Structure Using technology Input-output Analysis: Case of Convergence R&D Development Project for Small and Medium Businesses (기술연관분석을 활용한 기술융합구조 분석: 중소기업 융·복합기술개발사업 사례)

  • Lee, Kwang-Min;Kim, Da-Woon;Hong, Jae-Bum
    • Journal of Technology Innovation
    • /
    • v.22 no.3
    • /
    • pp.1-35
    • /
    • 2014
  • This study analyzed convergence status among input technologies used in technology development with Technology I-O analysis. It was another version of industry input-output analysis which is used in technology planning. This case is an analysis of association between technology an product. The subjects of analysis were 401 tasks that applied to '2012 Convergence Technology Development Project for Small and Medium Businesses' promoted by Korea Technology & Information Promotion Agency for Small and Medium Enterprises. The process of analysis is as followed. First step, we made a matrix table as an input of technology input-output analysis. Input was defined by technology and output was defined by the product. Input technology was defined in a 3-digit code under National Science Technology Classification and output products were defined in a 5-digit under National Standard Industry Code. Second, the Spillover ratio among technologies were calculated and was used to make a picture of technology linkage. As a result of analysis, technology spillover of embedded S/W was the highest in IT convergence, mold product in ET convergence, and functional cosmetics development technology in BT convergence. In general, IT convergence had many element technologies with high technology spillover, and ET had a small number of element technologies with high technology spillover. Therefore, investment effect of element technology is expected to be large if investment on element technologies with high technology spillover is important for vitalizing convergence.

Environmental Impact Assessment at a School Building using Input-output Table - Focused on Elementary School in Gyeonggi-do - (산업연관분석법을 이용한 학교 건물에서의 환경영향평가 - 경기지역의 초등학교를 대상으로 -)

  • Choi, Doo-Sung;Jeon, Hung-Chan;Cho, Kyun-Hyong
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: A lot of active researches have addressed the impact of a building on global environment, but most of the researches focus on a residential building and a large office building. Hereupon, this study assessed the impact on environment quantitatively through the analysis of input materials targeting a school building. Method:This study calculated embodied energy of input materials suggested in a construction statement on a school building using the input-output analysis. This study finally carried out environmental impact assessment by applying LCIA DB shown in the preceding researches to the calculated embodied energy. Result: The analysis result revealed that the environmental impact per unit area(/$m^2$) at a school building was $4.11E-02PE{\cdot}yr$, among which Construction was found to be $3.59E-02PE{\cdot}yr$, being analyzed to account for about 87% of the total environmental impact. Also, as a result of detailed environmental impact, the impact on global warming among the total environmental impact was analyzed to be high, accounting for about 76%.

Induced Production Analysis for Photovoltaic Power Generation Equipment in Korea using Input-Output Table 2009 (산업연관표 2009를 이용한 태양광발전설비산업의 생산유발효과분석)

  • Kim, Yoon-Kyung
    • New & Renewable Energy
    • /
    • v.8 no.1
    • /
    • pp.8-17
    • /
    • 2012
  • The Korean government pushed ahead various policies to disseminate photovoltaic (PV), wind power, small hydro, bio-fuel, etc. Renewable energy system (RES) budget of the Korean government increased from 118 billion won of 2003 to 876.6 billion won of 2010. The R&D budgetary supports for RES increased by 6.8 times in the period 2003-2010. It is necessary to confirm RES budget expenditure that renewable energy promotion policy makes good performance evaluated in quantity level. This paper made Input-Output Table 2009 contains photovoltaic power generation equipment industry as a dependent sector and analyzed induced production effect by demand of photovoltaic power generation equipment industry. From the empirical analysis result, additional demand in photovoltaic power generation equipment induced 1.932 times of induced production in Korea. Each of industry sector has positive induced production from the additional demand in photovoltaic power generation equipment. Renewable energy promotion in photovoltaic power generation is considered together with industry policy as the option to sustain economic growth.