• Title/Summary/Keyword: Inner power

Search Result 842, Processing Time 0.032 seconds

Grid-friendly Characteristics Analysis and Implementation of a Single-phase Voltage-controlled Inverter

  • Zhang, Shuaitao;Zhao, Jinbin;Chen, Yang;He, Chaojie
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1278-1287
    • /
    • 2017
  • Inverters are widely used in distributed power generation and other applications. However, their lack of inertia and variable impedance may cause system instability and power transfer inaccuracy. This paper proposes a control scheme for a single phase voltage-controlled inverter with some grid-friendly characteristics. The proposed control algorithm enables the inverter to function as a voltage source with an inner output impedance in both the islanded and grid-connected modes. Virtual inertia and rotor equations are embedded in the PLL part. Thus, the frequency stability can remain. The inner output impedance can be adjusted freely, which helps to accurately decouple and transmit the output active and reactive power. The proposed inverter operates like a traditional synchronous generator. Simulations and experiments are designed and carried out to verify the proposed control strategy.

An Analysis on Volumetric Displacement of Gerotor Pump/Motor Using Vane Length (회전날개 길이를 이용한 제로터 펌프/모터의 배제용적에 관한 연구)

  • Kim, S.D.;Kim, D.M.;Ham, Y.B.;Han, C.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.2
    • /
    • pp.8-16
    • /
    • 2011
  • It is hard and complicated to analytically derive the volumetric-displacement formula of a gerotor pump/motor. Analytical formulas for calculating the volumetric-displacement are derived in this work, which is relatively easy and based upon vane lengths. The vane lengths mean the distances from axis of inner rotor or outer rotor to contact points between inner and outer rotors. Two kinds of formula were studied for two different kinematic motions of rotors. The first one is the case that outer rotor is fixed in space and inner rotor is in mixed motion of planetary revolution and rotation with respect to the spinning axis. And the second is the case that both inner and outer rotors simultaneously rotate. The proposed formula is verified through comparison with volumetric-displacement obtained from numerical CAD calculation.

Design of PM Excited Transverse Flux Linear Motor of Inner Mover Type

  • Kang Do-Hyun;Ahn Jong-Bo;Kim Ji-Won;Chang Jung-Hwan;Jung Soo-Jin
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.137-141
    • /
    • 2005
  • A transverse flux, PM-exited linear motor (TFM-LM) with inner mover was designed and built. Its output power density is higher and its weight is lower than those of the conventional PM exited linear synchronous motors (PM LSM). To obtain the maximum thrust force under the given volume, the thrust force density with respect to the ratio of the slot width and the length of pole pitch is analyzed by the 3-dimension finite element method (FEM). Finally, calculated static thrust forces was compared with the experimental values. The calculated and measured performance of the transverse flux, PM-exited linear motor with inner mover revealed great potential for system improvements by reducing the mass of the linear motor. For examples, when this motor was applied to a ropeless elevator, it was possible to increase the power density by more than 400% over the conventional PM-LSM. The results of this study recommend this type of motor for the ropeless elevator or gearless direct linear driving system.

Breakdown and Destruction Characteristics of the CMOS IC by High Power Microwave (고출력 과도 전자파에 의한 CMOS IC의 오동작 및 파괴 특성)

  • Hong, Joo-Il;Hwang, Sun-Mook;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1282-1287
    • /
    • 2007
  • We investigated the damage of the CMOS IC which manufactured three different technologies by high power microwave. The tests separated the two methods in accordance with the types of the CMOS IC located inner waveguide. The only CMOS IC which was located inner waveguide was occurred breakdown below the max electric field (23.94kV/m) without destruction but the CMOS IC which was connected IC to line organically was located inner waveguide and it was occurred breakdown and destruction below the max electric field. Also destructed CMOS IC was removed their surface and a chip condition was analyzed by SEM. The SEM analysis of the damaged devices showed onchuipwire and bondwire destruction like melting due to thermal effect. The tested results are applied to the fundamental data which interprets the combination mechanism of the semiconductors from artificial electromagnetic wave environment and are applied to the data which understand electromagnetic wave effects of electronic equipments.

CONCEPTUAL DESIGN OF INNER-SPHERICAL CONTINUOUSLY VARIABLE TRANSMISSION FOR BICYCLE USAGE

  • SEONG S. H.;RYU J. H.;LEE H. W.;PARK N. G.
    • International Journal of Automotive Technology
    • /
    • v.6 no.5
    • /
    • pp.467-473
    • /
    • 2005
  • A continuously variable transmission (CVT) with an inner spherical traction drive was conceptually designed for bicycle usage. The range of the overall speed ratio is from 1.0 to 4.5. The rated power and pedal speed are 100 Watts and 6 rad/s, respectively. The peculiar packageability, high-level power efficiency and high torque capacity were considered in the design process. A compact CVT that can be installed within a $244\times125\times160mm^3$ space and is above 0.9 in efficiency for the rated values was numerically designed. The distribution of efficiency according to the input torque and input speed were calculated. Gradeability in the prescribed operation mode was simulated.

Mobile Target Speed Estimation in Urban Environments with Adaptive Power Control (도시환경에서 적응전력제어를 이용한 이동국 속도추정)

  • Lee, Hyeon-Cheol;Lee, Jong Tae;Ryu, Sang Burm;Kang, Eun Su
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.1
    • /
    • pp.46-50
    • /
    • 2016
  • The adaptive power control of Code Division Multiple Access (CDMA) systems for communications between User Equipments (UEs) with a link-budget based Signal-to-Interference Ratio (SIR) estimate which has distance information is applied to three inner loop power control algorithms. The speed estimation performances of these algorithms with their consecutive Transmit-Power-Control (TPC) ratios are compared to each other, and it is concluded that the speed can be estimated using the TPC ratio information of Consecutive TPC Ratio Step-size Closed Loop Power Control (CS-CLPC) and Fixed Step-size Power Control (FSPC).

Characterization of Antioxidant Activities from Chestnut Inner Skin Extracts

  • Jeong, Chang-Ho;Choi, Gwi-Nam;Kim, Ji-Hye;Kwak, Ji-Hyun;Choi, Sung-Gil;Heo, Ho-Jin
    • Food Science and Biotechnology
    • /
    • v.18 no.5
    • /
    • pp.1218-1223
    • /
    • 2009
  • Total phenolics and antioxidant activities of water and 80% methanol extract of chestnut inner skin were investigated. The antioxidant properties of both extracts of chestnut inner skin were evaluated using different antioxidant tests, including 1,1-diphenyl-2-picrylhydrazyl (DPPH), 2,2-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid) (ABTS) radical scavenging activities, reducing power, ferric reducing ability of plasma (FRAP), and inhibitory effects on ${\beta}$-carotene bleaching. The 80% methanol extract of inner skin exhibited the higher DPPH, ABTS radical scavenging activities, reducing power, and FRAP than water extract of inner skin and did also in a concentration-dependent manner. However, inhibitory effects on ${\beta}$-carotene bleaching of 80% methanol extract was similar to those of water extract, 35.09 and 39.07% at 1 mg/mL, respectively. The total phenolic contents of water and 80% methanol extract from chestnut inner skin were 5,801.42 and 9,735.56 mg/100 g, respectively. High performance liquid chromatography (HPLC) analysis showed that gallic acid was the predominant phenolic compound in water and 80% methanol extract from inner skin. These water and 80% methanol extracts of chestnut inner skin can be utilized as an effective and safe source of antioxidants.

The New Architecture of Low Power Inner Product Processor for Reconfigurable Neural Networks (재구성 가능한 뉴럴 네트워크 구현을 위한 새로운 저전력 내적연산 프로세서 구조)

  • 임국찬;이현수
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.5
    • /
    • pp.61-70
    • /
    • 2004
  • The operation mode of neural network is divided into learning and recognition process. Learning is updating process of weight until neural network archives target result from input pattern. Recognition is arithmetic process of input pattern and weight. Traditional inner product process is focused to improve processing speed and hardware complexity. There is no hardware architecture to distinguish between loaming and recognition mode of neural network. In this paper we propose the new architecture of low power inner product processor for reconfigurable neural network. The proposed architecture is similar with bit-serial inner product processor on learning mode. It have several advantages which are fast processing base on bit-level, suitability of hardware implementation and pipeline architecture to compute data. And proposed architecture minimizes active units and reduces consumption power on recognition mode. Result of simulation shows that active units is depend on bit representation of weight, but we can reduce active units about 50 precent.

Design and Realization of a Digital PV Simulator with a Push-Pull Forward Circuit

  • Zhang, Jike;Wang, Shengtie;Wang, Zhihe;Tian, Lixin
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.444-457
    • /
    • 2014
  • This paper presents the design and realization of a digital PV simulator with a Push-Pull Forward (PPF) circuit based on the principle of modular hardware and configurable software. A PPF circuit is chosen as the main circuit to restrain the magnetic biasing of the core for a DC-DC converter and to reduce the spike of the turn-off voltage across every switch. Control and I/O interface based on a personal computer (PC) and multifunction data acquisition card, can conveniently achieve the data acquisition and configuration of the control algorithm and interface due to the abundant software resources of computers. In addition, the control program developed in Matlab/Simulink can conveniently construct and adjust both the models and parameters. It can also run in real-time under the external mode of Simulink by loading the modules of the Real-Time Windows Target. The mathematic models of the Push-Pull Forward circuit and the digital PV simulator are established in this paper by the state-space averaging method. The pole-zero cancellation technique is employed and then its controller parameters are systematically designed based on the performance analysis of the root loci of the closed current loop with $k_i$ and $R_L$ as variables. A fuzzy PI controller based on the Takagi-Sugeno fuzzy model is applied to regulate the controller parameters self-adaptively according to the change of $R_L$ and the operating point of the PV simulator to match the controller parameters with $R_L$. The stationary and dynamic performances of the PV simulator are tested by experiments, and the experimental results show that the PV simulator has the merits of a wide effective working range, high steady-state accuracy and good dynamic performances.

The decision of the inner fault of 154kV Gas Insulated Transformer through analyzing ingredients of insulated gas. (절연가스 성분분석을 통한 154kV 가스절연변압기 내부결함 판정)

  • Mun, Byong-Seon;Tark, Eui-Gyun;Lee, Tae-Kyu;Park, Chan-Eui;Lee, Min-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.447-448
    • /
    • 2015
  • In order to looking for method of detecting inner fault of a 154kV GIT(Gas Insulated Transformer), it was considered that diagnosis partial discharge(PD) in UHF band and that analyze the ingredients of SF6 insulating gas. UHF PD diagnosis that is optimized to GIS was considered unsuitable through checking of inner part of a transformers which PD is detected excessively. The method analyzing the content of six kinds of gas(SOF2, SO2F2, etc)was decided through analysis of chemical degradation and combination process and discharge experiment. With the result applying this method to analyze the content of insulated gas of eighty five Gas Insulated Transformers.

  • PDF