• Title/Summary/Keyword: Inner Fin

Search Result 77, Processing Time 0.021 seconds

Performance Analysis of a Geometrically Asymmetric Trapezoidal Fin for an Enhanced Heat Exchanger (향상된 열교환기를 위한 기하학적 비대칭 사다리꼴 핀의 성능 해석)

  • Song, Nyeon-Joo;Kang, Hyung-Suk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.4
    • /
    • pp.24-31
    • /
    • 2011
  • Performance of the asymmetric trapezoidal fin with various upper lateral surface slopes is investigated by using the two-dimensional analytic method. For a fin base boundary condition, convection from the inner fluid to the inner wall, conduction from the inner wall to the fin base and conduction through the fin base are considered. Heat loss and fin efficiency are represented as a function of the fin base thickness, base height, inner fluid convection characteristic number, fin tip length and fin shape factor. One of the results shows that heat loss increases while fin efficiency decreases as the fin shape factor increases.

Forming Simulation and Experiment for Progressive Fabrication Process of Inner Fin in Heat Exchanger

  • Ji, Dong-Hyeok;Jung, Dae-Han;Jin, Chul-Kyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.4
    • /
    • pp.405-413
    • /
    • 2019
  • In this study, a progressive process was performed to fabricate the inner fin of a high-efficiency heat exchanger. A forming simulation was also carried out on the concavo-convex of the inner fin, forming a simulation based on elastic-plastic finite element method. The forming analysis where the speed of the press descended and ascended was set to five seconds showed that the effective stress was at a maximum of about 69 MPa in the curved portion where the bending occurred. Therefore, the die was designed based on the simulation results, and the inner fin die was installed on the 400-ton capacity press. After that, the inner fin fabrication experiment was conducted under the same condition as the simulation. Crack was not found from the curved portion of the concavo-convex of the inner fin. The profile of the concavo-convex of the prepared inner fin measured 6.7~6.8 mm in depth, 2.65~2.7 mm in width, and 0.3 mm in thickness.

Optimization of an Annular Fin with a Pipe of Variable Inner Radius for Fixed Fin Volume (고정된 휜 체적에 기준한 원관 내부반경이 변하는 환형 휜의 최적화)

  • Kang, Hyung-Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.229-235
    • /
    • 2010
  • Optimum values of fin performance and dimensions for an annular fin with a rectangular profile and a pipe with variable inner radius are determined by using a variable separation method. The range of ambient convection characteristic number that results in optimum heat loss is listed. The optimum heat loss, corresponding optimum fin effectiveness, fin length, and fin height are presented as a function of the inner radius of the pipe, inner fluid convection characteristic number, fin volume, and ambient convection characteristic number. One of the results shows that the optimum heat loss, fin effectiveness and fin length increase linearly with the inner radius of the pipe when both the fin volume and fin-base radius are fixed.

Effects of Fin Configuration on the Evaporator Performance (휜 형상에 따른 증발기의 전열 성능)

  • Lee, Jin Ho;Kwon, O Kap
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.1
    • /
    • pp.27-36
    • /
    • 1990
  • An experimental investigation was made to study the performance characteristics of evaporator having different fin configurations and tube inner grooves. Three different types of fin such as super slitted fin, slitted fin, plain fin, and two types of tube such as inner grooved tube, and bare tube, are tested varying the air velocity, evaporation temperature and superheat of refrigerant. Results show that in the range of air side Reynolds number $3{\times}10^3\;-\;1.5{\times}10^4$ evaporator with super slitted fin and inner grooved tube shows best performance. It is 80% higher in overall heat transfer coefficient and 2.6 times higher in pressure loss compared to that with plain fin inner grooved tube. Friction factor is found to be almost independent of evaporating temperature and degree of superheat, while Colburn j factor varies with evaporating temperature.

  • PDF

Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins (2개의 수직휜이 부착된 내관으로부터 환상공간내의 자연대류 열전달)

  • 정태현;정한식;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.654-660
    • /
    • 1991
  • Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins has been studied for the effects of dimensionless fin length and Rayleigh number. The maximum local Nusselt number of inner tube was obtained at .theta. = 145.deg. and that of outer cylinder at .theta. = 0.deg. for the case of $l_{F}$=0.3 Local Nusselt number distributions for the lower fins show higher values than that of the upper fins. The mean Nusselt number of inner tube was increased with the values of dimensionless fin length. The mean Nusselt number can be represented in an exponential function of Grashof number at various fin lengths. As compared with experimental and numerical results, isotherms and local Nusselt number show good agreement.t.

Analysis of Temperature Distribution and Heat Loss for an Asymmetric Trapezoidal Fin (비대칭 사다리꼴 핀의 온도분포와 열손실 해석)

  • Kang, Hyung-Suk;Song, Nyeon-Joo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.377-383
    • /
    • 2012
  • The temperature distribution of an asymmetric trapezoidal fin with various upper lateral surface slopes is investigated by using the two-dimensional analytic method. For this asymmetric fin, convection from the inner fluid to the inner wall, conduction from the inner wall to the fin base and conduction through the fin base are considered simultaneously. The temperature profile with the variation of dimensionless fin length and height coordinates is shown. Also, the temperature variation at the bottom tip of the fin is presented as a function of the fin shape factor. Heat losses through the fin base and from each side are compared for variations in fin length. One of the results shows that temperature at the fin bottom tip decreases linearly as the fin shape factor increases.

A Study on the Entropy Generation of Single Fin-Tube Heat Exchanger (단일 핀-관 열교환기에서 엔트로피 생성에 관한 연구)

  • Pak, Hi-Yong;Lee, Kwan-Soo;Kim, Byoung-Kue
    • Solar Energy
    • /
    • v.10 no.1
    • /
    • pp.14-21
    • /
    • 1990
  • The entropy generation rate in a fin-tube heat exchanger is investigated as a basis for thermodynamic optimization associated with single fin-tube heat exchanger. The entropy generation (irreversibility)analysis is used to find the optimum design factor and investigate total entropy generation, optimum dimensions of fin length, tube inner and outer diameters, and fin spacing on the variation of design factors. The results of this study are as follows: As the outer diameter increases, optimum !in spacing and fin length increase but the entropy generation and optimum inner diameter decrease; As fin thickness increases, the entropy generation of system and optimum fin spacing increase; As fin length increases, entropy generation and optimum outer diameter increase.

  • PDF

Characteristic of Heat and Mass Transfer on Inner Ribbed Notched Fin Tube Absorber (내면가공 핀튜브 흡수기의 열 및 물질전달특성)

  • 설원실;권오경;문춘근;정용옥;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.478-485
    • /
    • 2000
  • An experimental study of the absorption process of water vapor into lithium bromide solution was performed. For the purpose of development of high performance absorption chiller-heater utilizing Lithium Bromide solution as working fluid, the absorber is the most effective to improve the performance of an absorber because it requires the largest heat transfer area in an absorption chiller-heater system. This paper introduces bare tube and inner ribbed notched fin tube for the absorber of absorption chiller-heaters. Inner ribbed notched fin tube has about 10∼20% higher heat and mass transfer performance than bare tube conventionally used in absorbers and the it is expected to perform high heat and mass transfer. This paper will provide important information on the selection of absorber tubes in commercial absorption chill-heaters.

  • PDF

Analysis of a Convective, Radiating Rectangular Fin (대류, 복사 사각 핀의 해석)

  • Kang, Hyung-Suk;Kim, Jong-Ug
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.29-34
    • /
    • 2006
  • A convective, radiating rectangular fin is analysed by using the one dimensional analytic method. Instead of constant fin base temperature, heat conduction from the inner wall to the fin base is considered as the fin base boundary condition. Radiation heat transfer is approximately linearized. For different fin tip length, temperature profile along the normalized fin position is shown. The fin tip length for 98% of the maximum heat loss with the variations of fin base length and radiation characteristic number is listed. The maximum heat loss is presented as a function of the fin base length, radiation characteristic number and Biot number.

  • PDF

Optimization of an Asymmetric Trapezoidal Fin Based on the Fixed Fin Base Height (고정된 핀 바닥 높이에 기준한 비대칭 사다리꼴 핀의 최적화)

  • Song, Nyeon-Joo;Kang, Hyung-Suk
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.1
    • /
    • pp.45-54
    • /
    • 2012
  • Optimization of the asymmetric trapezoidal fin with various upper lateral surface slope is made using a two-dimensional analytic method. For the fixed fin base height, the optimum heat loss, fin length and effectiveness are represented as inner fluid convection characteristic number, fin base thickness, fin base height, fin shape factor and ambient convection characteristic number. For this optimum procedure, the optimum heat loss is defined as 95% of the maximum heat loss from the fin. One of the results shows that optimum heat loss and effectiveness seems independent of the fin shape factor while optimum fin length decreases almost linearly as the fin shape factor increases.