• 제목/요약/키워드: Injection level

검색결과 1,591건 처리시간 0.027초

가스사출성형을 이용한 휴대용 화장품 보관함의 일체화 성형 연구 (A Study on the Unified Molding of a Portable Cosmetic Chest Using Gas-Assisted Injection Molding)

  • 이호상;류연선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.772-777
    • /
    • 2001
  • The gas-assisted injection molding process is often perceived to be unpredictable, because of the extreme sensitivity of the gas. Since a slight change in design or process parameters can significantly change the resulting gas penetration, few designers and molders have the level of experience with the new gas-assisted injection molding process required for the development of new parts. This paper is concerned with the unified molding for a thick cosmetic chest by using gas-assisted injection molding. CAE analysis was carried out to design the part and the gas channel without inducing sink marks. And based on the part weight measurement, the processing parameters to control gas penetration percentage were chosen through the method of design of experiments. A thick cosmetic chest was successfully produced using the gas assist technology. The sink mark issue associated with the conventional injection molded parts was resolved. Weight savings and cycle-time reduction were also achieved.

  • PDF

가스사출성형을 이용한 두꺼운 박스형 제품의 일체화 성형 연구 (A Study on the Unified Molding for a Box Shaped Thick Part Using Gas-Assisted Injection Molding)

  • 이호상
    • 소성∙가공
    • /
    • 제10권5호
    • /
    • pp.402-410
    • /
    • 2001
  • The gas-assisted injection molding process is often perceived to be unpredictable, because of the extreme sensitivity of the gas. Since a slight change in design or process parameters can significantly change the resulting gas penetration, few designers and molders have the level of experience with the new gas-assisted injection molding process required for the development of new parts. This paper is concerned with the unified molding for a thick cosmetic chest by using gas-assisted injection molding. CAE analysis was carried out to design the part and the gas channel without inducing sink marks. And based on the part weight measurement, the processing parameters to control gas penetration percentage were chosen through the method of design of experiments. A thick cosmetic chest was successfully produced using the gas assist technology. The sink mark issue associated with the conventional injection molded parts was resolved. Weight savings and cycle-time reduction were also achieved.

  • PDF

농업가뭄대응을 위한 인공함양 시스템의 함양능력 평가 (Recharge Potential Assessment of Artificial Recharge System for Agricultural Drought Adaptation)

  • 이재영;김규범
    • 한국방재안전학회논문집
    • /
    • 제14권1호
    • /
    • pp.61-72
    • /
    • 2021
  • 최근 기후변화로 인한 가뭄발생으로 국지적인 물부족 문제 해결을 위해 안정적인 지하수를 활용한 물공급 방안의 필요성이 증가하고 있으며 이에 대한 대안으로 지하수 인공함양 기술이 대두되고 있다. 본 연구에서는 기상조건 및 목표취수량, 함양정의 주입량, 주입기간 등을 고려한 함양 시나리오를 반영하여 수치모델링을 통해 인공함양-취수 시스템의 함양능력 평가와 최적 운영조건을 도출하여 가뭄발생에 대비한 농업용수의 효율적인 공급과 안정적인 용수확보를 위한 정량적인 평가기법을 도출하고자 하였다. 이에 함양정의 함양능력을 평가하기 위해 물수지 분석으로부터 도출된 목표취수량을 고려한 총 주입량 10,000 ton의 조건하에서 주입 시나리오별(Case 1~4)로 주입정 및 관측정별 지하수위 변화를 모사한 결과 주입 후 유역 내 지하수위는 약 25~42일간 유지되는 것으로 나타났다. 이 중 Case 3의 경우 지표하 1 m 미만으로 지하수위가 상승하여 적정 주입량은 50 m3/day가 적절한 것으로 모사되었으며 함양수 주입에 의한 지하수위 상승에 따른 영향범위는 113.5 m로 예측되었다. 또한 함양 시나리오에 따른 하류부 저투수성 벽체(LPB) 설치 전후의 유역내 함양능력 변화는 설치 전 대비 지하수 저류량은 약 6배가량 증가하였고 지하수 체류시간은 약 4배 정도 증가하는 것으로 모사되었다. 본 연구결과는 향후 가뭄대응을 위한 안정적인 농업용수 공급 및 지속적인 수자원 확보에 크게 기여할 것으로 기대된다.

대수층 수리지질특성에 따른 인공함양시험 적용 방법에 관한 연구 (A Study on the Application Method of Artificial Injection Test according to the Hydraulic Conductivity of Aquifer)

  • 채동석;최진오;정현철;김창용
    • 지질공학
    • /
    • 제31권4호
    • /
    • pp.589-601
    • /
    • 2021
  • 본 연구에서는 지하공간 개발로 인해 발생하는 지하수위저하, 지반함몰 등의 문제를 해결하는 방법 중 하나인 인공함양기술에 있어 지하수 함양에 결정적인 역할을 하는 지표매질 특성인 수리전도도(hydraulic conductivity)에 관한 적용성에 대한 연구를 수행하였다. 경기도 이천에 위치한 인공함양시설의 설계조건을 동일하게 하여 양수시험과 주입시험을 수행하였다. 양수시험을 통해서는 지하수위를 회복하는데 있어 결정적인 역할을 하는 대수층의 수리상수값을 도출하였으며, 현장 대수층을 단순화 시킨 모델을 구축하여 양수시험 조건과 동일하게 적용한 부정류 해석을 수행하여 실측값과 모델값의 상관성을 검토한 결과 R2 = 0.78로 분석되었다. 동일한 조건으로 주입시험을 수행하였으며, 주입되는 지층은 실트질모래와 점토질모래로 구성된 퇴적층에서 시험을 진행하였다. 주입시험을 통해 측정된 결과를 통해 시간-수위 자료로부터 대수층의 매개변수를 결정하는 대표적 우물해석해인 Thiem의 공식을 활용하여 경험식을 유도하였으며, 유도된 경험식과 실측값의 상관분석을 수행한 결과 R2 = 0.99의 높은 상관성을 가지는 경험식을 유도하였다. 본 연구는 주입시험이 수행되기 어려운 지역에서 양수시험을 통해 결정된 대수층의 수리전도도를 활용할 경우, 특정 조건에서 신뢰도 높은 결과를 예측하는데 적절히 활용될 것으로 판단된다.

치과용 Lidocaine 28 앰플로 국소마취 하에 1차 봉합한 악안면 심부 관통성 열창 -증례 보고- (Primary Closure of Deep Penetrating Wounds under Local Anesthesia with Dental Lidocaine HCL 28 Ampules in Maxillofacial Regions -Report of two cases -)

  • 김종배;유재하
    • 대한치과마취과학회지
    • /
    • 제1권1호
    • /
    • pp.26-31
    • /
    • 2001
  • The wide deep penetrating wound of maxillofacial region should be early closed under emergency general anesthesia for the prevention of complications of bleeding, infection, shock & residual scars. But, if the emergency general anesthesia wound be impossible because of pneumoconiosis, obstructive pulmonary disease & hypovolemic shock, early primary closure should be done under local anesthesia by use of much amount of the anesthetic solution. The maximum dose of dental lidocaine (2% lidocaine with 1 : 100,000 epinephrine) is reported to 7 mg/kg under 500 mg (13.8 ampules) in normal adult. But the maximum permissible dose of dental lidocaine can be changed owing to the general health, rapidity of injection, resorption, distribution & excretion of the drug. The blood level of overdose toxicity is above $4.0{\mu}g/ml$ in central nervous & cardiovascular system. The injection of dental lidocaine 1-4 ampules is attained to the blood level of $1{\mu}g/ml$ in normal healthy adult. The duration of anesthetic action in the dental 2% lidocaine hydrochloride with 1 : 100.000 epinephrine is 45 to 75 minutes and the period to elimination is about 2 to 4 hours. Therefore, authors selected the following anesthetic methods that the first injection of 6 ampules is applied into the deeper periosteal layer for anesthetic action during 1 hour, the second injection into the deeper muscle & fascial layer, the third injection into the superficial muscle and fascial layer, the fourth injection into the proximal skin & subcutaneous tissue and the fifth final injection into the distal skin & subcutaneous tissue. The total 26-28 ampules of dental lidocaine were injected into the wound as the regular time interval during 5-6 hours, but there were no systemic complications, such as, agitation, talkativeness, convulsion and specific change of vital signs and consciousness.

  • PDF

THE LEVEL OF RESIDUAL MONOMER IN INJECTION MOLDED DENTURE BASE MATERIALS

  • Lee Hyeok-Jae;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.360-368
    • /
    • 2003
  • Statement of Problem: The residual monomer of denture base materials causes hypersensitivity on oral mucosa and intereferes with the mechanical properties of the cured resin. The amount of residual monomer is influenced by materials, curing cycle, processing method, and etc. Purpose: The aim of this study was to investigate the residual methyl methacrylate(MMA) content of injection molded denture base polymer, and to compare this with the self-cured resin and the conventional compression molded heat-cured resin. Materials and Methods: Disc shaped test specimens (50mm in diameter and 3mm thick) were prepared in a conventional flasking technique with gypsum molding. One autopolymerized denture base resins (Vertex Sc. Dentimex. Netherlands) and two heat-cured denture base resins (Vertex RS. Dentimex. Netherlands, Ivocap. Ivoclar Vivadent, USA) were used. The three types of specimens were processed according to the manufacturer's instruction. After polymerization, all specimens were stored in the dark at room temperature for 7 days. There were 10 specimens in each of the test groups. 3-mm twist drills were used to obtain the resin samples and 650mg of the drilled sample were collected for each estimation. Gas chromatography (Agillent 6890 Plus Gas Chromatograph, Agillent Co, USA) was used to determine the residual MMA content of 10 test specimens of each three types of polymer. Results: The residual monomer content of injection molded denture base resins was $1.057{\pm}0.141%$. The residual monomer content of injection molded denture base resins was higher than that of compression molded heat cured resin ($0.867{\pm}0.169%$). However, there was no statistical significant difference between two groups (p>0.01). The level of residual monomer in self cured resin($3.675{\pm}0.791$) was higher than those of injection molded and compression molded heat cured resins (p<0.01). Conclusion: With respect to ISO specification pass / fail test (2.2% mass fraction) of residual monomer, injection molding technique($1.057{\pm}0.141%$) is a clinically useful and safe technique in terms of residual monomer.

단기통 디젤엔진에서 다단 파일럿 분할 분사 전략이 연소 및 배기가스 특성에 미치는 영향 (Effects of Multi-stage Pilot Split Injection Strategy on Combustion and Emission Characteristics in a Single-Cylinder Diesel Engine)

  • 이형민
    • 한국산학기술학회논문지
    • /
    • 제21권7호
    • /
    • pp.692-698
    • /
    • 2020
  • 본 논문은 커먼레일 단기통 디젤엔진에서 다단 파일럿 분할 분사 전략이 연소 및 배기가스 배출특성에 미치는 영향을 분석하는 데 초점을 두었다. 실린더 내부 최고 압력과 열발생률은 단일분사 조건에서 가장 높았으며, 파일럿 분사량이 균등하게 분할되어 분사 횟수가 증가할수록 감소하는 경향으로 나타났다. IMEP, 엔진 토크 및 연소 효율은 1단 파일럿 분사 조건에서 가장 낮게 나타나는 특성을 보였으나, 다단 파일럿 분할 분사 전략 적용 시 증가하는 경향으로 분석되었다. COVIMEP는 연소 효율이 가장 낮은 1단 파일럿 분사 조건에서 가장 높았으며, 이는 연소 안정성이 낮다는 것을 의미한다. 배기가스 중 산소농도는 단일분사 조건에서 가장 낮았고, 이산화탄소는 가장 높게 배출되는 특성을 보였다. 다단 분할 분사 전략 적용 시 저온 연소과정이 진행되기 때문에 일산화탄소의 산화율은 낮아지게 되고 배출수준은 증가하는 특성을 보였다. 탄화수소는 국부적으로 농후한 혼합기가 형성되는 단일분사 조건에서 가장 높은 결과를 보였다. 질소산화물은 다단 파일럿 분할 분사 전략 중 3단 파일럿 분사 조건에서 55.6%까지 감소하는 특성을 보였다.

Biphenyldimethyl dicarboxylate(DDB)가 Ethanol 유발 간독성 흰쥐에서의 지질 과산화와 Oxygen Free Radical 제거 효소 활성도 및 간기능에 미치는 영향 (Effects of Biphenyldimethyl dicarboxylate(DDB) on the Lipid Peroxidation, Oxygen Free Radical Scavenging Enzymes Activities and Hepatic Functions in Ethanol-induced Hepatotoxic Rats)

  • 송호연;하경란;고현철;신인철;서대규
    • 대한약리학회지
    • /
    • 제30권2호
    • /
    • pp.217-225
    • /
    • 1994
  • In an attempt to define the effects of Biphenyldimethyl dicarboxylate(DDB) on the lipid peroxidation, oxygen free radical scavenging enzymes activities and hepatic functions in ethanol-induced hepatotoxic rats, we studies malondialdehyde(MDA) level and the activities of catalse, superoxide dismutase(SOD), glutamic-oxaloacetic transaminase(GOT) and glutamic-pyruvic transaminase(GPT) in liver of the rats at 24, 48 and 72 hr after the injection of ethanol and DDB. Sprague-Dalwey albino rats weighing 250 to 280gm were injected intraperitoneally with ethanol(2.5 gm/kg ) only and ethanol plus DDB(300mg/kg ). The result obtained can be summarized as follows : 1) The group treated with ethanol showed significantly higher MDA level and lower catalase and SOD activities at 24, 48 and 72hr after the injection as compared with that of control group. 2) The group treated with ethanol showed significantly higher GOT and GPT activities at 24, 48 and 72hr after the injection as compared with that of control group. 3) The group treated with ethanol plus DDB showed significantly lower MDA level and higher catalase and SOD activities at 24, 48 and 72 hr after the injection as compared with that of ethanol group. 4) The group treated with ethanol plus DDB showed significantly lower GOT and GPT activities at 24, 48 and 72 hr after the injection as compared with that of ethanol group. These results suggest that the excessive oxygen free radicals resulting from the depression of the activities of catalase and superoxide dismutase is an important determinant in pathogenesis of ethanol-induced hepatotoxicity and DDB has antioxidant effects.

  • PDF

흡수격자를 갖는 DFB 레이저의 제작 및 특성 (Fabrication and Characteristics of DFB Laser with Absorption Grating)

  • 이형종
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.73-78
    • /
    • 1990
  • 1.3${\mu}{\textrm}{m}$ DFB with absorption grating of 1.55${\mu}{\textrm}{m}$ InGaAsP layer was fabricated. This new type of DFB laser shows self-plusation for DC operation. At low level of injection the relation between the pulsation frequency and the injection current shows similar behavior with the relaxation oscillation of ordinary laser and at high level of injection the pulsation frequency decreases compared to the relaxation oscillation. Period doubling, period 3 and 4 were observed for AC modulation. In case of period doubling the waveform shows only one pulse within a period without any accompanying subsidiary pulses and the oscillation frequency was quite stable. The pulse widths as short as 58.5 ps was achieved with AC modulation. We propose the time division multiplexing application of this kind of DFB laser.

  • PDF

플라스틱 용기 성형을 위한 스택금형 제작에 관한 연구 (Development of 2 Level × 4 Cavity Stack Mold for Plastic Container)

  • 정우철;허영무;신광호;윤길상
    • Design & Manufacturing
    • /
    • 제1권1호
    • /
    • pp.33-37
    • /
    • 2007
  • In recent, the demand of high-productivity injection mold increases because of the growth of international packaging market. The increase of productivity leads to the large-sized injection molding machine and peripheral devices. For solving this problem, the stack mold which is based on the existing machine and device is studied in advanced countries actively. In this study, as the preliminary research of stack mold development, the stack mold which has 2 Level ${\times}4$ Cavity is designed and manufactured. Besides, the motion and structural analysis are executed to verify the stability of developed stack mold.

  • PDF