• Title/Summary/Keyword: Initial contact angle

Search Result 122, Processing Time 0.03 seconds

A Selection of Initial Contact Angle of Automotive Wheel Bearing Units (차륜용 베어링 유니트의 초기 접촉각 선정)

  • 안태길;이상훈;현준수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.1
    • /
    • pp.162-167
    • /
    • 2002
  • An automotive wheel bearing is one of the most important components to guarantee the service life of a passenger car. The endurance life of a bearing is affected by many parameters such as material properties, heat treatment, lubrication conditions, temperature, loading conditions, bearing geometry, internal clearance and so on. In this paper, we analyze the relation between loads and deformations of wheel bearing units. On the basis of it, we calculate the endurance life of wheel bearing units and suggest a method to determine the initial contact angle to achieve a maximum endurance life with considering stress concentration.

Wetting Properties of Biopolyester Films Prepared by Thermo-Compression Method

  • Rhim, Jong-Whan;Hong, Seok-In
    • Food Science and Biotechnology
    • /
    • v.16 no.2
    • /
    • pp.234-237
    • /
    • 2007
  • Water resistance of three biopolyester films, such as poly-L-lactate (PLA), poly-hydroxybutyrate-co-valerate (PHBV), and Ecoflex, and low density polyethylene (LDPE) film was investigated by measuring contact angle of various probe liquids on the films. The properties measured were initial contact angle of water, dynamic change of the water contact angle with time, and the critical surface energy of the films. Water contact angle of the biopolyester films ($57.62-68.76^{\circ}$) was lower than that of LDPE film ($85.19^{\circ}$) indicating biopolyester films are less hydrophobic. The result of dynamic change of water contact angle also showed that the biopolyester films are less water resistant than LDPE film, but much more water resistant than cellulose-based packaging materials. Apparent critical surface energy for the biopolyester films (35.15-38.55 mN/m) was higher than that of LDPE film (28.59 mN/m) indicating LDPE film is more hydrophobic.

Wetting properties between silver-copper-titanium braze alloy and hexagonal boron nitride

  • Sechi, Yoshihisa;Matsumoto, Taihei;Nakata, Kazuhiro
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.205-209
    • /
    • 2009
  • Wetting properties between silver-copper-titanium braze alloys with different titanium contents up to 2.8 mass% and hexagonal boron nitride ceramics were investigated using sessile drop method at 1123K in Argon. The final contact angle is less than $30^{\circ}$ when the Ti content was over 0.41 mass%. Meanwhile, the contact angle curves show different behavior. In case of using braze alloy containing 2.8 mass% of titanium, the initial contact angle is acute angle just after the melting of braze. In case of brazes containing titanium less than 2.26 mass%, the contact angle is larger than $90^{\circ}$ at the beginning and slowly decreases to acute angle. The reaction layer of titanium nitride is observed at the interface. In addition, the reaction of Ti in the braze and N in the bulk h-BN seemed to show diffusion limited spreading.

  • PDF

Study on the Effect of Contact Angles of Elastic Rubber Impression Materials on the Surface of Working Cast (탄성 고무인상재의 접촉각이 작업모형 표면에 미치는 영향)

  • Kim, Joo-Won
    • Journal of dental hygiene science
    • /
    • v.10 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • This study was begun to search effect of contact angles of elastic rubber impression materials on the surface of working cast. Of elastic rubber impression materials with a Type III consistency, such as polysulfide, polyether and addition silicone, we selected one and then measured the contact angle after dripping a distilled water 3.3ml. Then, after pouring a dental anhydrite in three types of impression materials, we prepared a working cast and then examined its surface. Contact angle was measured using a full automatic contact angle measuring system (DM-700, KYOWA, Japan), and the surface of working cast was observed using a field emission scanning electron microscope (JSM-6700F, JEOL Ltd., JAPAN). The following results were obtained: 1) $Mean{\pm}SD$ (SD: standard deviation) of the initial contact angles were $91.3{\pm}20.5^{\circ}$ in the addition silicone materials, $90.0{\pm}2.2^{\circ}$ in the polyethers and $101.5{\pm}2.3^{\circ}$ in the polysulfides. These results indicate that mean values were similar but standard deviations of the three materials showed a great discrepancy. 2) As the time elapsed, addition silicone materials were found to have a contact angle decreased abruptly as compared with the remaining two types. That is, the initial contact angle was $91.3^{\circ}$ and it was abruptly decreased to $29.4^{\circ}$ after 25 seconds. 3) In the polyethers, the initial contact angle was $101.5^{\circ}$ and it was decreased to $90.7^{\circ}$ after 25 seconds. In the polysulfides, however, the initial contact angle was $90.0^{\circ}$ and it was $84.2^{\circ}$ after 25 seconds. This showed almost no changes in the initial contact angles. Moreover, its magnitude was greater than that seen in additional silicones. 4) There were significant differences in the contact angles between the three types of elastic rubber impression materials as the time elapsed (p<0.001). On an observation on the surface of working cast, addition silicone materials were found to have the most dense surface. This was followed by polysulfides and polyethers in a descending order.

Effect of Native Oxide Layer on the Water Contact Angle to Determine the Surface Polarity of SiC Single Crystals (접촉각 측정방법을 이용한 SiC 단결정의 극성표면 판별에 있어 자연산화막의 영향)

  • Park, Jin Yong;Kim, Jung Gon;Kim, Dae Sung;Yoo, Woo Sik;Lee, Won Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.245-248
    • /
    • 2020
  • The wettability of silicon carbide (SiC) crystal, which has 6H-SiC and 4H-SiC regions prepared using the physical vapor transport (PVT) method, is quantitatively analyzed using dispensed deionized (DI) water droplets. Regardless of the polytypes in SiC, the average of five contact angle measurements showed a difference of about 6° between the Si-face and C-face. The contact angle on the Si-face (C-face) is measured after the removal of the native oxide using BOE (6:1), and revealed a significant decrease of the contact angle from 74.9° (68.4°) to 47.7° (49.3°) and from 75.8° (70.2°) to 51.6° (49.5°) for the 4H-SiC and 6H-SiC regions, respectively. The contact angle of the Si-face recovered over time during room temperature oxidation in air; in contrast, that of the C-face did not recover to the initial value. This study shows that the contact angle is very sensitive to SiC surface polarity, specific surface conditions, and process time. Contact angle measurements are expected to be a rapid way of determining the surface polarity and wettability of SiC crystals.

The Comparison of Characteristics of Foot pressure between Treadmill and Ground walking in Normal person (정상인의 평지보행과 트레드밀 보행 시 족저압의 특성 비교)

  • Kim, Ji-Hye;Oh, Tae-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.1
    • /
    • pp.53-61
    • /
    • 2010
  • Purpose : The purpose of this study is to compare the distribution of foot pressure, knee and ankle joint angle between treadmill walking and ground walking in normal person. Methods : 18 Person of subject has participated this study, let subject to walk in ground and treadmill in order to gain data of foot distribution and knee, ankle joint angle using by parotec system. and Dartfish system. Walking velocity was constrained by 2Km/h and more 10sec. Date analysis was used by paired-t test using SPSS/PC statistical programs for window. Results : Result show that total contact times has shown symmetry between both legs, and more increase of left foot pressure in treadmill walking. Foot pressure of treadmill walking was significantly decreased in right hind foot and fore foot and hallux area. The ankle joint angle of treadmill walking was significantly decreased in initial contact phase. Conclusion : Results of this study show that foot pressure of treadmill walking was more decreased than ground walking in right hind foot and fore foot, hallux area. And the ankle joint angle of treadmill walking was significantly decreased in initial contact phase.

Experimental Study on the Contact Force of Rubber Seals for a Ball Bearing (베어링 용 고무시일의 접촉력에 관한 실험적 연구)

  • 전인기;심우전;최인혁;김청균
    • Tribology and Lubricants
    • /
    • v.9 no.1
    • /
    • pp.32-37
    • /
    • 1993
  • The equations are derived for the evaluation of the axial contact forces. The contact forces of rubber seals are analyzed as a function of the ratio of real contact length, the thickness of seal lip, the inclined angle of seal lip, and the interference between the edge of seal lip and the rotating inner ring. The experimental apparatus is developed for the test of seal lip contact force. The data for designing rubber seals are presented in terms of the ratio of real contact length, initial inclined lip angle, lip thickness. and the interference. The results obtained from the derived equation for the contact force are in good agreement with the experimental results.

Characteristics for Nanofluid Droplet Evaporation on Heated Surface at Boiling Temperature of Base Liquid (비등점의 가열 표면에서 나노유체 액적의 증발 특성)

  • Kim, Dae Yun;Jung, Jung-Yeul;Lee, Seong Hyuk
    • Journal of ILASS-Korea
    • /
    • v.20 no.4
    • /
    • pp.236-240
    • /
    • 2015
  • This study aims to experimentally investigate the evaporation characteristics of nanofluid droplet on heated surface at boiling temperature of DI-water. In particular, textured surface was used to examine the effect of wettability on evaporation. At the initial stage of evaporation process, dynamic contact angle (DCA) of nanofluid droplet with 0.01 vol.% concentration on textured surface rapidly increased over its equilibrium contact angle by generated large bubble inside the droplet due to lower wettability. However, contact angle of nanofluid droplet with higher concentration on textured surface decreased with surface tension. In addition, total evaporation time of droplet on textured surface was considerably delayed due to reduction of contact area between droplet and solid surface. Thus, evaporation characteristics were highly affected by the nanofluid concentration and surface wettability.

A Study on the Contact Force of Rubber Seals for Ball Bearings (볼 베어링용 고무시일의 접촉력 해석에 관한 연구)

  • 김청균;전인기;최인혁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2261-2267
    • /
    • 1992
  • The equations are derived for the evaluation of the axial contact force. The contact forces for rubber seals are analyzed as a function of the ratio of real contact length, the thickness of seal lip, the inclined angle of seal lip, and the interference between the edge of seal lip and the rotating inner ring. The design data for rubber seals are presented in terms of the ratio of real contact length, initial inclined lip angle, lip thickness and the interference. The calculated results show that the deflected interference and the circumferential stress cause considerable change of contcat forces for the low sealed pressure.

A Study on the Kinematic Variables in Different Safety Shoes and Applying Insole During Walking (안전화 형태와 인솔착용 유무에 따른 보행동작시 하지부위에 대한 운동학적 부하 분석)

  • Kim, Jung-Jin;Choi, Sang-Bock;Cha, Sang-Eon
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.1
    • /
    • pp.35-45
    • /
    • 2008
  • This study was performed to compare the kinematics among three different safety shoes(type 1: ergonomically designed and high quality shoes, 2: curved and cushioned safety shoes, and 3: regular safety shoes) and to find the effect of insole during walking. Ten healthy subjects were recruited for this study. The range of motion of knee and ankle joint, angle of rear foot and angle of heel contact were measured using a three dimensional motion analysis system. In the second peak, the angle of heel contact showed statistically significant difference between safety shoes and insole, however, there was no statistical significance among three different safety shoes. The angle of ankle increased significantly at initial contact, first peak, the second peak and the toe off phase compared with type 1 and 2 safety shoes, and the angle of ankle showed statistically significant difference between with and without applying the insole. During the first peak, the second peak and the toe off phase, the angle of knee was statistical significance between safety shoes and insole. In heel contact, the angles of Achilles' tendon showed statistically significant difference between safety shoes and insole. The rear foot angles showed statistically significant difference between safety shoes and insole during heel contact and early heel contact. These results suggest that the type 1 safety shoes were superior to others in the statistics, and applying insole could be a possible method to prevent fatigue of lower extremity and musculoskeletal disorders. Further studies are needed to find the effect of ergonomically designed safety shoes and insole on practical value in prevention of musculoskeletal disorder, fatigue and satisfaction of workers.