• 제목/요약/키워드: Infrared light source

검색결과 114건 처리시간 0.032초

INTELLIGENT MIRROR ADJUSTMENT SYSTEM USING A DRIVER′S PUPILS

  • Rho, K.H.;Han, M.H.
    • International Journal of Automotive Technology
    • /
    • 제5권4호
    • /
    • pp.277-285
    • /
    • 2004
  • This paper describes an intelligent mirror adjustment system that rotates a pair of side mirrors and the room mirror of a car to the optimal position for a driver by using the location of the driver's pupils. A stereo vision system measures the three-dimensional coordinates of a pair of pupils by analyzing the input images of stereo B/W CCD cameras mounted on the instrument panel. This system determines the position angle of each mirror on the basis of information about the location of the pupils and rotates each mirror to the appropriate position by mirror actuators. The vision system can detect the driver's pupils regardless of whether it is daytime or nighttime by virtue of an infrared light source. Information about the pair of nostrils is used to improve the correctness of pupil detection. This system can adjust side mirrors and the room mirror automatically and rapidly by a simple interface regardless of driver replacement or driver's posture. Experiment has shown this to be a new mirror adjustment system that can make up for the weak points of previous mirror adjustment systems.

운전자 눈동자 위치를 이용한 이러 자동 조절 시스템 (Automatic Mirror Adjustment Systems Using the Location of the Driver`s Pupils)

  • 노광현;박기현;조준수;한민홍
    • 제어로봇시스템학회논문지
    • /
    • 제7권6호
    • /
    • pp.523-531
    • /
    • 2001
  • This paper describes and automatic mirror adjustment system that rotates a pair of side mirrors and the room mirror of a car to the optimal position for a driver by using the locating of the driver\`s pupils. A stereo vision system measures 3D coordinates of a pair pupils by analyzing the input images of stereo B/W CCD cameras mounted on the instrument panel. this system determines the position angle of each mir-ror on the basis of information about the location of the pupils and rotates each mirror to the appropriate po-sition by mirror actuators. The vision system can detect the driver\`s pupils regardless of whether it is day-time or nighttime by virtue of an infrared light source. information about the pair of nostrils in used to im- prove the correctness of pupil detection. This system can adjust side mirrors and the room mirror automati- cally and rapidly by a simple interface regardless of driver replacement of driver\`s posture. Experiment has shown this to be a new mirror adjustment system that can make up for the weak points of previous mirror adjustment systems.

  • PDF

A Study on the Design of a Current Type ROIC for Uncooled Bolometer Thermal Image Sensor Using Correlated Double Sampling

  • Kwak, Sang-Hyeon;Lee, Po;Jung, Eun-Sik;Sung, Man-Young
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.7-8
    • /
    • 2009
  • In the presence of infrared light, a CMOS Readout IC (ROIC) for a microbolometer typed infrared sensor detects the voltage or current that is caused by the changing in resistance in the bolometer sensor. A serious problem in designing the ROIC is how the value of the bolometer and reference resistors vary because of variations in manufacturing process. Since different pixel have different, resistance values, sensor operations must contend with fixed pattern noise (FPN) problems. In this paper, we propose a novel technique to compensate for the fluctuation in reference resistance by tiling into account the process variation. By using constant current source basing and correlated double sampling, we solved FPN.

  • PDF

열화상 비파괴 검사법을 이용한 도로포장 결함 검출 (Detecting of the defects of pavement of a road by using infrared thermography)

  • 심준기;김기현
    • 복합신소재구조학회 논문집
    • /
    • 제6권3호
    • /
    • pp.69-76
    • /
    • 2015
  • The purpose of this paper is to find an limitation to detect the defect of damaged asphalt pavement structures for infrared thermography. We use heat source of a natural light to detect the defect efficiently. The heat source was applied to the asphalt specimens. Four asphalt specimens were used: one was the asphalt containing depth of 1cm internal timber, two was the asphalt containing depth of 2cm internal void, Three was the asphalt containing depth of 3cm internal timber and four was not the asphalt containing internal timber. It was found that the depth of 3cm internal timber could be detected by this method. In addition, we used the image processing to make the damage zone displayed clear in the image obtained from the thermographic operation.

3-5 $\mu m$ 적외선 흡수체를 가진 전면 건식 식각된 서모파일과 NDIR $CO_2$ 가스 센서의 응용 (A Front-side Dry-Etched Thermopile Detector with 3-5 $\mu m$ Infrared Absorber and Its Application to Novel NDIR $CO_2$ Gas Sensors)

  • 유금표;김시동;최우석;;민남기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1470-1471
    • /
    • 2008
  • We present a front-side micromachined thermopile with high sensitivity in the 3-5${\mu}m$ window, and discuss its application to a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. The micromachined thermopile shows a measured sensitivity of 30 mV/W and a $D^*$ of $0.3{\times}10^8cm^{\surd}Hz/W$. Using this newly fabricated thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF

Dust Scattering in Turbulent Media: Correlation between the Scattered Light and Dust Column Density

  • Seon, Kwang-Il;Witt, Adolf N.
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.59.2-59.2
    • /
    • 2014
  • Radiative transfer models in a spherical, turbulent interstellar medium (ISM), in which the photon source is situated at the center, are calculated to investigate the correlation between the scattered light and the dust column density. The medium is modeled using fractional Brownian motion structures that are appropriate for turbulent ISM. The correlation plot between the scattered light and optical depth shows substantial scatter and deviation from simple proportionality. It was also found that the overall density contrast is smoothed out in scattered light. In other words, there is an enhancement of the dust-scattered flux in low-density regions, while the scattered flux is suppressed in high-density regions. The correlation becomes less significant as the scattering becomes closer to being isotropic and the medium becomes more turbulent. Therefore, the scattered light observed in near-infrared wavelengths would show much weaker correlation than the observations in optical and ultraviolet wavelengths. We also find that the correlation plot between scattered lights at two different wavelengths shows a tighter correlation than that of the scattered light versus the optical depth.

  • PDF

음향광학 파장선택 필터 기반 파장훑음 레이저를 이용한 시간-인코딩 된 근적외선 흡광도 측정 비교 연구 (Time-encoded Near-infrared (NIR) Spectroscopic Comparison of Absorbance Measurement Using an Acousto-optic NIR Swept Laser Source)

  • 장한솔;김경훈;한가희;조재두;김창석
    • 한국광학회지
    • /
    • 제28권1호
    • /
    • pp.22-27
    • /
    • 2017
  • 본 논문에서는 음향광학 파장선택 필터(acousto-optic tunable filter) 기반의 파장훑음 레이저(wavelength swept laser)를 이용한 시간-인코딩 근적외선 분광 기술(time-encoded near-infrared spectroscopy)을 제안하였다. 파장훑음 레이저는 800 nm 근처 영역에서 이득 스펙트럼을 가지는 반도체 광 증폭기(semiconductor optical amplifier)를 기반으로 제작되었으며, 음향광학 파장선택 필터를 공진기 내부에 삽입함으로써 음향광학 파장선택 필터에 인가되는 전기적 라디오주파수에 따라 출력 파장을 선택할 수 있도록 하였다. 본 연구에서는 종래의 기술인 백색광 분광기 기반의 검출부 분광 근적외선 분광 기술과 제안된 파장훑음 레이저 기반의 광원부 분광 근적외선 분광 기술을 각각 이용하여 근적외선 흡수 염료 샘플의 흡광도를 각기 측정하여 실험적으로 비교함으로써 본 연구에서 제안하는 음향광학 파장선택 필터 기반 파장훑음 레이저를 이용한 근적외선 분광 기술의 특성을 증명하였다.

수종 광중합 복합 레진의 중합 깊이와 광조사 시간에 따른 중합률에 관한 연구 (A STUDY ON THE DEGREE OF CONVERSION OF LIGHT CURING COMPOSITE RESIN ACCORDING TO THE DEPTH OF CURE AND LIGHT CURING TIME)

  • 김경현;권오승;김현기;백규철;엄정문;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.35-60
    • /
    • 1997
  • Physical properties of composite resins such as strength, resistance to wear, discoloration, etc, depend on the degree of conversion of the resin components. The clinical behavior of restorative resins varies brand to brand. Part of this variation is associated with the filler and differences in the polymer matrix. The polymer matrix of resins may differ because the involved monomers are dissimilar and because of variation in the catalyst system. The purpose of this study was to evaluate the degree of conversion of the composite resins according to the depth of cure and light curing time. 7mm diameter cylindrical aluminum molds were filled with each of five different hybrid light curing composite resins(Z-100, Charisma, Herculite XRV, Prisma TPH, Veridonfil) on the thin resin films. The molds were 1mm, 2mm, 3mm, 4mm, and 5mm in depth to produce resin films of various heights. Each sample was given 20sec, 40sec, and 60sec illumination with a light source. The degree of conversion of carbon double bonds to single bonds in the resin films was examined by means of Fourier Transform Infrared Spectrometer. The results were obtained as follows; 1. There was difference in the degree of conversion among five light curing composite resins according to the depth of cure for 20sec, 40sec, and 60sec illumination with light source with statistical significance(P<0.05). 2. Five light curing composite resins show lower degree of conversion at surface of the resin than depth of 1mm. 3. The degree of conversion of five light curing composite resins was siginificantly reduced from the maximum for the resin film when the light passed through as little as 1mm of each composite. 4. The degree of conversion of five light curing composite resins decrease significantly at the depth of 4mm, and polymerization was not occured at the depth of 5mm except for Prisma TPH. 5. The degree of conversion of five light curing composite resins was increased with increased light curing time, and there was no significant differences in the degree of conversion above 4mm in Z-100, 3mm in Charisma, and at depth of 5mm in Herculite XRV and Veridonfil(P>0.05).

  • PDF

광학 영상기를 위한 실시간 영상 신호 처리에 관한 연구 (Video Rate Image Signal Processing for Optical Coherence Tomography)

  • 나지훈;이병하;이창수
    • 제어로봇시스템학회논문지
    • /
    • 제10권3호
    • /
    • pp.239-248
    • /
    • 2004
  • Optical coherence tomography(OCT) is high resolution imaging system which can see the cross section of microscopic organs in the living tissue. In this paper, we analyze the relation between the light source and the resolution of modulated signal in Michelson interferometer. We construct 1-D OCT signal processing hardware such as amplifiers, filters, and demodulate electronic signals from the photo detector. In order to get 2-D OCT image, the synchronization among optical delay line, sample stage and A/D converter is dealt with. In experiments, we verify analog and digital signal processing blocks which apply to the stacks of glasses. Finally we aquire high resolution 2-D OCT image with respect to the onion tissue. We expect that this result can be applied to the medical instrument through performance improvement.

솔라시뮬레이터의 램프뱅크 설계에 관한 연구 (A STUDY ON LAMP BANK DESIGN OF SOLAR SIMULATOR)

  • 백상화
    • 한국전산유체공학회지
    • /
    • 제17권3호
    • /
    • pp.45-52
    • /
    • 2012
  • This paper is a study on the design of the solar lamp bank which is a very important part of the solar simulator with the commercial metal halide lamps and infrared lamps. Lamp Bank is designed by the lamp bank design program based on point light source theory. The reliability of the program for lamp bank design is verified through irradiance variation experiments of a kind of lamp according to horizontal distance. Solar lamp bank facilitates heat distribution and satisfies the irradiance in the three wave length which test guidelines require. The shape of the ceiling board next to the lamp bank to promote the lamp cooling efficiency and to reduce temperature deviation and air velocity deviation in the chamber is so creative. The ceiling board of partial closed type is the best among several types.