• Title/Summary/Keyword: Infrared imaging

Search Result 767, Processing Time 0.023 seconds

Discussion of Preliminary Design Review for MIRIS, the Main Payload of STSAT-3

  • Han, Won-Yong;Jin, Ho;Park, Jang-Hyun;Nam, Uk-Won;Yuk, In-Soo;Lee, Sung-Ho;Park, Young-Sik;Park, Sung-Jun;Lee, Dae-Hee;Ree, Chang-H.;Jeong, Woong-Seob;Moon, Bong-Kon;Cha, Sang-Mok;Cho, Seoung-Hyun;Rhee, Seung-Woo;Park, Jong-Oh;Lee, Seung-Heon;Lee, Hyung-Mok;Matsumoto, Toshio
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.27.1-27.1
    • /
    • 2008
  • KASI (Korea Astronomy and Space Science Institute) is developing a compact wide-field survey space telescope system, MIRIS (The Multi-purpose IR Imaging System) to be launched in 2010 as the main payload of the Korea Science and Technology Satellite 3. Through recent System Design Review (SDR) and Preliminary Design Review (PDR), most of the system design concept was reviewed and confirmed. The near IR imaging system adopted short F/2 optics for wide field low resolution observation at wavelength band 0.9~2.0 um minimizing the effect of attitude control system. The mechanical system is composed of a cover, baffle, optics, and detector system using a $256\times256$ Teledyne PICNIC FPA providing a $3.67\times3.67$ degree field of view with a pixel scale of 51.6 arcsec. We designed a support system to minimize heat transfer with Muti-Layer Insulation. The electronics of the MIRIS system is composed of 7 boards including DSP, control, SCIF. Particular attention is being paid to develop mission operation scenario for space observation to minimize IR background radiation from the Earth and Sun. The scientific purpose of MIRIS is to survey the Galactic plane in the emission line of Pa$\alpha$ ($1.88{\mu}m$) and to detect the cosmic infrared background (CIB) radiation. The CIB is being suspected to be originated from the first generation stars of the Universe and we will test this hypothesis by comparing the fluctuations in I (0.9~1.2 um) and H (1.2~2.0 um) bands to search the red shifted Lyman cutoff signature.

  • PDF

A $64\times64$ IRFPA CMOS Readout IC for Uncooled Thermal Imaging (비냉각 열상장비용 $64\times64$ IRFPA CMOS Readout IC)

  • 우회구;신경욱;송성해;박재우;윤동한;이상돈;윤태준;강대석;한석룡
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.5
    • /
    • pp.27-37
    • /
    • 1999
  • A CMOS ReadOut Integrated Circuit (ROlC) for InfraRed Focal Plane Array (IRFPA) detector is presented, which is a key component in uncooled thermal imaging systems. The ROIC reads out signals from $64\times64$ Barium Strontium Titanate (BST) infrared detector array, then outputs pixel signals sequentially after amplifying and noise filtering. Various design requirements and constraints have been considered including impedance matching, low noise, low power dissipation and small detector pitch. For impedance matching between detector and pre~amplifier, a new circuit based on MOS diode structure is devised, which can be easily implemented using standard CMOS process. Also, tunable low pass filter with single~pole is used to suppress high frequency noise. In additions, a clamping circuit is adopted to enhance the signal~to-noise ratio of the readout output signals. The $64\times64$ IRFPA ROIC is designed using $0.65-\mu\textrm{m}$ 2P3M (double poly, tripple metal) N~Well CMOS process. The core part of the chip contains 62,000 devices including transistors, capacitors and resistors on an area of about $6.3-mm\times6.7-mm$.

  • PDF

과학기술위성 3호 주탑재체 MIRIS 개발 현황

  • Han, Won-Yong;Lee, Dae-Hui;Park, Yeong-Sik;Jeong, Ung-Seop;Lee, Chang-Hui;Mun, Bong-Gon;Park, Seong-Jun;Cha, Sang-Mok;Pyo, Jeong-Hyeon;Ga, Neung-Hyeon;Lee, Deok-Haeng;Park, Jang-Hyeon;Seon, Gwang-Il;Nam, Uk-Won;Yang, Sun-Cheol;Lee, Seung-U;Park, Jong-O;Lee, Hyeong-Mok;Toshio, Matsumoto
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.55.2-55.2
    • /
    • 2010
  • 한국천문연구원은 과학기술위성 3호의 주탑재체인 다목적 적외선영상시스템(Multipurpose Infra-Red Imaging System, MIRIS)을 개발하고 있다. 이 연구개발 사업은 2007년 교육과학기술부의 과학위성 3호 사업 주탑재체 공모를 통하여 10여개의 후보 탑재체 제안서 중에서 최종적으로 채택되었고, 2011년 발사를 목표로, 3년 동안의 연구개발 기간을 거쳐 현재 비행모델 (FM, Flight Model) 개발이 진행 중이다. MIRIS는 한국천문연구원이 개발하여 2003년 발사에 성공한 과학위성 1호 주탑재체인 원자외선 영상분광기 (FIMS, Far ultra-violet IMaging Spectroscope)에 이어 국내에서 자체 개발되는 두 번째 우주망원경이다. MIRIS는 우주공간에서 0.9~2 micron 사이 적외선 영역의 파쉔 알파 방출선 (Paschen Alpha Emiision Line)과 광대역 I, H 파장영역을 관측할 예정이다. 주요 과학임무로는 아직까지 국제 천문학계에서 잘 알려지지 않은 우리은하 내부에 분포한 고온 플라즈마 (Warm Ionized Medium, WIM)의 기원 연구와 아울러 우리은하 성간난류(Interstellar Turbulence)의 특성 및 적외선 우주배경복사의 (Cosmic Infrared Background; CIB) 거대구조 등을 관측연구할 예정이다. 특히 MIRIS는 저온상태 (절대온도 77K, 약 $-200^{\circ}C$)에서 우주공간 관측을 수행할 예정이므로, 국내에서는 연구기반이 취약한 극저온 광학계 및 기계부 설계기술, 극저온 냉각기술 및 열해석 설계기술과 적외선 센서기술 및 자료처리 기술 등 관련기술을 개발하고 있으며 이러한 기반기술을 바탕으로, 아직까지 국내에서 시도된 바 없는 적외선우주망원경 개발을 통하여, 우리나라의 관련 우주기술 분야의 기초원천 기술로서 크게 활용될 것으로 기대하고 있다.

  • PDF

Study of a Brain Tumor and Blood Vessel Detection System Using Multiple Fluorescence Imaging by a Surgical Microscope (수술현미경에서의 다중형광영상을 이용한 뇌종양과 혈관영상 검출 시스템 연구)

  • Lee, Hyun Min;Kim, Hong Rae;Yoon, Woong Bae;Kim, Young Jae;Kim, Kwang Gi;Kim, Seok Ki;Yoo, Heon;Lee, Seung Hoon;Shin, Min Sun;Kwon, Ki Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • In this paper, we propose a microscope system for detecting both a tumor and blood vessels in brain tumor surgery as fluorescence images by using multiple light sources and a beam-splitter module. The proposed method displays fluorescent images of the tumor and blood vessels on the same display device and also provides accurate information about them to the operator. To acquire a fluorescence image, we utilized 5-ALA (5-aminolevulinic acid) for the tumor and ICG (Indocyanine green) for blood vessels, and we used a beam-splitter module combined with a microscope for simultaneous detection of both. The beam-splitter module showed the best performance at 600 nm for 5-ALA and above 800 nm for ICG. The beam-splitter is flexible to enable diverse objective setups and designed to mount a filter easily, so beam-splitter and filter can be changed as needed, and other fluorescent dyes besides 5-ALA and ICG are available. The fluorescent images of the tumor and the blood vessels can be displayed on the same monitor through the beam-splitter module with a CCD camera. For ICG, a CCD that can detect the near-infrared region is needed. This system provides the acquired fluorescent image to an operator in real time, matching it to the original image through a similarity transform.

MODIS-estimated Microphysical Properties of Clouds Developed in the Presence of Biomass Burning Aerosols (MODIS 관측자료를 이용한 러시아 산불 영향 하에 발달한 구름의 미세 물리적 특성 연구)

  • Kim, Shin-Young;Sohn, Byung-Ju
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.4
    • /
    • pp.289-298
    • /
    • 2008
  • An algorithm was developed to retrieve both cloud optical thickness and effective particle radius considered the aerosol effect on clouds. This study apply the algorithm of Nakajima and Nakajima (1995) that is used to retrieve cloud optical thickness and effective particle radius from visible, near infrared satellite spectral measurements. To retrieve cloud properties, Look-up table (LUT) was made under different atmospheric conditions by using a radiative transfer model. Especially the vertical distribution of aerosol is based on a tropospheric aerosol profile in radiative transfer model. In the case study, we selected the extensive forest fire occurred in Russia in May 2003. The aerosol released from this fire may be transported to Korea. Cloud properties obtained from these distinct atmospheric situations are analysed in terms of their possible changes due to the interactions of the clouds with the aerosol particle plumes. Cloud properties over the East sea at this time was retrieved using new algorithm. The algorithm is applied to measurements from the MODerate Resolution Imaging Spectrometer (MODIS) onboard the Terra spacecrafts. As a result, cloud effective particle radius was decreased and cloud optical thickness was increased during aerosol event. Specially, cloud effective particle radius is hardly greater than $20{\mu}m$ when aerosol particles were present over the East Sea. Clouds developing in the aerosol event tend to have more numerous but smaller droplets.

Nondestructive Deterioration Diagnosis and Environmental Investigation of the Stupa of the Buddhist Monk Soyo in Baegyangsa Temple, Jangseong (장성 백양사 소요대사탑의 비파괴 훼손도 진단과 입지환경 검토)

  • Kim, Yuri;Lee, Myeong Seong;Chun, Yu Gun;Lee, Mi Hye;Jwa, Yong-Joo
    • Korean Journal of Heritage: History & Science
    • /
    • v.49 no.4
    • /
    • pp.52-63
    • /
    • 2016
  • The Stupa of Buddhist Monk Soyo in Baegyangsa temple, Jangseong, was erected to pay a tribute to the achievement of the Buddhist monk Soyo, who worked for Baegyangsa temple as a chief monk, and is a bellshaped stupa with the detailed pattern of a Korean traditional buddhist bell. It is composed of pinkish-grey sandstone and the body of the stupa was damaged by longitudinal cracks on the front and back areas and the exfoliation caused break-out in the most part of the sculpture on the left and right areas. According to the ultrasonic test and infrared thermography analysis for physical deterioration diagnosis, most weathering aspects appeared on the body of the stupa and some exfoliated part that could not be seen with the naked eye was detected 6.1% and 5.9% on the left and right side respectively. Hyperspectral imaging analysis was also carried out to assess biological deterioration. According to the result, the surface of the stupa was covered 71.8 ~ 79.9% with vegetation like algae, lichen and moss. NDVI(Normalized Difference Vegetation Index) was higher relatively on the bottom part near the ground, right and back areas of the stupa. Therefore conservation treatment for the exfoliated part and bio-deterioration is necessary and the environment condition needs to be fixed to prevent extra damages on the stupa.

COMPARISON OF LOS DOPPLER VELOCITIES AND NON-THERMAL LINE WIDTHS IN THE OFF-LIMB SOLAR CORONA MEASURED SIMULTANEOUSLY BY COMP AND HINODE/EIS

  • Lee, Jae-Ok;Lee, Kyoung-Sun;Seough, Jungjoon;Cho, Kyung-Suk
    • Journal of The Korean Astronomical Society
    • /
    • v.54 no.2
    • /
    • pp.49-60
    • /
    • 2021
  • Observations of line of sight (LOS) Doppler velocity and non-thermal line width in the off-limb solar corona are often used for investigating the Alfvén wave signatures in the corona. In this study, we compare LOS Doppler velocities and non-thermal line widths obtained simultaneously from two different instruments, Coronal Multichannel Polarimeter (CoMP) and Hinode/EUV Imaging Spectrometer (EIS), on various off-limb coronal regions: flaring and quiescent active regions, equatorial quiet region, and polar prominence and plume regions observed in 2012-2014. CoMP provides the polarization at the Fe xiii 10747 Å coronal forbidden lines which allows their spectral line intensity, LOS Doppler velocity, and line width to be measured with a low spectral resolution of 1.2 Å in 2-D off limb corona between 1.05 and 1.40 RSun, while Hinode/EIS gives us the EUV spectral information with a high spectral resolution (0.025 Å) in a limited field of view raster scan. In order to compare them, we make pseudo raster scan CoMP maps using information of each EIS scan slit time and position. We compare the CoMP and EIS spectroscopic maps by visual inspection, and examine their pixel to pixel correlations and percentages of pixel numbers satisfying the condition that the differences between CoMP and EIS spectroscopic quantities are within the EIS measurement accuracy: ±3 km s-1 for LOS Doppler velocity and ±9 km s-1 for non-thermal width. The main results are summarized as follows. By comparing CoMP and EIS Doppler velocity distributions, we find that they are consistent with each other overall in the active regions and equatorial quiet region (0.25 ≤ CC ≤ 0.7), while they are partially similar to each other in the overlying loops of prominences and near the bottom of the polar plume (0.02 ≤ CC ≤ 0.18). CoMP Doppler velocities are consistent with the EIS ones within the EIS measurement accuracy in most regions (≥ 87% of pixels) except for the polar region (45% of pixels). We find that CoMP and EIS non-thermal width distributions are similar overall in the active regions (0.06 ≤ CC ≤ 0.61), while they seem to be different in the others (-0.1 ≤ CC ≤ 0.00). CoMP non-thermal widths are similar to EIS ones within the EIS measurement accuracy in a quiescent active region (79% of pixels), while they do not match in the other regions (≤ 61% of pixels); the CoMP observations tend to underestimate the widths by about 20% to 40% compared to the EIS ones. Our results demonstrate that CoMP observations can provide reliable 2-D LOS Doppler velocity distributions on active regions and might provide their non-thermal width distributions.

A Real-time Correction of the Underestimation Noise for GK2A Daily NDVI (GK2A 일단위 NDVI의 과소추정 노이즈 실시간 보정)

  • Lee, Soo-Jin;Youn, Youjeong;Sohn, Eunha;Kim, Mija;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1301-1314
    • /
    • 2022
  • Normalized Difference Vegetation Index (NDVI) is utilized as an indicator to represent the vegetation condition on the land surface in various applications such as land cover, crop yield, agricultural drought, soil moisture, and forest disaster. However, satellite optical sensors for visible and infrared rays cannot see through the clouds, so the NDVI of the cloud pixel is not a valid value for the land surface. This study proposed a real-time correction of the underestimation noise for GEO-KOMPSAT-2A (GK2A) daily NDVI and made sure its feasibility through the quantitative comparisons with Moderate Resolution Imaging Spectroradiometer (MODIS) NDVI and the qualitative interpretation of time-series changes. The underestimation noise was effectively corrected by the procedures such as the time-series correction considering vegetation phenology, the outlier removal using long-term climatology, and the gap filling using rigorous statistical methods. The correlation with MODIS NDVI was higher, and the difference was lower, showing a 32.7% improvement compared to the original NDVI product. The proposed method has an extensibility for use in other satellite products with some modification.

High-Power Continuous-Wave Laser-Induced Damage to Complementary Metal-Oxide Semiconductor Image Sensor (고출력 CW 레이저에 의한 CMOS 영상 센서의 손상 분석)

  • Kim, Jin-Gyum;Choi, Sungho;Yoon, Sunghee;Jhang, Kyung-Young;Shin, Wan-Soon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.1
    • /
    • pp.105-109
    • /
    • 2015
  • This paper presents the results of an experimental analysis of the high-power laser (HPL)-induced damage to a complementary metal-oxide semiconductor (CMOS) image sensor. Although the laser-induced damages to metallic materials have been sufficiently investigated, the damages to electric-optic imaging systems, which are very sensitive to HPLs, have not been studied in detail. In this study, we experimentally analyzed the HPL-induced damages to a CMOS image sensor. A near-infrared continuous-wave (CW) fiber laser was used as the laser source. The influences of the irradiance and irradiation time on the permanent damages to a CMOS image sensor, such as the color error and breakdown, were investigated. The experimental results showed that the color error occurred first, and then the breakdown occurred with an increase in the irradiance and irradiation time. In particular, these damages were more affected by the irradiance than the irradiation time.

Multiple Outbursts of a Short-Periodic Comet 15P/Finlay

  • Ishiguro, Masateru;Kuroda, Daisuke;Kim, Yoonyoung;Kwon, Yuna;Hanayama, Hidekazu;Miyaji, Takeshi;Honda, Satoshi;Takahashi, Jun;Watanabe, Jun-Ichi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.61.2-61.2
    • /
    • 2015
  • 15P/Finlay is one of the Jupiter-Family Comets that has long been known since the late 19 century. The comet maintains the perihelion around 1.0 AU over a century, without showing any prominent activities (i.e. fragmentation or eruption) since the discovery. According to reports in unpublished observations, the comet exhibited an outburst in the middle of 2014 December. We conducted a imaging observation of 15P/Finlay just after the report, from 2014 December 23 to 2015 February 18 using three telescopes (the Okayama Astrophysical Observatory 50-cm telescope, the Ishigakijima Astronomical Observatory 105-cm telescope, and the Nishi-Harima Astronomical Observatory 2-m telescope), which constitute a portion of the OISTER (an inter-university observation network in the optical and infrared wavelengths). As a result of the frequent observations, we witnesses the second outburst around UT 2015 January 16. Such cometary outbursts draw the attention to researchers on ground that they could offer insight into the internal structure of comets, following a historical outburst occurred at 17P/Holmes on 2007 October 23. Although cometary outbursts have been often reported mostly in unpublished observations or unreviewed reports, it should be emphasized that there are not a sufficient number of astrophysical research which characterizes the physical properties by observing the aftermaths. This presentation provides a new observational result of 15P/Finlay outburst. Based on the morphological development of the dust cloud as well as the near-nuclear magnitude, we will derive the kinetic energy of the outburst. Finally we plan to compare the results of 15P/Finlay with those of analogical events at 17P/Holmes and P/2010 V1 (Ikeya-Murakami).

  • PDF