• Title/Summary/Keyword: Infrared analysis

Search Result 2,250, Processing Time 0.033 seconds

Partial Least Squares-discriminant Analysis for the Prediction of Hemodynamic Changes Using Near Infrared Spectroscopy

  • Seo, Youngwook;Lee, Seungduk;Koh, Dalkwon;Kim, Beop-Min
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.57-62
    • /
    • 2012
  • Using continuous wave near-infrared spectroscopy, we measured time-resolved concentration changes of oxy-hemoglobin and deoxy-hemoglobin from the primary motor cortex following finger tapping tasks. These data were processed using partial least squares-discriminant analysis (PLS-DA) to develop a prediction model for a brain-computer interface. The tasks were composed of a series of finger tapping for 15 sec and relaxation for 45 sec. The location of the motor cortex was confirmed by the anti-phasic behavior of the oxy- and deoxy-hemoglobin changes. The results were compared with those obtained using the hidden Markov model (HMM) which has been known to produce the best prediction model. Our data imply that PLS-DA makes better judgments in determining the onset of the events than HMM.

Numerical Analysis of Nozzle Plume Flow-Fields at Various Flight Conditions for Infrared Signature Investigation (IR 신호 분석을 위한 비행 조건에 따른 노즐 열유동장 해석)

  • Chun, S.H.;Yang, Y.R.;Moon, H.;Kim, J.Y.;Myong, R.S.;Cho, T.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.601-604
    • /
    • 2011
  • Plume flow-fields of aircraft nozzles are numerically investigated at various flight conditions for infrared signature analysis. A mission profile of subsonic unmanned combat aerial vehicle is considered for the requirement of each mission, associated engine and nozzles are selected through a performance analysis. Numerical results of nozzle plume flow-fields using a CFD code are analyzed in terms of thrust, maximum temperature. It is shown that maximum temperature increase for lower altitude and higher Mach number.

  • PDF

Quantitative Analysis of Taurine Using Near Infrared Spectrometry (NIRS) (근적외선 분광분석법을 이용한 타우린의 정량 분석)

  • Cho, Chang-Hee;Kim, Hyo-Jin;Meang, Dae-Young;Seo, Sang-Hun;Cho, Jung-Hwan
    • YAKHAK HOEJI
    • /
    • v.42 no.6
    • /
    • pp.545-551
    • /
    • 1998
  • Near Infrared transmittance Spectroscopy (NIRS) was used to evaluate and quantify the pharmaceutical active compounds. In the paper, taurine (2-Aminoethanesulfonic acid) was quantitatively analyzed in commercial pharmaceutical preparations. For calibration a central composite factorial design was used to determine concentrations of ingredients in reference samples. For the quantitative analysis of taurine, the most suitable data analysis method includes the calculation of second derivatives and a partial least squares regression (PLSR) model. By NIR spectrometry, combined with PLSR, the taurine concentration was successfully predicted with a relative standard error of prediction (SEP) lower than 1.04%.

  • PDF

Analysis of the Infrared Absorption Spectrums of Magnesite (마그네사이트의 적외선 흡수 스펙트럼 해석)

  • 오기동
    • Journal of the Korean Ceramic Society
    • /
    • v.14 no.4
    • /
    • pp.226-229
    • /
    • 1977
  • The infrared absorption spectrum of Synthesized magnesite is shown in the wve number region 2510 and 745cm-1. By using Wilson's GF matrices the force constants' of the Urey-Bradley force field were deterined from the infrared absorption frequencies. For magnesite the stretching force constant K=5.41, the bending force constant H=0.46, the repulsive force constant F=1.97, and the force constant for the out-of-plane vibration fθ=0.65md/Å. For calcite they are K=5.51, H=0.38, F=1.88 and fθ=0.64md/Å.

  • PDF

Analysis of the error signals for infrared reticle seekers in multiple targets (다중 표적에 대한 적외선 레티클 탐색기의 오차 신호 분석)

  • 한성현;홍현기;최종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1438-1446
    • /
    • 1996
  • Infrared seekers using reticles with a single detector have been widely used due to small size and low cost. However, the analysis of the error signals and the performance in multiple targets are performed either simplistically or not at all. In this paper, we present detector signals and processing results using image and signal processing techniques, especially performance analysis in multiple targets. The simulation results are essential to make the advanced signal processing part of retical seekers which can deal with various engagement scenarios.

  • PDF

Rapid discrimination of commercial strawberry cultivars using Fourier transform infrared spectroscopy data combined by multivariate analysis

  • Kim, Suk Weon;Min, Sung Ran;Kim, Jonghyun;Park, Sang Kyu;Kim, Tae Il;Liu, Jang R.
    • Plant Biotechnology Reports
    • /
    • v.3 no.1
    • /
    • pp.87-93
    • /
    • 2009
  • To determine whether pattern recognition based on metabolite fingerprinting for whole cell extracts can be used to discriminate cultivars metabolically, leaves and fruits of five commercial strawberry cultivars were subjected to Fourier transform infrared (FT-IR) spectroscopy. FT-IR spectral data from leaves were analyzed by principal component analysis (PCA) and Fisher's linear discriminant function analysis. The dendrogram based on hierarchical clustering analysis of these spectral data separated the five commercial cultivars into two major groups with originality. The first group consisted of Korean cultivars including 'Maehyang', 'Seolhyang', and 'Gumhyang', whereas in the second group, 'Ryukbo' clustered with 'Janghee', both Japanese cultivars. The results from analysis of fruits were the same as of leaves. We therefore conclude that the hierarchical dendrogram based on PCA of FT-IR data from leaves represents the most probable chemotaxonomical relationship between cultivars, enabling discrimination of cultivars in a rapid and simple manner.

Analysis of Flow and Infrared Signature Characteristics according to UCAV Nozzle Shape (무인전투기 배기구 형상에 따른 유동 및 적외선 신호 특성 분석)

  • Noh, Sooyoung;Bae, Ji-Yeul;Kim, Jihyuk;Nam, Juyeong;Jo, Hana;Cho, Hyung Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.5
    • /
    • pp.27-35
    • /
    • 2019
  • Stealth technology is a technique to avoid detection from detectors such as radar and infrared seekers. In particular, detection by infrared signature is more threatening because infrared missiles detect heat from the aircraft itself. Therefore, infrared stealth technology is essential for ensuring the survival of aircraft and unmanned combat aerial vehicles (UCAV). In this study, we analyzed aerodynamic and infrared stealth performance in relation to UCAV nozzle design. Based on simulation results, a double serpentine nozzle was effective in reducing the infrared signature because it could shield high-temperature components in the engine. In addition, we observed that the infrared signature was reduced at the turning position of the duct located at the rear part of the double serpentine nozzle.

Near Infrared Diffuse Reflectance Spectroscopy to Measure Pulmonary Edema

  • Larry Leonardi;David H.Burns;Luis Openheimer;Rene P.Michel
    • Near Infrared Analysis
    • /
    • v.2 no.1
    • /
    • pp.43-53
    • /
    • 2001
  • A non-invasive spectroscopic method is presented for the measurement of pulmonary edema. Both early diagnosis and quantitative edema estimates were investigated. The spectroscopic determination of pulmonary edema involved the acquisition of diffuse reflectance spectra in the near-infrared (NIR) region with change in water concentration - water is the main constituent of edema fluid. Pulmonary edema was induced into the excised perfused lungs of seven animals by elevating the hydrostatic pressure. Estimates of edema were ascertained from a partial least squares regression of the measured spectral response. Actual edema was determined from the change (increase) in total lung weight. Estimates in relative lung weight increases due to in vitro edema were made with the near infrared spectra. The results revealed that fluid accumulation produced spectral changes in the O-H and C-H absorptions as well as scattering changes in the spectra. Histology of the lung was used to verify the presence or absence of interstitial and alveolar edema. Results demonstrated that near infrared spectroscopy might provide a new tool for clinical assessment of pulmonary edema.

Microwave Dielectric Properties and Infrared ReflectivitySpectra of (Zr$_{0.8}$Sn$_{0.2}$)TiO$_4$ Ceramics ((Zr$_{0.8}$Sn$_{0.2}$)TiO$_4$ 세라믹스의 마이크로파 유전특성 및 Infrared Reflectivity Spectra of (Zr0.8Sn0.2)TiO4)

  • 윤기현;안일석;김우섭;김응수
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.9
    • /
    • pp.915-922
    • /
    • 1999
  • Microwave dielectric properties and far infrared reflectivity spectra of the (Zr0.8Sn0.2)TiO4 ceramics were inves-tigated with the various cooling rate. Dielectric constant was nearly same value while the unloaded Q value was largely affected by cooling rate. The Q.f of 42,140 at 7 GHz was obtained for the specimens with cooling rate of 1$^{\circ}C$/min. The effect of the cooling rate on the change of the ionic the electronic polarization and the intrinsic microwave loss of the specimens were investigated by the infrared reflectivity spectra from 50 to 4000cm-1 which were calculated by Kramers-Kroning analysis and the classical oscillator model. The relative tendency of microwave dielectric properties of the specimens calculated from the relfectivity data were in good agreement with the results by the post resonant method.

  • PDF