• Title/Summary/Keyword: Infrared Module

Search Result 152, Processing Time 0.028 seconds

Development of NDIR CO2 Gas Detector Using Thermopile Sensor (써모파일 센서를 이용한 NDIR CO2 가스검출기의 개발)

  • Cho, Si-Hyung;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.35-38
    • /
    • 2012
  • We present a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. Using this thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF

Study about the home network system implementation that used an ubiquitous sensor network (유비쿼터스 센서 네트워크을 이용한 홈네트워크 시스템 구현에 관한 연구)

  • Nam, Sang-Yep;Park, Chun-Myoung
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.479-480
    • /
    • 2007
  • It is study about implementation of the home network system that used an ubiquitous sensor network and an embedded system in this paper. PXA270 and CC2420 were used, and the home server of a wireless sensor home network system composed it. A wireless control system is composed of a gas valve, a DC motor, a lamp and a door rock. A wireless detection system is composed of a gas detection sensor, a movement detection sensor, an extension detection sensor The wireless detection system that was an environment sensing system was composed of temperature, humidity, mic, illuminance, a speed-up, infrared rays temperature sensing module, and modular, other RFID established an USB camera, and an ubiquitous home network was composed.

  • PDF

Prediction of the content of white clover and perennial ryegrass in fresh or dry mixtures made up from pure botanical samples, by near infrared spectroscopy

  • Blanco, Jose A.;Alomar, Daniel J.;Fuchslocher, Rita I.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1266-1266
    • /
    • 2001
  • Pasture composition, an important attribute determining sward condition and value, is normally assessed by hand separation, drying and measuring weight contribution of each species in the mixture. This is a tedious, time and labour consuming procedure. NIRS has demonstrated the potential for predicting botanical composition of swards, but most of the work has been carried out on dry samples. The aim of this work was to evaluate the feasibility of developing NIR models for predicting the white clover and ryegrass content in fresh or dry mixtures artificially prepared from pure samples of both species. Mixtures from pure stands of white clover(Trifolium repens) and perennial ryegrass (Lolium perenne) were prepared with different proportions (0 to 100%) of each species (fresh weight). A total of 55 samples were made (11 mixtures,5 cuts). Spectra (400 to 2500 nm) were taken from fresh chopped (rectangular cuvettes, transport sample module) samples, in a NIR Systems 6500 scanning monochromator controlled by the software NIRS 3 (Infrasoft International), which was also utilized for calibration development. Different math treatments (derivative order, subtraction gap and smooth segment) and a scatter correction treatment of the spectra (SNV and Detrend) were tested. Equations were developed by modified partial least squares. Prediction accuracy evaluated by cross-validation, showed that percentage of clover or ryegrass, as contribution in dry weight, can be successfully percentage of clover or ryegrass, as contribution in dry weight, can be successfully predicted either on fresh or dried samples, with equations developed by different math treatments. Best equations for fresh samples were developed including a first, second, or third derivative, whereas for dry samples best equations included a second or third derivative. Standard errors of ross validation were about 6% for fresh and 3.6% for dry samples, Coefficient of determination of cross validation (1-VR) were over 0.95 times the value of SECV for fresh samples and over 8 times the value of SECV for dry samples. Scatter correction (SNV and Detrend) in general improved prediction accuracy. It is concluded more precise on dried and ground samples, it can be used with an acceptable error level and less time and labour, on fresh samples.

  • PDF

NIS quality analysis of pre- and post-harvest sugarcane.

  • Johnson, Sarah E.;Berding, Nils
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1621-1621
    • /
    • 2001
  • The quality of sugarcane grown on the NE Australian tropical coast ($16^{\circ}$15'- $18^{\circ}$15' S Lat.) has declined markedly in the past seven years. This has been linked to dilution of mill-supply cane with increasing levels of non mature-stalk material consisting of leaves and sucker culms. The prime research objective was to examine the transition from the pre-harvest, in-field crop to harvested material sent for processing, in terms of quality and crop fraction proportions. A secondary objective was to quantify the effects of preharvest-season crop habit and culm condition on crop quality. Ten quadrat samples from each of 54 random crop sites (17 in 1999 and 37 in 2000), covering a wide range of variables (cultivar, crop class, and edaphic, topographic, climatic, and temporal factors) were collected immediately before harvest. Samples were partitioned into four fractions:- sound and unsound mature stalks (culms), sucker culms, and extraneous matter (leaves). Material harvested from each site was sampled and partitioned into four fractions:- sound and unsound billets (culm pieces), culm-spindle pieces, and leaf. In 2000, before harvest, 14 additional sites were sampled monthly, on three occasions, from March - June. Erect and non-erect culms were divided into sound and unsound classes. All samples were disintegrated and presented to a remote reflectance module of a scanning spectrophotometer using the BSES large cassette module. Near infra-red spectroscopic (NIS) analyses were developed for the rapid determination of quality components (Brix, commercial cane sugar (CCS), fibre, moisture, and polariscope reading). Calibrations for three material groups (culm (n = 639), non-culm (n = 496), and combined) were developed for all components using the 1999 data set. Two sub-sets (n = 178, and 190) of about 10% of the preharvest-season and harvest populations scanned in 2000 also were subjected to full routine laboratory analyses. The 1999 combined calibrations were excellent, but the culm calibrations produced consistently lower standard errors. Non-culm calibrations were marginally better than the combined for only CCS and pol. reading. Analysis of the 2000 culm data with calibrations using all 1999 and 2000 culm data resulted in better predictions relative to the 1999 culm calibrations. This also was true for the combined calibrations. Assessment of quality components in pre- and post-harvest sugarcane using NIS calibrations was more cost effective than using routine laboratory techniques. Outcomes from this NIS-facilitated research will have important economic consequences for the Australian sugarcane industry. Potential CCS present in mature culms is being discounted by dilution with leaves and sucker culms, threatening farm viability. The results question the efficacy of current harvesting technology. The CCS of harvested cane is improved only marginally over that of the in-field crop. Current harvesting technology requires either supplementary, innovative pre-mill processing or a design revolution to improve mill-supply cane quality, and therefore whole of industry economics. NIS-facilitated analyses, before the harvest season, highlighted the benefits of growing erect, sound crops. Loss of CCS then, can be minimized only by a combination of crop improvement and agronomic solutions, applied as part of sound on-farm management.

  • PDF

A Study on the Real-Time Oil-Spill Monitoring Technology (실시간 기름유출 모니터링 기술에 관한 연구)

  • Yeom, Woo-jung;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.472-477
    • /
    • 2017
  • Oil spills cause a lot of damage to the environment. Oil destroys the water environment and ecosystem in a very short period of time once they are contaminated by it, it takes a lot of time to recover from the contamination and the cleaning process is very difficult. Therefore, oil detectors are greatly needed as they can monitor any oil spills over the sea, rivers, and lakes. There are two kinds of technology available for detecting oil, viz. the contact and non-contact types. The former is based on the use of the conductivity, capacitance and microwaves, while the latter employs infrared, UV, laser, optic and radar technologies. As there are also various hurdles in the measuring of oil on water, such as the presence of waves, refraction of light, temperature and saltiness, it is imperative to select the right oil detector which is appropriate for the specific environment. In this study, a contact type oil detector is developed, which can be used in oil related industries, such as refineries, petrochemical companies, and power generation stations. The detector is made up of the sensor module, which floats on the water, and the controller which processes the signal coming from the sensor module and displays it. It is designed in such a way that the existence of oil is detected through the sensor and the change in the permittivity is observed to determine the volume and type of spilled oil.

An Implementation of Obesity Management System with Individually Adapted Complex Care (개인 맞춤형 통합 치료가 가능한 비만 관리 시스템 개발)

  • Noh, Si-Cheol;Kim, Ju-Young;Kim, Jin-Su;Kang, Sang-Sik;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.83-91
    • /
    • 2012
  • The obesity is a medical condition in which excess body fat has accumulated to the extent. It may have an adverse effect on health, leading to reduced life expectancy and increased health problems such as lifestyle disease, hypertension, and diabetes. Furthermore, it may cause the mental illness such as depression, bipolar disorder, anorexia, hyperphagia, and so on by shrinking psychologically. So, it is regarded as the serious worldwide social problem. Recently, although there are many general obesity care methods with various approaches, these can't be the radical obesity care because of the side effects such as surgery aftereffect, drug addiction, and so on. For these reasons, a methodical approach with a consideration of individual obesity pattern is strongly demanded. In this study, complex obesity care and management system which is overcome the weakness of non-surgical obesity treatment is proposed. And the individually adapted obesity treatment system with the far-infrared therapy module, oxygen therapy module, color therapy module, and microwave therapy module was developed. The complex obesity treatment system which is proposed in this study, could improve the efficiency of treatment by suggesting the various treatment protocols. And proposed system could be the foundation of the high quality obesity treatment system.

Study of a Brain Tumor and Blood Vessel Detection System Using Multiple Fluorescence Imaging by a Surgical Microscope (수술현미경에서의 다중형광영상을 이용한 뇌종양과 혈관영상 검출 시스템 연구)

  • Lee, Hyun Min;Kim, Hong Rae;Yoon, Woong Bae;Kim, Young Jae;Kim, Kwang Gi;Kim, Seok Ki;Yoo, Heon;Lee, Seung Hoon;Shin, Min Sun;Kwon, Ki Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • In this paper, we propose a microscope system for detecting both a tumor and blood vessels in brain tumor surgery as fluorescence images by using multiple light sources and a beam-splitter module. The proposed method displays fluorescent images of the tumor and blood vessels on the same display device and also provides accurate information about them to the operator. To acquire a fluorescence image, we utilized 5-ALA (5-aminolevulinic acid) for the tumor and ICG (Indocyanine green) for blood vessels, and we used a beam-splitter module combined with a microscope for simultaneous detection of both. The beam-splitter module showed the best performance at 600 nm for 5-ALA and above 800 nm for ICG. The beam-splitter is flexible to enable diverse objective setups and designed to mount a filter easily, so beam-splitter and filter can be changed as needed, and other fluorescent dyes besides 5-ALA and ICG are available. The fluorescent images of the tumor and the blood vessels can be displayed on the same monitor through the beam-splitter module with a CCD camera. For ICG, a CCD that can detect the near-infrared region is needed. This system provides the acquired fluorescent image to an operator in real time, matching it to the original image through a similarity transform.

Soil Profile Measurement of Carbon Contents using a Probe-type VIS-NIR Spectrophotometer (프로브형 가시광-근적외선 센서를 이용한 토양의 탄소량 측정)

  • Kweon, Gi-Young;Lund, Eric;Maxton, Chase;Drummond, Paul;Jensen, Kyle
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.382-389
    • /
    • 2009
  • An in-situ probe-based spectrophotometer has been developed. This system used two spectrometers to measure soil reflectance spectra from 450 nm to 2200 nm. It collects soil electrical conductivity (EC) and insertion force measurements in addition to the optical data. Six fields in Kansas were mapped with the VIS-NIR (visible-near infrared) probe module and sampled for calibration and validation. Results showed that VIS-NIR correlated well with carbon in all six fields, with RPD (the ratio of standard deviation to root mean square error of prediction) of 1.8 or better, RMSE of 0.14 to 0.22%, and $R^2$ of 0.69 to 0.89. From the investigation of carbon variability within the soil profile and by tillage practice, the 0-5 cm depth in a no-till field contained significantly higher levels of carbon than any other locations. Using the selected calibration model with the soil NIR probe data, a soil profile map of estimated carbon was produced, and it was found that estimated carbon values are highly correlated to the lab values. The array of sensors (VIS-NIR, electrical conductivity, insertion force) used in the probe allowed estimating bulk density, and three of the six fields were satisfactory. The VIS-NIR probe also showed the obtained spectra data were well correlated with nitrogen for all fields with RPD scores of 1.84 or better and coefficient of determination ($R^2$) of 0.7 or higher.

Compositional analysis by NIRS diode array instrumentation on forage harvesters

  • Andreashaeusler, Michael Rode;Christian, Paul
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1619-1619
    • /
    • 2001
  • Ourwork aims to assess the content of dry matter, protein, cell wall parameters and water soluble carbohydrates in forages without having to handle samples, transport them to a laboratory, dry, grind and chemically analyze them. for this purpose, the concept of fresh forage analysis under field conditions by means of compact integrated NIRS InGaAs-diode array instruments on small plot harvesters is being evaluated for plant breeding trials. This work was performed with the world first commercial experimental forage plot harvester equipped with a NIRS module for the collection, compression, and scanning of forage samples (including automatic referencing and dark current measure ments). It was used for harvesting and analyzing a number of typical forage grass and forage legume plot trials. After NIRS measurements in the field each sample was again analyzed in the laboratory by means of a conventional grating spectrometer equipped with Si-and PbS-detectors. Conventional laboratory analysis of the samples was restricted to dry matter (DM) content by means of oven drying at 105. Routine chemometric procedures were then employed to assess the comparative accuracy and precision of the DM assessments in the spectral range between 950 and 1650nm by the NIRS diode array as well as by the conventional NIRS scanning instrument. The results of this study confirmed that the type of NIRS diode array instrument employed here functioned well even in rugged field operations. further refinements proved to be necessary for optimizing the automatic filling of the sample compartment to adjust for the wide variation in forage material under conditions of extremely low or high harvest yields. The error achieved in calibrating the apparatus for forages of typical DM content proved to be satisfactory (SECV < 1.0). Possibly as a consequence of higher sampling errors, its performance in atypical forages with elevated DM contents was less satisfactory. The error level obtained on the conventional grating NIR spectrometer was similar to that of the diode array instrument for both types of forage.

  • PDF

Walking and Stabilization Algorithm of Biped Robot on the Uneven Ground (이족보행로봇의 비평탄지형 보행 및 자세 안정화 알고리즘)

  • Kim Yong-Tae;Noh Su-Hee;Lee Hee-Jin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.1
    • /
    • pp.59-64
    • /
    • 2005
  • In the paper, we propose an intelligent walking algorithm of biped robot on the uneven ground and a posture stabilization algorithm against external forces. At first, the mechanics and the control system of biped robot that can walk on the uneven ground and stand external forces are designed. We propose obstacle hurdling, incline walking. and going-up stairs algorithm by using infrared sensors and FSR sensors. Also, posture stabilization algorithm against external forces is designed using FSR sensors. Infrared sensors ate used to detect the obstacles in the working environment and FSR sensors are used to obtain the ZMP of biped robot. The developed biped robot can be controlled by the remote control system using vision system and RF module. The experimental results show that the biped robot Performs obstacle avoidance, obstacle hurdling, walking on the inclined plane, and going up stairs using the proposed walking and stabilization algorithm.