• Title/Summary/Keyword: Information process

Search Result 27,868, Processing Time 0.07 seconds

Mobility and Safety Evaluation Methodology for the Locations of Hi-PASS Lanes Using a Microscopic Traffic Simulation Tool (미시교통시뮬레이션모형을 이용한 하이패스 차로 위치별 이동성 및 안전성 평가방법 연구)

  • Yun, Ilsoo;Han, Eum;Lee, Cheol-Ki;Rho, Jeong Hyun;Lee, Soojin;Kim, Sang Byum
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.1
    • /
    • pp.98-108
    • /
    • 2013
  • The number of Hi-Pass lanes became 793 lanes at 316 expressway tollgates in 2011 due to the increase in the Hi-Pass use. In spite of the increase in the number of Hi-Pass lanes, there have been increased potential risks in tollgates where vehicles using a Hi-Pass lane must weave with other vehicles using a TCS lane. Therefore, there is a need for study on the safety in tollgates. To this end, this study aims at developing a methodology to evaluate the performance measures of diverse location countermeasures of Hi-Pass lanes in an efficient and systematic way. This study measured the mobility, safety and the convenience of installation and operation of Hi-Pass lanes using a microscopic traffic simulation tool, the surrogate safety assessment model and survey. In addition, this study aggregated the above three performance indexes using weight factors estimated using the AHP technique. For the test site, Dongsuwon interchange was selected. After building the microscopic traffic simulation model for the test site, the location countermeasures of Hi-Pass lanes applicable to the test site were compared with each other in terms of the mobility, safety and installing and operating convenience. As a result, there has been no apparent difference in mobility index based on delays. However, the countermeasures where Hi-Pass lanes are located in inside lanes generally showed better safety performance based on the number of conflicts. In addition, countermeasures with neighboring Hi-Pass lanes were favorable in terms of the safety and the convenience of installation and operation. The methodology proposed in this study was found to be useful to support decision makings by providing critical and quantitative information regarding the mobility, safety and the convenience of installation and operation.

Directions for More Effective County Extension Committees (군 농촌지도위원회의 효율적 운영 방안)

  • Martens, Daniel C.;Kim, Sung-Soo
    • Journal of Agricultural Extension & Community Development
    • /
    • v.6 no.2
    • /
    • pp.75-84
    • /
    • 1999
  • Minnesota state law requires County Extension Committees (CECs). The County Board of Commissioners appoints committee members. Extension Educators are responsible for using CECs to assure the value of Extension work in the County. This paper will explore underlying values, principles and practices that can effect the utilization of CECs in ways that benefit the work of Extension and make the process a good experience for CEC members and Extension Educator. The paper is based primarily on readings in the Journal of Extension, interviews with two Extension Educator, and information provided by the University of Minnesota Extension Service for CEC members.

  • PDF

A basic research for evaluation of a Home Care Nursing Delivery System (가정간호 서비스 질 평가를 위한 도구개발연구)

  • Kim, Mo-Im;Cho, Won-Jung;Kim, Eui-Sook;Kim, Sung-Kyu;Chang, Soon-Bok;Ryu, Ho-Sihn
    • Journal of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.33-45
    • /
    • 1999
  • The purpose of this study was to develop a basic framework and criteria for evaluation of quality care provided to patients with the attributes of disease in the home care nursing field, and to provide measurement tools for home health care in the future. The study design was a developmental study for evaluation of hospital-based HCN(home care nursing) in Korea. The study process was as follows: a home care nursing study team of College of Nursing. Yonsei University reviewed the nursing records of 47 patients who were enrolled at Yonsei University Medical Center Home Care Center in March, 1995. Twenty-five patients were insured at that time, were selected from 47 patients receiving home care service for study feasibility with six disease groups; Caesarean Section (C/S), simple nephrectomy, Liver cirrhosis(LC), chronic obstructive pulmonary disease(COPD), Lung cancer or cerebrovascular accident(CVA). In this study, the following items were selected : First step : Preliminary study 1. Criteria and items were selected on the basis of related literature on each disease area. 2. Items were identified by home care nurses. 3. A physician in charge reviewed the criteria and content of selected items. 4. Items were revised through preliminary study offered to both HCN patients and discharged patients from the home care center. Second step : Pretest 1. To verify the content of the items, a pretest was conducted with 18 patients of which there were three patients in each of the six selected disease groups. Third step : Test of reliability and validity of tools 1. Using the collected data from 25 patients with either cis, Simple nephrectomy, LC, COPD, Lung cancer, or CVA. the final items were revised through a panel discussion among experts in medical care who were researchers, doctors, or nurses. 2. Reliability and validity of the completed tool were verified with both inpatients and HCN patients in each of field for researches. The study results are as follows: 1. Standard for discharge with HCN referral The referral standard for home care, which included criteria for discharge with HCN referral and criteria leaving the hospital were established. These were developed through content analysis from the results of an open-ended questionnaire to related doctors concerning characteristic for discharge with HCN referral for each of the disease groups. The final criteria was decided by discussion among the researchers. 2. Instrument for measurement of health statusPatient health status was measured pre and post home care by direct observation and interview with an open-ended questionnaire which consisted of 61 items based on Gorden's nursing diagnosis classification. These included seven items on health knowledge and health management, eight items on nutrition and metabolism, three items on elimination, five items on activity and exercise, seven items on perception and cognition, three items on sleep and rest, three items on self-perception, three items on role and interpersonal relations, five items on sexuality and reproduction, five items on coping and stress, four items on value and religion, three items on family. and three items on facilities and environment. 3. Instrument for measurement of self-care The instrument for self-care measurement was classified with scales according to the attributes of the disease. Each scale measured understanding level and practice level by a Yes or No scale. Understanding level was measured by interview but practice level was measured by both observation and interview. Items for self-care measurement included 14 for patients with a CVA, five for women who had a cis, ten for patients with lung cancer, 12 for patients with COPD, five for patients with a simple nephrectomy, and 11 for patients with LC. 4. Record for follow-up management This included (1) OPD visit sheet, (2) ER visit form, (3) complications problem form, (4) readmission sheet. and (5) visit note for others medical centers which included visit date, reason for visit, patient name, caregivers, sex, age, time and cost required for visit, and traffic expenses, that is, there were open-end items that investigated OPD visits, emergency room visits, the problem and solution of complications, readmissions and visits to other medical institution to measure health problems and expenditures during the follow up period. 5. Instrument to measure patients satisfaction The satisfaction measurement instrument by Reisseer(1975) was referred to for the development of a tool to measure patient home care satisfaction. The instrument was an open-ended questionnaire which consisted of 11 domains; treatment, nursing care, information, time consumption, accessibility, rapidity, treatment skill, service relevance, attitude, satisfaction factors, dissatisfaction factors, overall satisfaction about nursing care, and others. In conclusion, Five evaluation instruments were developed for home care nursing. These were (1)standard for discharge with HCN referral. (2)instrument for measurement of health status, (3)instrument for measurement of self-care. (4)record for follow-up management, and (5)instrument to measure patient satisfaction. Also, the five instruments can be used to evaluate the effectiveness of the service to assure quality. Further research is needed to increase the reliability and validity of instrument through a community-based HCN evaluation.

  • PDF

An Analysis of Nursing education Research in China : 1990-1998 (중국 간호교육관련 연구실태 분석)

  • Ko Il-Sun;Li Chun-Yu;Kim Jing-Ai
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.5 no.2
    • /
    • pp.177-190
    • /
    • 1999
  • This study has been conducted on the basis of the literature review of Nursing Education Research in China from 1990 through August 1998. Its purpose was to support the basic data of nursing education which is risen as major revolutionary of nursing in China and those for exchange of information between Korea-China nursing education. It is retrospective and descriptive research analyzing one hundred eighty articles published in The Journal of China Nursing. The results of the study were as follows. 1. Only 33.3% of the professors of Technical Nursing School who have played of major role of nursing education in China have carried out the study related to nursing education. Baccalaureate program professors have marked 22.2% of all studies, and diploma program professors have done 12.2% of all. Therefore, the professors of above the diploma program have done total 44.4%. It explains that the professors of baccalaureate and diploma programs have done more studies related to nursing education than those of Technical Nursing School. 2. In terms of the study design, most of the studies(38.8%) were case studies introducing the curriculum contents that were done at education institutions. And then, 28.5% were reviewing the articles, and 15.6% were descriptive studies. 3. In terms of the content of the study, 38.3% were relevant to education of Technical Nursing School, 15.0% were about baccalaureate education, and 10.4% is about diploma. 4. To analyze the specific contents of the studies ; a. In baccalaureate program, human resources (professor or teaching), course extension, lab, classes, teaching method, education philosophy, goal of education, evaluation method, and human resource development were included. b. In diploma program, teaching contents evaluation method, teaching method, and educational system were included c. In the technical school, there were qualification of professors , teaching method, evaluation method, opening the courses, teaching contents, goal of education and so on. d. Beyond these, there were practice guidance and appraisement, teaching method, and opening new courses which were not specially indicated as educational curriculum and score management as continuing education. What is above tell us that the study regarding development of university system has been progressed actively and widely. It has been for the effort of revolution which based on the China government force to reform of nursing education process during last 10 years. On the base of the result, we suggest the following questions and the alternatives. 1) Since most articles are case studies related to teaching methods and the others doesn't propose the research method. the study which is applied more exact research method is needed. 2) No study is regarding social change and health policy. Because University program, founded in 1983 is on the beginning point, the research about curriculum have to be taken as a top priority as well as to reflect social needs which are based on social changes and national health policy 3) Only one review article study tells nursing Human resource. To appear in large numbers in nursing manpower, avoid the present hospital nurses training system. Then, the study for manpower development which is able to accomplish in many fields has to be advanced. 4) Most studies did not have literature review processes, so it was impossible for researcher to know the past study tendency and there is no relation among studies as to same subject, the education about research method is needed.

  • PDF

A 10b 250MS/s $1.8mm^2$ 85mW 0.13um CMOS ADC Based on High-Accuracy Integrated Capacitors (높은 정확도를 가진 집적 커페시터 기반의 10비트 250MS/s $1.8mm^2$ 85mW 0.13un CMOS A/D 변환기)

  • Sa, Doo-Hwan;Choi, Hee-Cheol;Kim, Young-Lok;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.58-68
    • /
    • 2006
  • This work proposes a 10b 250MS/s $1.8mm^2$ 85mW 0.13um CMOS A/D Converter (ADC) for high-performance integrated systems such as next-generation DTV and WLAN simultaneously requiring low voltage, low power, and small area at high speed. The proposed 3-stage pipeline ADC minimizes chip area and power dissipation at the target resolution and sampling rate. The input SHA maintains 10b resolution with either gate-bootstrapped sampling switches or nominal CMOS sampling switches. The SHA and two MDACs based on a conventional 2-stage amplifier employ optimized trans-conductance ratios of two amplifier stages to achieve the required DC gain, bandwidth, and phase margin. The proposed signal insensitive 3-D fully symmetric capacitor layout reduces the device mismatch of two MDACs. The low-noise on-chip current and voltage references can choose optional off-chip voltage references. The prototype ADC is implemented in a 0.13um 1P8M CMOS process. The measured DNL and INL are within 0.24LSB and 0.35LSB while the ADC shows a maximum SNDR of 54dB and 48dB and a maximum SFDR of 67dB and 61dB at 200MS/s and 250MS/s, respectively. The ADC with an active die area of $1.8mm^2$ consumes 85mW at 250MS/s at a 1.2V supply.

Removal Effects of Bifenthrin and Metalaxyl Pesticides during Preparation and Fermentation of Baechu Kimchi (배추김치의 제조 및 발효과정 중 Bifenthrin과 Metalaxyl 농약의 제거 효과)

  • Jung, Ji-Kang;Park, So-Yeon;Kim, So-Hee;Kang, Jeong-Mi;Yang, Ji-Young;Kang, Soon-Ah;Chun, Hae-Kyoung;Park, Kun-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.9
    • /
    • pp.1258-1264
    • /
    • 2009
  • The removal effects of two commonly used pesticides of Bifenthrin and Metalaxyl during preparation and fermentation of kimchi were studied. The two pesticides were applied to Baechu cabbages intentionally for 20 seconds; the applied amounts of Bifenthrin and Metalaxyl were 3.02$\pm$0.09 ppm and 6.79$\pm$0.17 ppm, respectively. The Baechu cabbages were washed by water 3 times. Then the residual amounts of the two pesticides of Bifenthrin and Metalaxyl were measured and the removal rates were 21.7% and 16.1%, respectively. When Baechu cabbages were brined with 10% salt solution for 12 hours after the application of the two pesticides, the removal rates significantly increased to 98.7% and 60.8%, and when brined and washed 3 times by water, the removal rates even more increased to 99.7% and 73.4% respectively. Then we made kimchi and investigated the quantities of the residual pesticides during the fermentation at $4^{\circ}C$ for 3 weeks. The residual amounts of the pesticides in kimchi decreased in a time dependent manner, finally the amounts of the pesticides to 0.35$\pm$0.04 ppm and 0.48$\pm$0.06 ppm while the removal rates of the two pesticides were 57.8% and 81.0%, respectively. When the kimchi was fermented at $4^{\circ}C$ and $10^{\circ}C$ for 3 weeks, the removal rates of Bifenthrin were 57.8% and 72.2% and those of Metalaxyl were 81.0% and 85.6%, respectively. Consequently, it appeared that the residual pesticides can be removed during preparation, especially brining; the fermentation process of kimchi also removed the residual pesticides effectively, especially at higher temperature and long period.

Stand Yield Table and Commercial Timber Volume of Eucalyptus Pellita and Acacia Mangium Plantations in Indonesia (인도네시아 유칼립투스 및 아카시아 조림지의 임분수확표 및 이용가능 목재생산량 추정)

  • Son, Yeong-Mo;Kim, Hoon;Lee, Ho-Young;Kim, Cheol-Min;Kim, Cheol-Sang;Kim, Jae-Weon;Joo, Rin-Won;Lee, Kyeong-Hak
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • This study was conducted to develop a stand growth model and a stand yield table for Eucalyptus pellita and Acacia mangium plantations in Kalimantan, Indonesia. To develop a stand growth model, Weibull robability density function, a diameter class model, was applied in this study. In the development of stand growth model by site index and stand age, a hierarchy is generally required - estimation, recovery and prediction of the diameter class model. A number of grow equations were also involved in each process to estimate diameter, height, basal area, minimum or maximum diameter. To examine whether the grow equations are adequate for Eucalyptus pellita or Acacia mangium plantations, a fitness index was analyzed for each equation. The results showed that fitness indices were ranged from 65 to 89% for Eucalyptus pellita plantations and from 72 to 95% for Acacia mangium plantations. As being highly adequate for the plantations, a stand yield table was developed based on the resulted growth model, and applied to estimate the stand growth with midium site index for 10-year period. The highest annual stand growth of Eucalyptus pellita plantations was estimated to be 21.25 $m^3$/ha, while that of Acacia mangium plantations was 27.5 $m^3$/ha. In terms of annual stand growth, Acacia mangium plantations appeared to be more beneficial than Eucalyptus pellita plantations. Also, to estimate commercial timber volume available from the plantations, an assumption that a log would be cut by 2.7 m in length and the rest of the log would be cut by 1.5m was involved. The commercial timber volume available from Eucalyptus pellita plantations was 68.0 $m^3$/ha, 33% from the total stand volume, 203.2 $m^3$/ha. Also 96.7 $m^3$/ha of commercial timbers were available from Acacia mangium plantations, which was 42% from the 232.9 $m^3$/ha in total. Presenting a good information about the stand growth in Eucalyptus pellita and Acacia mangium plantations, this study might be useful for whom proceeds or considers an abroad plantation for merchantable timber production or carbon credit in tropical regions.

Biogeochemical Studies on Tidal Flats in the Kyunggi Bay: Introduction (경기만 부근 갯벌의 생지화학적 연구: 서문)

  • Cho, B.C.;Choi, J.K.;Lee, T.S.;An, S.;Hyun, J.H.
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Tidal flats have been regarded to carry out transformation and removal of land-derived organic matter, and this purifying capability of organic matter by tidal flats is one of very important reasons for their conservation. However, integral biogeochemical studies on production and decomposition of organic matter by benthic microbes in tidal flats have been absent in Korea, although the information is indispensable to quantification of the purifying capability. Our major goals in this multidisciplinary research were to understand major biogeochemical processes and rates mediated by diverse groups of microbes dominating material cycles in the tidal flats, and to assess the contribution of benthic microbes to removal of organic matter and nutrients in the tidal flats. Our study sites were Ganghwa and Incheon north-port tidal flats that had been regarded as naturally well reserved and organically polluted, respectively. Our research group measured over 3 years primary production, biomass and community structure of primary producers, abundance and production of bacteria, enzyme activities, distribution of protozoa and protozoan grazing rates, rates of denitrification and sulfate reduction, early sediment diagenesis, primary production and respiration based on oxygen microelectrode. We analyzed major features of each biogeochemical process and their interactions. The results are compiled in the following articles in this special issue: An (2005), Hwang and Cho (2005), Mok et at. (2005), Na and Lee (2005), Yang et at. (2005), and Yoo and Choi (2005).

High LO-RF Isolation W-band MIMIC Single-balanced Mixer (높은 LO-RF 격리 특성의 W-band MIMIC Single-balanced 믹서)

  • An Dan;Lee Bok-Hyung;Lim Byeong-Ok;Lee Mun-Kyo;Lee Sang-Jin;Jin Jin-Min;Go Du-Hyun;Kim Sung-Chan;Shin Dong-Hoon;Park Hyung-Moo;Park Hyim-Chang;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.6 s.336
    • /
    • pp.67-74
    • /
    • 2005
  • In this paper, high LO-RF isolation W-band MIMIC single-balanced mixer was designed and fabricated using a branch line coupler and a $\lambda$/4 transmission line. The simulation results of the designed 94 GHz balun show return loss of -27.9 dB, coupling of -4.26 dB, and thru of -3.77 dB at 94 GHz, respectively. The isolation and phase difference were 23.5 dB and $180.2^{\circ}$ at 94 GHz. The W-band MIMIC single-balanced mixer was designed using the 0.1 $\mu$m InGaAs/InAlAs/GaAs Metamorphic HEMT diode. The fabricated MHEMT was obtained the cut-off frequency(fT) of 189 GHz and the maximum oscillation frequency(fmax) of 334 GHz. The designed MIMIC single-balanced mixer was fabricated using 0.1 $\mu$m MHEMT MIMIC Process. From the measurement, the conversion loss of the single-balanced mixer was 23.1 dB at an LO power of 10 dBm. Pl dB(1 dB compression point) of input and output were 10 dBm and -13.9 dBm respectively. The LO-RF isolations of single-balanced mixer was obtained 45.5 dB at 94.19 GHz. We obtained in this study a higher LO-RF isolation compared to some other balanced mixers in millimeter-wave frequencies.

A 10b 200MS/s 75.6mW $0.76mm^2$ 65nm CMOS Pipeline ADC for HDTV Applications (HDTV 응용을 위한 10비트 200MS/s 75.6mW $0.76mm^2$ 65nm CMOS 파이프라인 A/D 변환기)

  • Park, Beom-Soo;Kim, Young-Ju;Park, Seung-Jae;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.60-68
    • /
    • 2009
  • This work proposes a 10b 200MS/s 65nm CMOS ADC for high-definition video systems such as HDTV requiring high resolution and fast operating speed simultaneously. The proposed ADC employs a four-step pipeline architecture to minimize power consumption and chip area. The input SHA based on four capacitors reduces the output signal range from $1.4V_{p-p}$ to $1.0V_{p-p}$ considering high input signal levels at a low supply voltage of 1.2V. The proposed three-stage amplifiers in the input SHA and MDAC1 overcome the low output resistance problem as commonly observed in a 65nm CMOS process. The proposed multipath frequency-compensation technique enables the conventional RNMC based three-stage amplifiers to achieve a stable operation at a high sampling rate of 200MS/s. The conventional switched-bias power-reduction technique in the sub-ranging flash ADCs further reduces power consumption while the reference generator integrated on chip with optional off-chip reference voltages allows versatile system a locations. The prototype ADC in a 65nm CMOS technology demonstrates a measured DNL and INL within 0.19LSB and 0.61LSB, respectively. The ADC shows a maximum SNDR of 54.BdB and 52.4dB and a maximum SFDR of 72.9dB and 64.8dB at 150MS/S and 200MS/s, respectively. The proposed ADC occupies an active die area of $0.76mm^2$ and consumes 75.6mW at a 1.2V supply voltage.