• Title/Summary/Keyword: Inflammation and foreign body reaction

Search Result 19, Processing Time 0.024 seconds

Histopathological Changes of Subcutaneous Exposure to Glass Fibers in Rats (흰쥐에서 유리섬유의 피하삽입에 의한 경시적 병리조직학적 변화)

  • Lee, Min-Jae;Cho, Soo-Hun;Jang, Ja-June
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.69-76
    • /
    • 1997
  • To exanime in vivo tissue reactions of glass fibers, we injected glass fibers to rats subcutaneously. We made fibers of average dimensions of approximately $2{\mu}m$ in diameter and $60{\mu}m$ in length. After instilation of glass fiber we sacrificed rats sequentially at 1, 3 and 6 months. At 1 month after injection of glass fibers, the exposure area turned to yellow color and formed well-demarcated round mass. The average size of the mass was $1\times0.3cm$. Grossly detectable mass was decreased in size at 6 months compared to 1 or 3 months. Microscopically, strong foreign body reaction to glass fibers, inflammation and fibrosis were observed until 6 months. Foreign body reaction was increased up to 3 months, but it was decreased after 6 months. In scanning electron microscope, there was many bundles of glass fibers around the inflammation area, but the size of glass fibers were gradually reduced from 1 month to 6 months. These results suggest that subcutaneous exposure of glass fiber can provoke strong tissue reaction including foreign body granulomas, inflammation and fibrosis. But glass fiber itself did not produce any neoplastic changes.

  • PDF

Wound healing effect of regenerated oxidized cellulose versus fibrin sealant patch: An in vivo study

  • Yoon, Hyun Sik;Na, Young Cheon;Choi, Keum Ha;Huh, Woo Hoe;Kim, Ji Min
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.5
    • /
    • pp.289-296
    • /
    • 2019
  • Background: Topical hemostatic agents are used when ligation, electrocauterization, or other conventional hemostatic methods are impractical. Because a hemostatic agent is a foreign body, it can cause foreign body reactions, inflammation, and infections that can interfere with the wound healing process. Therefore, we should select hemostatic agents after considering their effects on wound healing. Here, we compared the effects of hemostatic agents on wound healing in a rectus abdominis muscle defect in rats. Methods: Twelve Sprague Dawley rats were subjected to creation of a $6{\times}6mm$ defect in the rectus abdominis muscle and divided into four groups: control group; group A, Tachosil fibrin sealant patch; group B, Surgicel Fibrillar oxidized regenerated cellulose; and group C, Surgicel Snow oxidized regenerated cellulose. For the histologic analysis, biopsies were performed on the 3rd, 7th, and 27th days. Results: The foreign body reaction was the weakest in group A and most significant in group C. The inflammatory cell infiltration was the weakest in group A and similar in groups B and C. Muscle regeneration differed among periods. The rats in group A were the most active initially, while those in group C showed prolonged activity. Conclusion: Tachosil and Surgicel administration increased inflammation via foreign body reactions, but the overall wound healing process was not significantly affected. The increased inflammation in the Surgicel groups was due to a low pH. We recommend using Tachosil, because it results in less intense foreign body reactions than Surgicel and faster wound healing due to the fibrin action.

MRI Findings of Intramuscular Foreign Body Injection: A Case Report (근육 내 이물질 주사의 자기 공명 영상 소견: 증례 보고)

  • So, Seong Yong;Kim, Hyun-Joo;Choi, Deuk Lin;Hong, Seong Sook;Chang, Yun-Woo;Park, Sung Tae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.59-62
    • /
    • 2013
  • There are various types of foreign body reactions, such as inflammation, edema, fluid collection, hematoma, infection, abscess and granulomas. There are various imaging findings according to types of foreign bodies and depending on the lapse of time. Therefore, correct diagnosis of a foreign body reaction is difficult and easily confused with soft tissue neoplasm. The MRI is ideal for the detection of foreign bodies regardless of radiolucency or acoustic impedance. It is especially very useful in the evaluation of the surrounding tissue reaction. The authors report a case of a 26-year-old female patient with both forearm swelling due to self-injection of a mixture of powdered tablets and saline. The lesion shows numerous internal T1 and T2 dark signal intensity micro-spots with surrounding fluid collection, which are diagnosed as foreign bodies with surrounding inflammatory changes during an operation.

Silicone breast implant modification review: overcoming capsular contracture

  • Shin, Byung Ho;Kim, Byung Hwi;Kim, Sujin;Lee, Kangwon;Choy, Young Bin;Heo, Chan Yeong
    • Biomaterials Research
    • /
    • v.22 no.4
    • /
    • pp.319-327
    • /
    • 2018
  • Background: Silicone implants are biomaterials that are frequently used in the medical industry due to their physiological inertness and low toxicity. However, capsular contracture remains a concern in long-term transplantation. To date, several studies have been conducted to overcome this problem. This review summarizes and explores these trends. Main body: First, we examined the overall foreign body response from initial inflammation to fibrosis capsule formation in detail and introduced various studies to overcome capsular contracture. Secondly, we introduced that the main research approaches are to inhibit fibrosis with anti-inflammatory drugs or antibiotics, to control the topography of the surface of silicone implants, and to administer plasma treatment. Each study examined aspects of the various mechanisms by which capsular contracture could occur, and addressed the effects of inhibiting fibrosis. Conclusion: This review introduces various silicone surface modification methods to date and examines their limitations. This review will help identify new directions in inhibiting the fibrosis of silicone implants.

Foreign Body Reaction after Implantation of a Device for Intervertebral Assisted Motion

  • Seo, Jun-Yeong;Ha, Kee-Yong;Kim, Young-Hoon;Ahn, Joo-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.647-649
    • /
    • 2016
  • The device for intervertebral assisted motion (DIAM) is a dynamic implant that consists of a silicone bumper enveloped by a polyethylene terephthalate (PET) fiber sack. Silicone and PET were used because of their biological inertness, but repetitive motion of the spine can cause wear on the implant nonetheless. The purpose of this study is to report a case of foreign body reaction (FBR) against a DIAM. A 72-year-old female patient presented with lower back pain and both legs radiating pain. She had undergone DIAM implantation at L4-5 for spinal stenosis 5 years previously. The intervertebral disc space of L4-5, where the DIAM was inserted, had collapsed and degenerative scoliosis had developed due to left-side collapse. MRI showed L3-4 thecal sac compression and left L4-5 foraminal stenosis. The patient underwent removal of the DIAM and instrumented fusion from L3 to L5. During surgery, fluid and granulation tissue were evident around the DIAM. Histopathology showed scattered wear debris from the DIAM causing chronic inflammation due to the resulting FBR. A FBR due to wear debris of a DIAM can induce a hypersensitivity reaction and bone resorption around the implant, causing it to loosen.

Various Methods of Reconstruction in Nasal Defect (코 결손 부위에 따른 다양한 재건)

  • Kim, Seok Kwun;Yang, Jin Il;Kwon, Yong Seok;Lee, Keun Cheol
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2010
  • Purpose: Nasal defect can be caused by excision of tumor, trauma, inflammation from foreign body reaction. Nose is located in the middle of face and protruded, reconstruction should be done in harmony with size, shape, color, and textures. We report various methods of nasal reconstruction using local flaps. Methods: From March 1998 to July 2008, 36 patients were operated to reconstruct the nasal defects. Causes of the nasal defects were tumor (18 cases), trauma (11 cases), inflammation from foreign body reaction (5 cases) and congenital malformation (2 cases). The sites of the defects were ala (22 cases), nasal tip (8 cases) and dorsum (6 cases). The thickness of the defects was skin only (5 cases), dermis and cartilagenous layer (7 cases) and full-thickness (24 cases). According to the sites and thickness of the defects, various local flaps were used. Most of alar defects were covered by nasolabial flaps or bilobed flaps and the majority of dorsal and tip defects were covered by paramedian forehead flaps. Small defects below $0.25 cm^2$ were covered with composite graft or full-thickness skin graft. Results: The follow-up period was 14 months. Partial flap necrosis was observed in a case, and one case of infection was reported, it was improved by wound revision and antibiotics. Nasal reconstruction with various local flaps could provide satisfactory results in terms of color and texture match. Conclusion: The important factors of nasal reconstruction are the shape of reconstructed nose, color, and texture. Nasolabial flap is appropriate method for alar or columellar reconstruction and nasolabial island flap is suitable for tip defect. The defect located lateral wall could be reconstructed with bilobed flap for natural color and texture. Skin graft should be considered when the defect could not afford to be covered by adjacent local flap. And entire nasal defect or large defect could be reconstructed by paramedian forehead flap.

A CLINICAL STUDY OF BIODEGRADABLE PLATES AND SCREWS IN ORAL AND MAXILLOFACIAL SURGERY (구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구)

  • Kim, Il-Kyu;Park, Seung-Hoon;Jang, Keum-Soo;Yang, Jung-Eun;Jang, Jae-Won;Sasikala, Balaraman
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.451-458
    • /
    • 2009
  • Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.

TISSUE HEALING RESPONSE OF INCISED WOUND SUTURED BY STAPLES AND VARIOUS SUTURE MATERIALS (Staple과 수종의 봉합물의 봉합부위 창상치유 조직반응)

  • Suh, Min-Jung;Lee, Jae-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.3
    • /
    • pp.500-514
    • /
    • 1996
  • The purpose of this study was to observe the tissue response in applying staples and various suture materials to both scalp and buccal mucosa in rabbits. 18 rabbits were divided into 6 groups. The incised wounds of both scalp and buccal mucosa were sutured with staples, polyglactin 910, chromic catgut, mer silk and nylon. The experimental animals were sacrificed after 1, 3, 5, 7, 10, 14 days posto peratively 3 animals at one time. The tissue was stained with Hematoxylin and eosin, and Masson's Trichrom. In light microscopic examinations, the sutured sites were examined histologi cally according to 6 degrees about inflammation and collagen deposit. The results were obtained as follows, 1. The chromic catgut, an absorbable suture material, was absorbed by 7 days, whereas polyglactin 910 and mersilk began to get absorbed after 7 days. 2. Mersilk manifested a broad range of inflammation in the scalp, and both staple and nylon showed a severe inflammatory reaction in the buccal mucosa. 3. With polyglactin 910, both tissue samples showed only minor foreign body reaction, however in the scalp, the process of fibrosis took place compara tively slowly, whereas in the buccal mucosa, it occurred promptly and manifested active fibrosis by 7 days. 4. Mersilk showed widespread a matrix formation in both scalp and buccal mucosa, and showed the most severe inflammatory reaction by 3 days, which did not seem to decrease even after 7 days. 5. Both staple and nylon showed relatively a severe inflammatory reaction, however fibrosis took place rather promptly compared to the other groups. 6. Generally, in the buccal mucosa fibrosis occurred more promptly than in the scalp in both control and experimental groups. 7. Retention of the suture material and stability of the knot were the best with the staple, and better stability was manifested by the multi-stranded poly glactin 910 and mersilk than singlestranded chromic catgut and nylon. From above results, in the buccal mucosa absorbable suture materials especially polyglactin 910 showed better response in the aspect of inflammatory reaction, while in the scalp monofilament suture materials such as staple and nylon manifested a early fibrosis and collagen formation.

  • PDF

Soft Tissue Response of Rabbit Larynx to Implanted Foley Catheter for Short Duration (토끼 후두내 삽입한 풍선도관에 대한 단기 조직 반응)

  • Yoo, Young-Sam;Choi, Chan;Kim, Dong-Won
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.1
    • /
    • pp.34-39
    • /
    • 2011
  • Objectives : This study was aimed to investigate soft tissue reaction such as inflammation, immune reaction of rabbit larynx to implanted foley catheter. Methods : After 8 rabbits were anesthetized, their thyroid cartilage and trachea were exposed through a skin incision and a 6 French foley catheter was inserted into the thyroid cartilage via cricothyroid membrane and ballooned with normal saline (0.1 mL). The other end of catheters were ligated and cut. The wound was closed keeping catheter under the skin. Two rabbits were used as normal control Larynges were removed for pathologic examination at 4weeks and 8 weeks of the study respectively, Results : Ten rabbits were euthanized for gross and pathologic examination (5 rabbits after 4 weeks and 5 rabbits after 8 weeks). All rabbits survived the study periods and inflammations or foreign body reactions were minimally found on pathologic examinations. Conclusions : Foley catheter could be useful and safe material for vocal fold medialization in rabbit models.

  • PDF

AN EXPERIMENTAL STUDY OF TISSUE REACTION OF ABSORBABLE SUTURE MATERIALS (수종(數種)의 흡수성(吸收性) 봉합사(縫合絲)가 조직반응(組織反應)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Song, Sun-Chul;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.381-390
    • /
    • 1991
  • The purpose of this study was to select the absorbable suture material with the lowest level of foreign body reaction in the extraoral field. The absorbable sutures tested were polyglactin 910(Vicryl), polyglycolic acid(Dexon), and chromic gut. Black silk served as to control suture. Eighteen domestic rabbits served as the animal model for testing purposes. After shaving the fur, A six centimeter incision was made in the hind quarter of all eighteen animals. Each wound was then closed wit two Vicryl, two Dexon, and two chromic gut sutures. All wounds were closed in the same manner. A similar wound was made on the oppsite side and closed with black silk suture. Three rabbits were then sacrificed on postoperative day one, three, seven fourteen, twenty-one, and twenty-eight. The surgical sites were then examined histologically. 1. On days one, three, and seven all suture materials as a similar severe level of inflammatory response. On the fourteenth day the inflammatory reaction of Vicryl was minimal, chromic gut was moderate, and Dexon was severe, Black silk control groups demosnstrated the most severe levels of inflammation of all sutures tested from day fourteen to twenty-eight. 2. On the fourteenth day all absorbable suture materials demonstrated similar minimal levels of resorption. At twenty-eight days Vicryl demonstrated a greater amount of resorption than Dexon or cromic gut suture. There was no resorption noted in the black silk control groups through day twenty-eight. 3. Due to its decreased level of inflammatory response in the animal model, Vicryl might be expected to as a decreased level of response in humans. It is felt that Vicryl is preferred to Dexon or chromic gut for extraoral suturing.

  • PDF