• Title/Summary/Keyword: Industrial Scientific Medical band

Search Result 70, Processing Time 0.036 seconds

2.5 GHZ SECOND-AND FOURTH-ORDER INDUCTORLESS RF BANDPASS FILTERS

  • Thanachayanont, Apinunt
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.86-89
    • /
    • 2002
  • A new design approach for realising low-power low-voltage high-Q high-order RE bandpass filter is proposed. Based on the gyrator-C inductor topology, a 2$\^$nd/-order biquadratic bandpass filter can be realised by adding a series capacitor to the input port of the gyrator. High-Q 2$\^$nd/-order and 4$\^$th/-order fully differential RF bandpass filters operating in the 2.4-㎓ ISM (Industrial, scientific and medical) frequency band under a 2-V single power supply voltage with low power dissipation are reported.

  • PDF

Performance Analysis of Bluetooth in Interference Environments (간섭 환경에서의 블루투스 시스템의 성능 분석)

  • 이규환;마중수;정영식
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10c
    • /
    • pp.274-276
    • /
    • 2001
  • 블루투스와 802.11 WLAN 과 같은 기술은 ISM(Industrial, Scientific and Medical) band에서 무선 기술을 제공할 수 있어 큰 기대를 같게 하는 기술이다. 하지만 ISM band블 사용하는 이 기술들은 서로 같은 대역을 사용하기 때문에 서로 간섭을 일으키며 서로 성능 저하의 요인이 된다. 본 논문에서는 다수의 블루투스 피코넷과 802.11 WLAN환경에서의 블루투스의 성능 저하를 분석한다.

  • PDF

Design of Dual-band Microstrip Antenna for ISM Bandwidth using Cross Patch (십자형 패치를 이용한 ISM 대역용 이중대역 마이크로스트립 안테나 설계)

  • 박기동;정문숙;임영석
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.241-245
    • /
    • 2002
  • Dual-band microstrip antenna is designed for industrial-scientific-medical(ISM) band of 2.4㎓ and 5.8㎓ using finite-difference time-domain method(FDTD). Cross Patch fed by aperture in the ground plane of microstrip line is proposed as radiation element of antenna, which is 2 rectangular Patch is overlapped. To design antenna, change of input impedance by aperture and stub length change is examined. And it is investigated that center frequency and -10 ㏈ bandwidth by Length of radiation element and width change. Experimental result about reflection Loss confirmed that agree well with analysis results of FDTD and IE3D, And -3 ㏈ beam width, front to back ratio and gain in frequency 2.43㎓ and 5.79㎓ is presented by measuring radiation Pattern of antenna.

  • PDF

Slotted Implantable Patch Antenna for ISM Band Application and Its Usage in WiMAX with an I-Shaped Defected Ground Structure

  • Ayubi, Adil Al;Sukhija, Shikha;Sarin, Rakesh Kumar
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.6
    • /
    • pp.359-363
    • /
    • 2017
  • A slotted implantable patch antenna with microstrip feeding is proposed for industrial, scientific, and medical band applications. The result is verified by implanting the antenna in animal tissue. Further, by varying the ground width and introducing a defect into the ground structure, the antenna becomes applicable for worldwide interoperability for microwave access operations. A simulation is performed using Empire XCcel software. An Agilent vector network analyzer is used for analyzing the return loss performance. Simulated and measured results are compared. Antennas with and without defected ground structure both have key advantages including low profile, desirable return loss, good impedance matching and required bandwidth.

The Research about improvement of receive sensitivity for RF module in ISM band (ISM 밴드 RF 모듈의 수신감도 향상에 관한 연구)

  • Lee, Hyuck-Jin;Yang, Oh
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.613-616
    • /
    • 2002
  • This paper has been studied an improvement of receive sensitivity for RF module of Industrial Scientific Medical(ISM) Band. In the paper, Also this paper handles receive sensitivity progress of RF module in ISM band. how to improve receive sensitivity adds to Surface Acoustic Wave(SAW) filter, Low Noise Filter(LNA), etc and insulates receiver and transmitter. And then the circuit is inspected by the effective range test of receiver and transmitter. And this Paper was designed that micro-controler controls the part of RF by software.

  • PDF

Compatibility between ISM Equipment and WiBro Service at 2.3 GHz band (2.3 GHz 대역의 ISM 기기와 WiBro 서비스의 양립성 분석)

  • Shim, Yong-Sup;Lee, Il-Kyoo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.101-105
    • /
    • 2011
  • This paper calculates protection distance to protect WiBro service from ISM(Industrial Scientific Medical) equipment which is used in the same frequency with WiBro. We analyze with a scenario that WiBro receiver is closed to ISM equipment which has interfering power of CISPR(International Special Committee on Radio Interference) 11 limit. As a result, the protection distance of 14 m was calculated by using MCL (Minimum Coupling Loss) for the worst case. And, the protection distance of 10 m was calculated to meet 5 % interference probability below by using MC(Monte Carlo) for statistic analysis in case of a interferer.

Interference Analysis based on the Monte-Carlo Method (Monte-Carlo 기반의 간섭분석에 관한 연구)

  • Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.2
    • /
    • pp.58-64
    • /
    • 2008
  • In this paper, we proposed the methodology of interference analysis based on monte-carlo method for effective use of Industrial, Scientific, Medical (ISM) band. The interference scenario is divided according to the distance and density. The simulation of interference analysis evaluates the interference probability according to distribution density of Interfering Transmitters (It) in the Secure Interference Area (SIA). The SIA is gained from the Interference Efficiency Range that satisfied to Interference Permissible Range of Victim Receiver (Vr). Simulation result that apply the proposed interference scenario to the WLAN and bluetooth, Interference Permissible Range was 60~400m. And the WLAN was acceptable within interference permissible range to six bluetooth that exist in the SIA. In the same condition, when applied Listen Before Talk (LBT) based on Cognitive Radio (CR) to the bluetooth using Frequency Hopping (FH), interference probability was decreased sharply. The Spectrum Engineering Advanced Monte Carlo Analysis Tool (SEAMCAT) that has been developed based on the monte-carlo method by European Radio-communications Office (ERO) were used to the interference simulation.

  • PDF

A Study on a Visible Light Communication using LED in Under-water Environment (LED조명을 이용한 수중환경에서의 VLC 연구)

  • Jung, Hui-Sok;Yang, Yeon-Mo;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.5
    • /
    • pp.1-6
    • /
    • 2011
  • LED(Light Emitting Diode) components have advantages of longer lifetime, lower power consumption and easy-to-control, compare to normal lamp and fluorescent light, according to the development of recent technologies. Thus, lots of illuminations which utilize LED components could be used. Recently, Visible Light Communication(VLC) which is a part of communication technologies, utilizing high speed response characteristic of LED components, started receiving public attention. In case of VLC, there is no need of frequency allocation due to no use of radio, but also no interference exists during data transmission, much different in ISM((Industrial Scientific Medical band). This is the reason why a lot of research results about VLC are becoming issued. In this paper, a survey of feasibility for using VLC utilizing an original LED illumination for underwater applications has been done and a primitive possibility of its application has been examined.

Implementation of a High Power Amplifier using Low Loss Radial Power Combiner and Water Cooling System (저 손실 레디알 전력 결합기와 수냉 시스템을 이용한 고전력 증폭기 구현)

  • Choi, Sung-Wook;Kim, Young
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.319-324
    • /
    • 2018
  • In this paper, a high power amplifier using RF power solid-state semiconductor is implemented to overcome a problem of plasma generator which has the low efficiency, short life span, the difficult maintenance and the high-operation cost. This power amplifier consists of a radial combiner of low-loss and high power operation and the sixteen 300 W power amplifiers to obtain 3 kW output power for high power operation implemented in semiconductors at industrial scientific medical (ISM) band of 2.45 GHz. In addition, this amplifier overcomes the problem of heat generation due to high power by applying a water-cooled structure to the individual amplifiers. This power amplifier, which is made up of a small system, achieves 50% efficiency at the desired output.

Dual-Band Microstrip Antenna for ISM Band using Aperture Coupled Cross Patch (개구 결합된 십자형 패치를 이용한 ISM 대역용 이중대역 마이크로스트립 안테나)

  • 박기동;정문숙;임영석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.5
    • /
    • pp.479-488
    • /
    • 2003
  • Dual-band microstrip antenna is designed for industrial-scientific-medical(ISM) band of 2.4 GHz and 5.8 GHz using finite-difference time-domain method(FDTD). Cross patch 130 by aperture in the ground plane of microstrip line is proposed as radiation element of antenna which is 2 rectangular patch is overlapped. To design antenna, change of input impedance is examined by length change of aperture and stub. And center frequency and - 10 dB bandwidth are investigated by change of length and width in radiation element. Measured result about reflection loss confirm that agree well with simulation results of FDTD and IE3D. And 3 dB beam width, front to back ratio and maximum gain is presented by measuring radiation pattern of antenna in frequency 2.43 GHz and 5.79 GHz.