• Title/Summary/Keyword: Industrial Computed Tomography

Search Result 68, Processing Time 0.026 seconds

Relationship between White Matter Changes and Homocysteine Concentration in Healthy Adults (건강한 성인에서 대뇌 백질 변성과 호모시스테인 농도의 연관성)

  • Hur, Wook;Kang, Hyun Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.449-455
    • /
    • 2018
  • This study was conducted to analyze the correlation between changes in white matter and homocysteine concentration through brain computed tomography of healthy 50-75 year old subjects without stroke or dementia history. We studied 722 out of 900 patients who underwent health screening at one hospital from 2016 to 2017. Based on the medical records, retrospective studies were conducted and analyzed using SPSS. A chi-square test, T-test and univariate logistic regression analysis were used for analysis. After the subjects were divided into the group with and without white matter changes, the population characteristics were analyzed. The mean age, homocysteine concentration and prevalence of hypertension and diabetes were higher and the duration of education was shorter in the group with white matter changes. In the group with white matter changes, the population increased as homocysteine concentration increased. When the odds ratio was compared based on the lowest group (Q1), age [p<0.001], hypertension [p<0.001] and hyperhomocysteinemia [p=0.021] were risk factors for white matter changes. We also identified modifiable risk factors such as hypertension and hyperhomocysteinemia to prevent complications of white matter changes. However, there has been no report of risk for the each causes of hyperhomocysteinemia and relationship between white matter changes and homocysteine concentration in Koreans. Therefore, large scale prospective studies are needed to better understand this topic.

Emergency preoperative angioembolization without computed tomography to treat unstable pelvic fractures with bowel perforation (장 천공을 동반한 혈역학적으로 불안정한 골반골 골절에서 전산화 단층촬영 전 시행한 혈관색전술의 지혈효과: 증례보고)

  • Park, Chan-Yong;Kang, Wu-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.417-422
    • /
    • 2019
  • Hemodynamically unstable pelvic fractures show a remarkably high mortality rate of 40% to 60%. However, their standard of care remains controversial. We report here a case of a 78-year-old woman who was admitted to the Emergency Department with pelvic pain following a fall. Based on pelvic radiography, she was diagnosed with an unstable pelvic fracture. Her blood pressure was 60/40 mmHg, and owing to her unstable vital signs, emergency angiography was performed without computed tomography (CT). Both internal iliac arteries were embolized without sub-branch selection for prompt control of pelvic bleeding. Following embolization, her vital signs were stabilized. Subsequent CT revealed free intra-abdominal air, suggesting bowel perforation had occurred and necessitating emergency laparotomy. An approximately 1 cm-sized free perforation of the small intestine was identified intraoperatively, and primary closure was performed. A retroperitoneal hematoma identified intraoperatively was not explored further because it was a non-expanding and non-pulsatile mass. The patient was admitted to the Intensive Care Unit and transferred to the general ward on postoperative day 3. In this case, the hemodynamically stable pelvic fracture with bowel perforation was successfully and safely treated by prompt angioembolization without conducting CT.

Emergency angioembolization performed in a hemodynamically unstable patient with grade V liver injury: The benefit of emergency angioembolization without computed tomography (혈역학적으로 불안정한 grade V 간손상에서 시행한 응급 혈관색전술: 전산화단층 촬영 없이 시행한 응급 혈관색전술의 이점)

  • Kang, Wu Seong;Park, Chan Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.235-239
    • /
    • 2019
  • High-grade liver injury is associated with high morbidity and mortality rates. We report successful emergency angioembolization and early interventional radiology support to manage a high-grade liver injury in a 29-year-old man who presented following a fall during parachute training. Upon arrival, his blood pressure was 80/40 mmHg, and emergency ultrasonography showed a liver injury with perihepatic fluid collection. The patient's blood pressure reduced to 60/40 mmHg, and emergency angiography was performed without computed tomography (CT) (door to puncture time 36 min). After angioembolization, his blood pressure returned to 120/77 mmHg. Subsequent CT revealed no additional bleeding or hollow viscus injury. He was admitted to the Intensive Care Unit and discharged without complications 30 days after admission. In this case, emergency angioembolization (without performing CT) could successfully and safely treat a hemodynamically unstable patient with a high-grade liver injury.

Recent Research Trend in Lateral Flow Immunoassay Strip (LFIA) with Colorimetric Method for Detection of Cancer Biomarkers (암 바이오마커 검출용 비색법 기반 측면 흐름 면역 크로마토그래피 분석법(LFIA) 스트립의 최신 연구 동향)

  • Lee, Sooyoung;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.585-590
    • /
    • 2020
  • Successful early diagnosis of cancer diseases such as lung, prostate, liver and adrenocortical carcinoma is a key step in determining the cost of treatment, survival rate, and cure rate. Most of current cancer diagnosis systems including biopsy, computed tomography (CT), positron emission tomography (PET)-CT, magnetic resonance imaging (MRI), ultrasonography, etc., require expensive and complicated equipment with highly trained human resources. Global medical and scientific communities have thus made numerous efforts on developing effective but rapid disease management system via introducing a wide spectrum of point-of-care medical diagnosis devices. Among them, a lateral flow immunoassay strip technique has gained a great attention due to many advantages such as cost-effectiveness, short inspection time, and user friendly accessibility. In this mini-review, we will highlight recent research trend on the development of colorimetry based LFIA strips for cancer diagnosis and discuss the future research direction and potential applications.

Spontaneously Occurring Chemodectoma in a Yorkshire Terrier Dog

  • Park, Chul;Yoo, Jong-Hyun;Kim, Dae-Young;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.25 no.3
    • /
    • pp.187-191
    • /
    • 2008
  • A 7-year-old, intact female Yorkshire terrier dog was presented for coughing, anorexia, chest pain and dyspnea. Right lateral thoracic radiograph demonstrated a large mass shape on the heart base with decreased cardiac silhouette and severe right deviation of the trachea with the heart shifted to the left thoracic wall was observed on the ventrodorsal thoracic projection. Echocardiographic examination revealed a large rounded mass compressing left atrium around the heart base without signs of pericardial effusion. On computed tomographic (CT) findings, sagittal CT images depicted the possibility of cranial vena caval invasion and heart base involvement of the mass associated with biatrial compression. Dorsal CT image revealed the right deviation of trachea due to the heart base mass and markedly shrunk lung space was detected on the transverse CT image. Because the dog suddenly had died during the recovery from anesthesia after finishing CT scan, necropsy was performed. On gross findings, a large and lobulated mass was located at the base of the heart. A poorly-demarcated, infiltrative, multilobulated tumor composed of polyhedral cells in solid cellular sheets was confirmed based on histopathologic examination. This dog was diagnosed as a chemodectoma. This case report describes the clinical findings, diagnostic consistency of thoracic radiography, echocardiography and CT, and histopathologic confirmation in a spontaneously occurring chemodectoma with a Yorkshire terrier dog.

Identification and Three-Dimensional Characterization of Micropore Networks Developed in Granite using Micro-Focus X-ray CT

  • Choo, Chang-Oh;Takahashi, Manabu;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.24 no.2
    • /
    • pp.179-189
    • /
    • 2014
  • We analyzed the three-dimensional distribution of micropores and internal structures in both fresh and weathered granite using micro-focus X-ray computed tomography (micro-CT). Results show that the pore radius in fresh granite is mostly in the range of $17-50{\mu}m$, the throat radius is in the range of $5-25{\mu}m$, and the coordination number (CN) of pores is less than 10. In contrast, the pore radius in weathered granite is mostly in the range of $20-80{\mu}m$, the throat radius is in the range of $8-30{\mu}m$, and the CN is less than 12. In general, a positive linear relationship exists between pore radius and CN. In addition, both the size and the density of pores increase with an increasing degree of rock weathering. The size of the throats that connect the pores also increases with an increasing degree of weathering, which induces fracture propagation in rocks. Micro-CT is a powerful and versatile approach for investigating the three-dimensional distributions of pores and fracture structures in rocks, and for quantitatively assessing the degree of pore connectivity.

Case Report of Asbestosis

  • Lee, Yong-Hwan;Chang, Hee-Kyung;Kiyoshi Sakai;Naomi Hisanaga;Chung, Yong-Hyun;Han, Jeong-Hee;Yu, Il-Je
    • Toxicological Research
    • /
    • v.17 no.3
    • /
    • pp.163-165
    • /
    • 2001
  • A patient,58 years of age, with suspected 0/l pneumoconiosis since 1993, complained of a dry cough and exertioning dyspnea for 6 months. He had worked in an asbestos company for more than 20 years from 1974. He was subsequently diagnosed with an interstitial lung disease during an annual special health check-up for asbestos workers. h chest X-ray showed an interstitial lung disease and high-resolution computed tomography (HRCT) showed a round opaque asbestosis with chronic hypersensitivity pneumonitis. A pulmonary function test indicated that the patient had a mild restrictive lung disease with FEV1 1.67 litters and 82% FEVl/FVC. The bronchoalveloar larvage fluid included many asbestos bodies, indicating previous exposure to asbestos. Transmission electron microscopy (TEM) using an energy dispersive X-ray analyzer (EDX) revealed many asbestos bodies consisting of mainly crocidolite fibers (6,071$\times$$10^6$fibers/g of dry lung). The patient had an unusually high asbestos content of 6,112$\times$$10^6$ asbestos fibers/9 of dry lung.

  • PDF

Correction of Single Photon Emission CT Image Distorted by Collimator Characteristic (시준기의 특성으로 인한 SPECT 왜곡 화상의 보정)

  • 백승권
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2004
  • SPECT technology is used for the reconstructed image in the field of industry noncontact measurement system. One of the distortion problems in reconstructed image quality is a collimator characterictic. The image distortion is caused by a geometrical structure of the collimator. This paper indicated a correction method to remove the image distortion by the structure of the collimator, and compared with the existing correction method. The correction. method removed the image distortion to use deconvolution of projection data with the shift-variant blurring function in the frequency domain. In this pater, I simulated with the collimator angle and distance between the detector and the center of object. and verified with expeimental data. The validity and limitation of correction method is studied for actual industrial applications.

  • PDF

MR Imaging Measurement of the Femoral Anteversional Angle as a PACS Image Viewer (MR 영상에서의 PACS Image Viewer를 이용한 대퇴골 전염각 측정)

  • Kweon, Dae-Cheol;Yang, Sung-Hwan;Park, Peom
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.83-89
    • /
    • 2003
  • The accurate measurement of the femoral anteversion is very important to the practice of orthopedic and osteotomy. It is measured by means of the axis of head and neck of the femur and the knee axis. At the present time, widely used computed tomography method of measuring anteversion on femoral necks of patients. Measurement by the manual method and image viewer of computed tomography to determine the anteversion of femoral head were carried out on both femurs. In September and October 2002, 5 patients 28 to 36 years of age were randomly selected from Seoul National University Hospital. The purpose of this paper was to introduce a new method to measure femoral anteversion angle utilizing PACS image viewer program in the MR imaging. Significant difference was observed between the right and left side the image viewer measurement of femoral anteversion. In conclusion, MR imaging very usefulness in the measured the angle of the femoral anteversion.

  • PDF

A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination (흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구)

  • Kim, Young-Keun;Yang, Sook;Wang, Tae-uk;Kim, Eun-Hye
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.