• Title/Summary/Keyword: Industrial Building

Search Result 2,225, Processing Time 0.029 seconds

The establishing Korean Industrial Standard of the sound absorber for use in building (흡음률 평가방법의 KS 규격화 방안에 관한 연구)

  • Lee, Tai-Gang;Song, Min-Jung;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.939-944
    • /
    • 2002
  • Recently Korean Industrial Standards has been revised and established newly accordance with the ISO system, especially ISO 140 series. This study aims to introduce and review ISO 11654 which contents rating of sound absorption, and then this study suggests to establish appropriate evaluating method and Korean Industrial Standard of the sound absorber for use in building.

  • PDF

The Assessment for Environmental Stabilization of Ground Solidification Materials using Industrial y-product (산업부산물을 활용한 지반고화재의 환경안정성 평가)

  • Lee, Yeong Won;Mun, Gyeong Ju
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.116-117
    • /
    • 2014
  • This study is to environmental safety assessment of ground solidification materials using industrial by-products. also, physical and chemical properties were investigated. as a result, compared to conventional cement the survival rates are capable, was judged to be possible utilizing of ECO-friendly ground solidification materials.

  • PDF

Study on the Development of Protective Walls to prevent the spread of Ultra-Fast Fire in Small Industrial Facilities (소규모 산업시설의 초고속 화재 확산 방지를 위한 방호벽체 개발 연구)

  • Choe, Gyeong-Choe;Kim, Hong-Seop2
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.275-276
    • /
    • 2023
  • This study introduces the current progress of study on the development of protective wall aimed at preventing the spread of ultra-fast fires and ensuring fire safety in industrial facilities.

  • PDF

Compressive Strength Characteristics of Steam Curing Mortar according to Substitution Rate of Industrial By-Products (산업부산물의 치환율에 따른 증기양생 모르타르의 압축강도 특성)

  • Shin, Kyoung Su;Hwang, Sun Kyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.177-178
    • /
    • 2023
  • This study evaluated the compressive strength characteristics of steam curing mortar according to the substitution rate of industrial by-products, and showed a tendency to increase the compressive strength when gypsum was substituted up to 30%.

  • PDF

Architecture Study for SDDC BAS (SDDC BAS의 아키텍처에 관한 연구)

  • Kim, Jeong-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.646-651
    • /
    • 2015
  • In this paper, we analyze the architecture of a typical building automation systems and control points in the network architecture, interoperability, and performance aspects. We proposed a new virtualization-based point-to-point automatic control system that is connected to a high speed wired system. Cloud computing based automation system enables the user based environment control, and may perform a building energy management performance through the improvement of the building automation system efficiently In addition, the virtualization system makes it possible to perform the management of the group building load management operators efficiently.

Digital Technologies for Freeform Building in Korea (국내 비정형건축의 디지털 기술적용에 관한 연구)

  • Ryu, Jeong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4259-4265
    • /
    • 2012
  • Digital technologies and raising problems in freeform building design and construction in Korea were examined in this paper. Three Korean building cases were researched by having interviews with experts and documentary survey for this purpose. The following problems and important points were drawn from this research. The necessity of panel optimization, significance of the secure file conversion, difficulties in securing constructability of freeform building and using of 3D data for manufacturing panels.

Construction management Learning Model Applying Team-Based Learning and Flipped Learning (팀기반학습과 플립러닝을 적용한 건축시공 학습모형)

  • Noh, Ju-Seong;Lim, Hyung-Eun;Kim, Jae-Yeob
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.69-70
    • /
    • 2018
  • With increased interest in the Fourth Industrial Revolution, there is also a growing interest in the innovation of college education. In this regard, this study aims to develop a learning model for building construction to nurture architectural engineers needed in the era of the Fourth Industrial Revolution. To this end, it analyzed the previous studies on the recent innovations in engineering education. Among the educational innovation methods presented in the previous research, a new learning model was derived by using the most suitable method for the building construction eduction. The derived learning model is a building construction learning model applying team-based learning and flipped learning. The learning model proposed in this study was developed as a learning method to nurture engineers needed in the future. Therefore, it is expected that this model can be utilized in the eduction of architectural engineering at universities in Korea.

  • PDF

Performance Monitoring Study of Building Integrated Geothermal System in Winter (건물일체형 지열시스템의 동계 성능 모니터링 연구)

  • Yu, Hyung-Kyu;Bae, Sang-Hwan
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • The objective of this study is to develope ground heat exchanger using PHC pile used to building foundation, and it's element technology. So we made PHC piles into ground heat exchanger and evaluate it's performance. First, we studied PHC pile type, heat exchanger pipe, grouting materials, and present apartment house's foundation condition for PHC ground heat exchanger. As a result we designed BIGS(Building Integrated Geothermal System) prototype. Second, we applied BIGS to apartment houses' utility building in Osan built by Daelim. Third, we monitored heating performance of winter season. 1be result of heating performance was so good to apply to heat & cooling system in building.

Building System Analysis and Integration: Case Study on Richards Medical Research Building (건물시스템의 분석과 통합 방법에 관한 연구: 리차즈 의학 연구소 건물의 사례분석을 중심으로)

  • Choi, Joon-Sung;Im, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1444-1451
    • /
    • 2011
  • The purpose of this paper is to provide an understanding of building systems and to propose methods of building system analysis and integration. Building components are classified into four major systems; structure, mechanical, envelope, and interior system. There are 11 combinations between major systems. Three integration modes(physical, visual, and functional integration) and 12 integration strategies are proposed. A case study of Richards Medical Research Buildings designed by Louis I. Kahn was conducted from the perspective of building system analysis and integration.

Harmonic Excitation of Shear Building with Force-Controlled Shaking Table (힘-제어 진동대를 이용한 전단건물의 조화진동)

  • Lee, Sang Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.853-859
    • /
    • 2015
  • 1-DOF shear building was designed, built and tested to investigate the interactions between the shear building and the shaking table excited harmonically by the electro-magnetic forces. In the experiments horizontal accelerations of the shaking table and the shear building were measured. To understand the experimental results experimental setting was modeled as an unconstrained 2-DOF system under the hormonic forces. The responses of the shear building and the shaking table of the unconstrained 2-DOF system were found with the equations of motions. The magnification factors of the table and the shear building with respect to the amplitude of the harmonic forces and the transmission of the shear building with respect to the table excitations were found and compared with the experimental results.