• Title/Summary/Keyword: Inductively coupled plasma mass

Search Result 356, Processing Time 0.026 seconds

Determination of Trace Elements in Organic Tissues of Rat by Inductively Coupled Plasma-Mass Spectrometry (유도결합 플라즈마 질량분석기를 이용한 흰쥐 장기중의 극미량원소의 분석)

  • 강종성;김효진
    • YAKHAK HOEJI
    • /
    • v.37 no.6
    • /
    • pp.577-580
    • /
    • 1993
  • The trace elements in liver, kidney and testicle of rats were analysed by Inductively Coupled Plasma-Mass Spectrometer(ICP-MS). Ten elements(Cr, Ni, Cu, Zn, Mo, Cd, Pb, Bi, Th, U) were determined simultaneously and the detection limit of each elements was lower than ppb level.

  • PDF

Determination of Trace Elements in Animal Feed by Inductively Coupled Plasma-Mass Spectrometry (유도결합 플라즈마 질량분석기를 이용한 동물사료중의 극미량원소의 분석)

  • Park, Jeoung-Hwa;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.36 no.3
    • /
    • pp.199-204
    • /
    • 1992
  • The trace elements in animal feed were analyzed by Inductively Coupled Plasma Mass Spectrometer (ICP-MS, VG-PlasmaQuad Co.) to find possible sources of heavy metals accumulation in rat organ. The study about spectral interference was performed by analysis of a background spectrum of ICP-MS. Recovery test using standard of Cd and Se (100 ppb) was found to be better than 90%. Twenty elements (Ca, Fe, Mg, Ti, Cr, Ni, Cu, Zn, Ba, Al, Mn, Pb, B, Ce, Bi, U, V, Cd, and W)are determined.

  • PDF

QMF Ion Beam System Development for Oxide Etching Mechanism Study (산화막 식각 기구 연구를 위한 QMF Ion Beam 장치의 제작)

  • 주정훈
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.4
    • /
    • pp.220-225
    • /
    • 2004
  • A new ion beam extraction system is designed using a simple ion mass filter and a micro mass balance and a QMS based detecting system. A quadrupole Mass Filter is used for selective ion beam formation from inductively coupled high density plasma sources with appropriate electrostatic lens and final analyzing QMS. Also a quartz crystal microbalance is set between a QMF and a QMS to measure the etching and polymerization rate of the mass selected ion beam. An inductively coupled plasma was used as a ion/radical source which had an electron temperature of 4-8 eV and electron density of $4${\times}$10^{11}$#/㎤. A computer interfaced system through 12bit AD-DA board can control the pass ion mass of the qmf by setting RF/DC voltage ratio applied to the quadrupoles so that time modulation of pass ion's mass is possible. So the direct measurements of ion - surface chemistry can be possible in a resolution of $1\AA$/sec based on the qcm's sensitivity. A full set of driving software and hardware setting is successfully carried out to get fundamental plasma information of the ICP source and analysed $Ar^{+}$ beam was detected at the $2^{nd}$ QMS.

Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Characterization of U-7Mo/Al-5Si Dispersion Fuels

  • Lee, Jeongmook;Park, Jai Il;Youn, Young-Sang;Ha, Yeong-Keong;Kim, Jong-Yun
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.645-650
    • /
    • 2017
  • This technical note demonstrates the feasibility of using laser ablation inductively coupled plasma mass spectrometry for the characterization of U-7Mo/Ale5Si dispersion fuel. Our measurements show 5.0% Relative Standard Deviation (RSD) for the reproducibility of measured $^{98}Mo/^{238}U$ ratios in fuel particles from spot analysis, and 3.4% RSD for $^{98}Mo/^{238}U$ ratios in a NIST-SRM 612 glass standard. Line scanning allows for the distinction of U-7Mo fuel particles from the Al-5Si matrix. Each mass spectrum peak indicates the presence of U-7Mo fuel particles, and the time width of each peak corresponds to the size of that fuel particle. The size of the fuel particles is estimated from the time width of the mass spectrum peak for $^{98}Mo$ by considering the scan rate used during the line scan. This preliminary application clearly demonstrates that laser ablation inductively coupled plasma mass spectrometry can directly identify isotope ratios and sizes of the fuel particles in U-Mo/Al dispersion fuel. Once optimized further, this instrument will be a powerful tool for investigating irradiated dispersion fuels in terms of fission product distributions in fuel matrices, and the changes in fuel particle size or shape after irradiation.

Determination of Ni, Cr, Mo in Low Alloy Steel Reference Materials by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry (동위원소희석 유도결합플라스마질량분석법에 의한 저 합금강 표준시료중의 Ni, Cr, Mo의 분석)

  • Suh, Jungkee;Woo, Jinchoon;Min, Hyungsik;Yim, Myeongcheul
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.82-89
    • /
    • 2003
  • Isotope dilution mass spectrometry (IDMS) was applied to the determination of Ni, Cr, Mo in low alloy steel reference materials. The Mo isotope ratio measurement was performed by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP/MS) using ammonia as a reaction cell gas. In the case of Ni and Cr measurement, all data were obtained at medium resolution mode (m/${\Delta}m=3000$) of double focusing sector field high resolution inductively coupled plasma mass spectrometry (HR-ICP/MS). For the method validation of the technique was assessed using the certified reference materials such as NIST SRM 361, NIST SRM 362, NIST SRM 363, NIST SRM 364, NIST SRM 36b. This method was applied to the determination of Ni, Cr and Mo in low alloy steel sample (CCQM-P25) provided by NMIJ for international comparison study.

Elemental Analysis of Coal by Inductively Coupled Plasma Mass Spectrometry (誘導結合플라스마 質量分析法에 의한 石炭의 元素 分析)

  • 이용근;고인형;이동수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.155-161
    • /
    • 1992
  • A simple, fast yet sensitive method is described for the determination of fifty elements in coal by inductively coupled plasma mass spectrometry. The method involves complete dissolution of coal with mixed acid $(HNO_3, HF, HClO_4)$ in hish pressure Teflon bomb and subsequent inductively coupled plasma mass spectrometric(ICP-MS) measurement. The accuracy of the method, being evaluated by the analysis of NIST SRMs (1632a, 1632b) is better than 20% RSD for most elements. The limits of detection defined by two times $\sigma$ (standard deviation of operational blank) are in order of sub-ppm to ppm, which are low enough to quantitate most elements. However, the determiantions for few elements such as V, As, Se are severely interfered by molecular ions such that their accurate determiantions are not possible. Analytical results for twentyon coals from eight countries including six ones world major coal producing, Korea, Japan, China, I.C.S., U.S.A., Canada, Australia, and South Africa are presented. While the results for major elements agree well with the existing ones, those for a few trace elements disagree considerably. The existing values are considerably higher. It is not possible to judge which are more accurate. However, the exisisting values are more likely to be errorous inasmuch as they are obtained without using high purity reagents and clean laboratory techniques.

  • PDF

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY FOR THE DETERMINATION OF 237Np IN SPENT NUCLEAR FUEL SAMPLES BY ISOTOPE DILUTION METHOD USING 239Np AS A SPIKE

  • Joe, Kihsoo;Han, Sun-Ho;Song, Byung-Chul;Lee, Chang-Heon;Ha, Yeong-Keong;Song, Kyuseok
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.415-420
    • /
    • 2013
  • A determination method for $^{237}Np$ in spent nuclear fuel samples was developed using an isotope dilution method with $^{239}Np$ as a spike. In this method, inductively coupled plasma mass spectrometry (ICP-MS) was taken for the $^{237}Np$ instead of the previously used alpha spectrometry. $^{237}Np$ and $^{239}Np$ were measured by ICP-MS and gamma spectrometry, respectively. The recovery yield of $^{237}Np$ in synthetic samples was $95.9{\pm}9.7$% (1S, n=4). The $^{237}Np$ contents in the spent fuel samples were 0.15, 0.25, and $1.06{\mu}g/mgU$ and these values were compared with those from ORIGEN-2 code. A fairly good agreement between the measurements (m) and calculations (c) was obtained, giving ratios (m/c) of 0.93, 1.12 and 1.25 for the three PWR spent fuel samples with burnups of 16.7, 19.0, and 55.9 GWd/MtU, respectively.

Diagnostics of Inductively Coupled $BCl_3/Ar$ Plasma Characteristics Using Quadrupole Mass Spectrometer (사중극자 질량 분석기를 이용한 $BCl_3/Ar$ 유도결합 플라즈마 특성 진단)

  • Kim, Gwan-Ha;Kim, Chang-Il
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.204-208
    • /
    • 2006
  • In this study, we investigated the ion energy distributions in a chlorine based inductively coupled plasma by quadrupole mass spectrometer with an electrostatic ion energy analyzer. Ion energy distributions are presented for various plasma parameters such as $BCl_3/Ar$ gas mixing ratio, RF power, and process pressure. As the $BCl_3/Ar$ gas mixing ratio and process pressure decreases, and RF power increases, the saddle-shaped structures is enhanced. The reason is that there are ionized energy difference between $BCl_3$ and Ar, change of plasma potential, alteration of mean free path. and variety of ion collision in the sheath.

Direct Determination of Total Arsenic and Arsenic Species by Ion Chromatography Coupled with Inductively Coupled Plasma Mass Spectrometry

  • Nam, Sang-Ho;Kim, Jae-Jin;Han, Soung-Sim
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1805-1808
    • /
    • 2003
  • The simultaneous determination of As(III), As(V), and DMA has been performed by ion chromatography (IC) coupled with inductively coupled plasma-mass spectrometry (ICP-MS). The separation of the three arsenic species was achieved by an anionic separator column (AS 7) with an isocratic elution system. The separated species were directly detected by ICP-MS as an element-selective detection method. The IC-ICP-MS technique was applied for the determination of arsenic species in a NIST SRM 1643d water sample. An As(III) only was detected in the sample. The detection limits of As(III), As(V) and DMA were 0.31, 0.45, and 2.09 ng/mL, respectively. It was also applied for the determination of arsenic species in a human urine obtained by a volunteer, and three arsenic species were identified. The determination of total As in human urines that were obtained from 25 volunteers at the different age was also carried out by ICP-MS.