• 제목/요약/키워드: Induced Discharge

검색결과 349건 처리시간 0.029초

디젤 연료분사노즐 색크실내의 압력과 유동패턴이 분류의 분열거동에 미치는 영향 (Effect of the Pressure and the Flow Pattern in a Sac Chamber of a Diesel Injection Nozzle on the Issued Spray Behaviors)

  • 김장헌;송규근
    • 한국자동차공학회논문집
    • /
    • 제8권1호
    • /
    • pp.48-53
    • /
    • 2000
  • The effects of the internal flow in a diesel injection nozzle on the atomization of the spray has been investigated experimentally. Flow visualization was made using a transparent acrylic model nozzle. And also, measurement of the sac chamber pressure was made for clartfying the effect of pressure fluctuation in the sac chamber on the wpray behaviors. The geometry of the model nozzle was scaled up 10 times of the actual nozzle and the injection pressure for the model nozzle was adjusted so as to achieve a Reynolds number at the discharge hole which was the same as the actual nozzle. Polystyrene tracers, a laser sheet light and a still/high speed video camera were used to visualize the flow pattern in the sac chamber. When the needle lift was small, the high turbulence in the sac chamber generated by the high velocity seat flow made the spread angle of the spray large. Cavitation which arose in the sky chamber induced the pressure fluctuation and then affects the spread angle of the spray.

  • PDF

노후 차량의 배기가스 측정을 이용한 산소센서, 인젝터, 점화2차파형의 파형분석 연구 (A Study on Waveform Analysis of Oxygen Sensor, Injector and Secondary Waveform through Emission Characteristics by a Decrepit Vehicle)

  • 유종식;김철수
    • 한국자동차공학회논문집
    • /
    • 제21권5호
    • /
    • pp.151-156
    • /
    • 2013
  • The experiment was done on cars travelling at the speeds of 20km/h, 60km/h and 100km/h using the performance testing mode for chassis dynamometer. In this experiment, the relativity between the secondary waveform coming from ignition coil and exhaust emissions were measured in case of cars with failures, in oxygen sensor, spark plugs. The following results obtained by analysis of the relativity between the secondary waveform and exhaust emissions. 1) When the oxygen sensor is failure, the average value of CO emission measured was 6.8 times higher than the standard CO emission value and the average value of HC emission measured was 2.3 times higher than the standard emission level. 2) When engine parts are in failure, more fuel enters the cylinder due to longer opening duration of injector, and it tended to make CO and HC emission values increase. 3) Combustion duration, the shape of flame propagation during spark line, and the size of the discharge-induced energy were the three main elements that directly cause variations in CO and HC emission values.

체내대사를 이용한 핵의학적 검사의 선량률 저감에 관한 연구 (Study in vivo metabolism using nuclear medical examination of the dose rate reduction)

  • 강용길;나수경;홍진웅;이귀원;김낙상
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.75-81
    • /
    • 2012
  • The purpose of this study was administered to the body for examination and treatment, high-energy radioactive isotope(F-18, I-131) in vitro discharge experiments. Increasing exposed dose of radiation to health professionals is caused by the increase of PET/CT use and a radioactive isotope. Therefore, the high-energy isotope F-18 and I-131 after administration about using Metabolite excretion was studied. As a results of this study, patients had plenty of fluids for testing and treatment alone administered radiopharmaceuticals can be more than twice as fast excretion induced emissions. Also was able to get a better image space to reduce the dose rate.

  • PDF

통신용 증폭기의 ESD 고장분석과 대책 (Failure Analysis and Solution of ESD for Amplifier Used in Telecommunication)

  • 황순미;정용백;김철희;이관훈
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제11권3호
    • /
    • pp.251-265
    • /
    • 2011
  • Low-noise amplifier(LNA) is a component that amplifies the signal while lowering the noise figure of high-frequency signal. LNA holds a very important position in RF system so that it is widely used for telecommunication. Electro static discharge(ESD) is the most common cause of malfunction for low-powered components, such as Large Scale Integration and IC type LNA is weak in ESD. This thesis studies static effect of communication LNA. It analyzes ESD effect, which occurs within LNA circuit, and describes testing standard and methods. In order to find out LNA's susceptiblity to electro static, two well-recognized communication IC type LNA models were selected to be tested. Then static-induced malfunction was carefully analyzed and it suggests architectural problem and improvement from the LNA's ESD point of view.

슈퍼 커패시터용 전극을 위한 Polyvinylidene chloride(PVDC)-resin과 Mg(OH)2 템플릿으로부터 메조기공 탄소의 제조 (Fabrication of Mesoporous Carbon from Polyvinylidene Chloride(PVDC)-resin Precursor with Mg(OH)2 Template for Supercapacitor Electrode)

  • 황버들;전상은
    • 한국표면공학회지
    • /
    • 제52권6호
    • /
    • pp.326-333
    • /
    • 2019
  • The microporous carbon derived from PVDC-resin by a simple heat-treatment under an inert atmosphere exhibits a reasonable specific capacitance for a supercapacitor's electrode. However, the capacitance was rapidly decreased at high charge/discharge rate. The micropores present in an electrode surface hinder the entrance of an electrolyte ion onto the entire surface. To induce the meso-sized pores during the carbonization of PVDC-resin, Mg(OH)2 was utilized as a hard template. The porous carbon made from the mixture of PVD-Cresin and Mg(OH)2 include mesopores as well as micropores. The induced mesopores does not homogeneously distributed on the entire surface of the synthesized carbon. The PVDC-resin and Mg(OH)2 are dissolved in the dimethylformamide for the hard template to evolve the pores on the synthesized carbon uniformly. The carbon made from PVDC-resin with solvent and a hard template contains mostly mesopores resulting in the high power performance. The reduced amount of solvent in the precursor derives the carbon with high specific surface area and high power density.

Jet-grouting in ground improvement and rotary grouting pile installation: Theoretical analysis

  • Wang, You;Li, Lin;Li, Jingpei;Sun, De'an
    • Geomechanics and Engineering
    • /
    • 제21권3호
    • /
    • pp.279-288
    • /
    • 2020
  • The permeation grouting is a commonly used technique to improve the engineering geology condition of the soft ground. It is of great significance to predict the permeation range of the grout so as to ensure the effects of grouting. This paper conducts a theoretical analysis of jet-grouting effects in ground improvement and rotary grouting pile installation by utilizing deformation-permeation coupled poroelastic solutions based on Biot's theory and Laplace-Fourier integral transform technique. The exponential function and the intermittent trigonometric function are chosen to represent time-dependent grouting pressure usually encountered in ground improvement and rotary grouting pile installation process, respectively. The results, including the radial displacement, the hoop stress, the excess pore fluid pressure, the radial discharge, and the permeation radius of grout, are presented for different grouting time, radial positions and grouting lengths. Parametric study is conducted to explore the effects of variation of the exponent in the exponential grouting pressure-time relationship on grouting-induced responses. It is expected that the proposed solutions can be used to estimate the permeation range of grouting in ground improvement and rotary grouting pile installation.

해안지형의 장기적 변화에 따른 도로 구조물 설계하중 고려 요소에 관한 연구 (The design load factor of road structure considering long-term coastal geographic change)

  • 배선학;강상혁
    • 한국지형학회지
    • /
    • 제20권1호
    • /
    • pp.75-83
    • /
    • 2013
  • 해안지역의 인위적 간섭은 토사의 생산 및 유출에 의해 지형적인 변동을 유발한다. 더욱이 해안변동을 안정화시키기 위한 구조물의 설치가 다른 지역의 지형을 변화시키는 요인이 되기도 한다. 그러나 대부분 해안지역에 대한 토사 유출자료는 구축되어 있지 않은 실정이다. 본 연구는 장기적인 해안변동 경향, 해안변동의 주요 인자인 토사유출의 정량적인 평가 방안, 그리고 이를 고려한 접속도로의 설계하중에 영향을 미치는 요소에 대해 적절한 방향을 제시하고자 한다.

Treatment of severe pain in a patient with complex regional pain syndrome undergoing dental treatment under general anesthesia: A case report

  • Rhee, Seung-Hyun;Park, Sang-Hun;Ha, Sung-Ho;Ryoo, Seung-Hwa;Karm, Myong-Hwan;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제19권5호
    • /
    • pp.295-300
    • /
    • 2019
  • Complex regional pain syndrome (CRPS) is rare, characterized by pain from diverse causes, and presents as extreme pain even with minor irritation. General anesthesia may be required for dental treatment because the pain may not be controlled with local anesthesia. However, treatment under general anesthesia is also challenging. A 38-year-old woman with CRPS arrived for outpatient dental treatment under general anesthesia. At the fourth general anesthesia induction, she experienced severe pain resulting from her right toe touching the dental chair. Anesthesia was induced to calm her and continue the treatment. After 55 minutes of general anesthesia, the patient still complained of extreme toe pain. Subsequently, two administrations for intravenous sedation were performed, and discharge was possible in the recovery room approximately 5 h after the pain onset. The pain was not located at the dental treatment site. Although the major factor causing pain relief was unknown, ketamine may have played a role.

KM-based Treatment of Viral Hepatitis A accompanied with Pancreatitis: A case report

  • Son, Chang-Gue
    • 대한한의학회지
    • /
    • 제41권4호
    • /
    • pp.106-111
    • /
    • 2020
  • Objectives: Hepatitis A is a typical acute hepatitis caused by hepatovirus, and then most patients recover easily without progression to chronic condition. However, certain cases have the risk of severe symptoms or even death. This case report presented a hepatitis A accompanied with pancreatitis, which had been completely recovered in a Korean medicine hospital. Case presentation: A 38-year woman had felt the malaise, mild chilling, muscle pain and abdominal discomfort for 10 days, which led her visit doctors and took anti-pyretic analgesics and digestants. The symptoms, especially epigastric pain and fatigue, became worse, and then she hospitalized in a Korean medicine hospital. Based on the drastic elevations of hepatic enzymes (aspartate transaminase 1,604 IU/L and alanine transaminase 2,825IU/L) with an anti-HAV IgM positive, she was diagnosed with hepatitis A. After bed rest and herbal drug treatment (CGX and Innae-Tang) for 5 days, the laboratory abnormalities and subjective symptoms had been improved gradually, except the upper gastric discomfort and pain. Those symptoms had anticipated the comorbidity with HAV-induced pancreatitis, supported by the high level of serum lipase release. Another 5-day hospitalized treatment improved all subjective symptoms and then the laboratory results were completely normalized including detection of anti-HAV IgG within 15 days after discharge. Conclusion: This study presented a typical hepatitis A accompanied with pancreatitis, which should be considered in diagnosis and management of hepatitis A.

An assessment of the mechanical behavior of zeolite tuff used in permeable reactive barriers

  • Cevikbilen, Gokhan
    • Geomechanics and Engineering
    • /
    • 제31권3호
    • /
    • pp.305-318
    • /
    • 2022
  • Permeable reactive barriers used for groundwater treatment require proper estimation of the reactive material behavior regarding the emplacement method. This study evaluates the dry emplacement of zeolite (clinoptilolite) to be used as a reactive material in the barrier by carrying out several geotechnical laboratory tests. Dry zeolite samples, exhibited higher wetting-induced compression strains at the higher vertical stresses, up to 12% at 400 kN/m2. The swelling potential was observed to be limited with a 3.5 swell index and less than 1% free swelling strain. Direct shear tests revealed that inundation reduces the shear strength of a dry zeolite column by a maximum of 10%. Falling head permeability tests indicate decreasing permeability values with increasing the vertical effective stress. Regarding self-loading and inundation, the porosity along the zeolite column was calculated using a proposed 1D numerical model to predict the permeability with depth considering the laboratory tests. The calculated discharge efficiency was significantly decreased with depth and less than 2% relative to the top for barrier depths deeper than 20 m. Finally, the importance of directional dependence in the permeability of the zeolite medium for calibrating 2D finite element flow analysis was highlighted by bench-scale tests performed under 2D flow conditions.