• Title/Summary/Keyword: Indoor pollutants

Search Result 327, Processing Time 0.024 seconds

Effective Control of Indoor Air Pollutant using VAV/BPFS (VAV/BPFS를 이용한 실내공기 오염물질의 효율적 제어)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.327-334
    • /
    • 1998
  • The oil crisis of the 1970s and the rise in oil prices motivated people to implement energy conservation strategies. Buildings were fitted with additional Insulation and reduced ventilation rates. The reduction of mechanical and natural ventilation rate led to Increases In Indoor pollutant concentrations which result- ed In Increased health risks from Indoor exposure to pollutants. The variable-air-volume /bypass fitration system/VAV/BPFS) is a variation of the conventional VAV systems, The VAV/BPFS is an electronically controlled system that provides costegectlve thermal comfort and acceptable indoor air quality Under controlled conditions In a chamber, a series experiments were performed to compare the ability of a VAV/BPFS to remove Indoor aerosol concentration and to reduce energy consumption no that ability of conventional VAV system. Results show that the VAV/BPFS Increases the effective ventilation rate and removes indoor air pollutant, and maintains acceptable indoor air Quality without sacrificing energy consumption.

  • PDF

Efficiency of Removal for Indoor air pollutants by Air Cleaners in the Indoor Environments (공기청정기의 일부 실내공기 오염물질 제거효율에 관한 연구)

  • Lee Tae-Hyung;Kim Yoon-Shin;Hong Seung-Cheol;Lee Cheol-Min;Kim Jong-Cheol;Jeon Hyung-Jin;Kim Jung-Ho
    • Journal of Environmental Science International
    • /
    • v.14 no.5
    • /
    • pp.491-497
    • /
    • 2005
  • In this study, we investigated $PM_{10},\;NO_2$, and l-hydroxypyrene(1-OHP) in urine at indoor environments which are 35 houses and 20 hospitals for using air cleaner and non-using air cleaner in Seoul metropolitan area and Kyoung-gi province from April, 2003 to February, 2004. Moreover, we examined effect of improvement for indoor air quality and health effect by concentration of 1-OHP also we investigated removal efficiency by air cleaner for $PM_{10},\;NO_2$, and 1-OHP that were 28.5\%,\;27.4\%,\;and\;42.1\%$ respectively. Concentration of$PM_{10},\;NO_2$, and 1-OHP were $19.02\pm18.14{\mu}g/m^3,\;8.66\pm3.06ppb,\;and\;0.19\pm0.18{\mu}g/g$, creatinine when air cleaner was no worked. The concentration for $PM_{10},\;NO_2$. and 1-OHP were $13.60\pm10.79{\mu}g/m^3,\; 6.29\pm2.71ppb,\;and\;0.11\pm0.10{\mu}g/g$ creatinine, respectively. It was significant statistically. Therefore, it is considered using the air cleaner to remove the partial pollutants in indoor environment and is positive effect for health.

Properties of Cement Matrix using Carbon Black (카본블랙을 혼입한 시멘트 경화체의 특성)

  • Lee, Jeon-Ho;Lee, Chang-Woo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.217-218
    • /
    • 2021
  • With the prolonged Covid-19 epidemic, movement restrictions such as social distancing are prolonged, and as people stay indoors for a longer time, interest in indoor air pollution is increasing. Indoor air quality is not easily purified unlike outdoors. Among indoor building materials, paints and flooring contain formaldehyde that causes sick house syndrome and VOCs that contain carcinogenicity and harmfulness. For modern people who spend a lot of time living indoors for more than an hour, the occurrence of these harmful substances can be said to be fatal. In response to these risks, in July 2019, the government reinforced the standards for indoor air quality to protect the public's health by raising the detection standards for fine dust, ultrafine dust, and formaldehyde in indoor multi-use facilities. People use machines such as air purifiers to improve indoor air quality, or make efforts such as periodic ventilation. In order to reduce or support these other ancillary efforts more effectively, to reduce the generation of pollutants in the building itself, or to adsorb or purify pollutants in the air, use carbon black as an admixture to make a cement hardened body, and to grasp basic physical properties and adsorption capacity. And the result is as follows. As a result of the experiment to determine the appropriate amount of carbon black, it was confirmed that the more the amount of carbon black was added, the better it was in the formaldehyde emission test, but the tendency was not clear when measuring the flexural strength, so a further experiment to improve this is needed.

  • PDF

Impact of Indoor Plants on Indoor Air Quality and Occupational Health in Newly Built Public Building Offices - Focusing on Allergic Conjunctivitis and Stress-related Symptom Questionnaires - (신축건물 사무실내 식물 적용의 실내 공기질 및 재실자 건강영향 평가 - 알레르기 비결막염 및 스트레스 관련 증상설문을 중심으로 -)

  • Lee, Yong Won;Lim, Young Wook;Kim, Kwang-Jin;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.4
    • /
    • pp.334-348
    • /
    • 2017
  • Objectives: We investigated the impacts of indoor plants on indoor air quality and occupational health, focusing on allergic rhinconjunctivitis and stress among employees in new office buildings. Methods: A total of 34 employees working at new public office buildings were enrolled as subjects (n=17, with indoor plants) and as a control (n=17) group. Before and after introducing indoor plants for three months, indoor air quality measurements including VOCs and aldehydes and questionnaires on sick building syndrome, AR symptoms (ARIA based), stress (DASS 42, KOSS, and SACL), and indoor characteristics were performed and statistically analysed. Results: Among the 34 enrolled subjects, 19 were included in the probable AR subject group (subjects with indoor plants, n=8, control n=11) and completed all questionnaires. Statistical analyses were done for total, AR subject groups, and controls. As a result, it was confirmed that major indoor air pollutants decreased after the introduction of indoor plants (p<0.5). Among major symptoms of allergic rhinoconjunctivitis, watery rhinorrhea, nasal stuffiness, and nasal itching indexes decreased (p<0.5, respectively). A decrease was noted in some areas of work-related stress indexes (mainly KOSS) among the subject group (total and AR) and a decrease of indoor environmental attractiveness among the control group (total and AR) (p<0.5, for all). Conclusions: Indoor plants may help reduce indoor air pollutants and decrease AR symptoms and work-related stress of employees in newly built office buildings. Various further follow-up studies on the mechanism of environmental, physical, and emotional influences and utilization of indoor plants in association with allergic diseases will be needed.

Assessment of Conscious Coginition Degree and Survey on the Indoor Air Quality at a public School in Seoul (서울시 일부 학교의 실내 공기질 조사 및 인식도 평가)

  • Sohn, Jong-Ryeul;Byeon, Sang-Hoon;Kim, Young-Whan;Kim, Jong-Hyeok;Cho, Yun-Su;Lee, Jae-Young;Park, Youn-Ju
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.100-109
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and schools has been concern of people, scientists and related the public. And so in Seoul has recognized the healthy effect related to IAQ in schools. Therefore, the objective of this study reported in this article were to measure and compare the perception of IAQ of selected air pollutants at three different schools in Seoul. We performed a questionnaire survey of 400 students about their awareness for the importance of IAQ in our school. And we measured the IAQ of 3 schools considering as site region, construction year and studying level. The indoor air pollutants and parameters such as temperature, relative humidity, respirable particulate matter(PM10), formaldehyde(HCHO), total bacteria counts(TBC), carbon dioxide(CO$_2$), and noise were monitored in indoors. In results, all most response of occupant has recognized the awareness of IAQ at schools. The PMIO, TBC and Noise level of all schools were higher than the standard of the public 150 ${mu}$g/m$^3$ and 500CFU/m$^3$, the level formaldehyde(HCHO) was below 0.1 ppm of the healthy guideline of Korea And the concentration of CO$_2$ were investigated below 1,000 ppm of the standard implying ventilation in 2 schools except for 1 school(c school). Finally, the control of most important pollutants of IAQ in school were PM10, TBC and Noise. Therefore, it can be concluded that the indoor air quality of selected 3 schools studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems in schools, and all member relating school need to be effort to reduce the exposure of sources to undesirable indoor pollutants such as Particlate and Noise.

A Health Performance Evaluation Model of Building Indoor Air Quality (실내공기질의 건강성능 평가모델 연구)

  • ZHENG, QI;Lee, Dong-Hoon;Choi, Jae Hwi;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.3-10
    • /
    • 2010
  • As indoor air quality directly affects health and comforts of the residents, researchers from different countries have continued to explore criteria by which indoor air quality can be indicated in a scientific and quantitative manner over the past several decades. However, there are many possibilities that can deteriorate indoor air quality. Due to the uncertainty of influence factors, it is quite difficult to develop a correct evaluation model and quantitative method. Furthermore, the effects from the indoor air pollutants have different levels, leading to the difficulties to apply the regular standard. This study aims to propose evaluation criteria by using the FD-AHP analysis. Obtained findings will be beneficial to construct apartment buildings, commercial buildings and others health performance evaluation framework.

Properties of Adsorption Matrix for Improving Indoor Air Quality using Cork (코르크를 활용한 실내공기질 개선용 흡착 경화체의 특성)

  • Kim, Yeon-Ho;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.56-57
    • /
    • 2019
  • Recently, the risk of fine dust is emerging in Korea. According to the OECD report, the incidence of hospitalization and mortality from lung disease is increased, and the incidence of lung cancer and mortality from ischemic heart disease with prolonged exposure are increased. In addition, indoor air quality has become an important factor affecting the human body as indoor life has increased due to the Industrial Revolution. Air pollutants that cause indoor air deterioration typically include particulate dusts as described above, formaldehyde and VOCs released in gaseous form from adhesive wood products used in building materials and furniture. May cause breathing problems. In this study, we analyzed the properties of adsorption matrix for improving indoor air quality using cork.

  • PDF

Exposure Assessments for Children in Homes and in Daycare Centers to NO2, PMs and Black Carbon

  • Lee, Jae Young;Kim, Changhyeok;Kim, Jongbum;Ryu, Sung Hee;Bae, Gwi-Nam
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.204-214
    • /
    • 2018
  • Indoor air quality was investigated in homes and daycares located in areas with heavy traffic in Seoul, South Korea from November 2013 to January 2014. Indoor and outdoor air quality measurements were collected for 48 hours in four children's homes and daycare centers. The I/O ratio (Indoor to outdoor ratio) for each major air pollutant ($NO_2$, black carbon, $PM_{10}$, and $PM_{2.5}$) was calculated, and $NO_2$ and $PM_{10}$ concentration profiles were analyzed based on indoor activity diaries recorded during the 48 hours. Most I/O ratios for $NO_2$, black carbon, $PM_{10}$, and $PM_{2.5}$ at daycare centers were less than one. At homes, I/O ratios for black carbon, $PM_{10}$, and $PM_{2.5}$ were less than one; however, most I/O ratios for $NO_2$ were greater than one due to the usage of gas stoves. The children's exposure to indoor air pollutants was calculated using a time-weighted average exposure method, and the daily intake level for each pollutant was determined.

The Assessment of Survey on the Indoor Air Quality at Schools in Korea (국내 일부학교 건축물의 실내공기질 평가)

  • Sohn Jong-Ryeul;Roh Young-Man;Son Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.