간접냉각방식을 이용한 열원이 부착된 채널내의 열전달 촉진에 관한 연구 (The study on heat transfer enhancement using indirect cooling system in the channel with heat source)

  • 김광추;박만흥;윤준규
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.321-331
    • /
    • 1999
  • A numerical study is carried out for increasing heat removal using indirect cooling system. Computation is performed for nine cases as variation of flow condition in the lower channel. As the result of this study, water is more effective than air at the same pressure loss in spite of the lower inlet velocity. In channel configuration, the vertical channel is more effective than horizontal channel because of the buoyancy effect. Under the condition that heat generation is the same, counter flow effectively decreases the temperature difference among blocks. Parallel flow is more effective than counter flow when average temperature of all blocks is considered. In the case of installing obstacles in the lower channel, it is desirable to install obstacles in the bottom of lower channel. Heat transfer rate increases as the height of obstacles increases.

  • PDF

간접식 증발냉각장치의 성능예측과 에너지절약에 관한 연구 (Study on Performance Prediction and Energy Saving of Indirect Evaporative Cooling System)

  • 유성연;김태호;김명호
    • 대한기계학회논문집B
    • /
    • 제39권9호
    • /
    • pp.743-749
    • /
    • 2015
  • 본 연구의 목적은 간접식 증발냉각 장치의 성능을 예측하고, 장치를 공기조화기의 배기열 회수에 적용하였을 경우의 에너지 절약효과를 분석하는 것이다. 플라스틱 열교환기를 사용한 간접식 증발냉각장치의 성능 상관식을 여러가지 조건에서 얻어진 실험 데이터로부터 구하였으며, 이 상관식을 이용하여 환기와 외기의 조건을 변화시켜가면서 장치의 성능변화를 예측하였다. 또한 간접식 증발냉각장치의 배기열 회수에 의한 에너지 절약효과를 우리나라 몇개 도시의 표준기상데이터를 사용하여 분석하였다. 여름철 배기열 회수를 위한 현열냉각장치의 사용율은 평균 44.3%이며 증발냉각장치의 사용율은 96.7% 이다. 증발냉각장치의 배기열 회수에 의한 에너지 절약은 현열냉각장치에 비해서 훨씬 높으며, 서울의 경우 약 3.89 배로 나타났다.

간접냉각시스템을 이용한 인코넬 718소재의 가공성 평가 (Machinability Evaluation of Inconel 718 Material Using Indirect Cooling System)

  • 김진형;이여울;박성환;이동진;강명창
    • 한국기계가공학회지
    • /
    • 제18권2호
    • /
    • pp.96-101
    • /
    • 2019
  • This paper presents a machinability evaluation of Inconel 718 material when using a new uniform-temperature indirect cooling method that incorporates constant-pressure liquid nitrogen (LN2). The flank wear of a TiAlN coated tool used with this indirect cooling system was much lower than that of the tool used with dry machining under all machining conditions. Also, the surface roughness resulting from machining with this indirect method was far less than that of a dry machined surface after the same cutting time. Reduced heat generation and uniform temperature in turning operations play important roles in tool life and surface quality.

다수의 부구간으로 나누어지는 트로프간 접수냉 전력케이불의 열해석에 관한 연구 (A Study on the Thermal Analysis of Indirect Water Cooled Power Cables Laid within Trough devided into Several Sub-Sections)

  • 문영현;김백;이태식
    • 대한전기학회논문지
    • /
    • 제41권7호
    • /
    • pp.703-711
    • /
    • 1992
  • As the underground area of the metropolitan becomes denser recently, an introduction of forced cooling system is under study to maximize the carrying capacity of existing cables in tunnels. Indirect water cooling system laid within trough will probably be adopted for the next 345KV class underground power cables in this country. The system covers a distance of 1.5-3.0Km for one water cooling interval and one water cooling interval is composed of several sub-sections that have different thermal analysis conditions. Thus the distribution of temperature in each sub-section is described by different conditions in general. In this paper a method that can accurately match the temperature of the coolant in the boundary between sub-sections has been suggested. An algorithm to find the temperature distributions effectively in the thermal system has also been presented. A computer program using this method has been tested in a smaple system and the results have shown the usefulness of this program.

  • PDF

냉이온수기 냉각시스템에 관한 열유동 해석 (Thermal-flow Analysis of the Cooling System in the Medicated Water Electrolysis Apparatus)

  • 전성오;이상준;이종철;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제14권3호
    • /
    • pp.33-38
    • /
    • 2011
  • Medicated water electrolysis apparatus, which electrolyzes water into acidic water and alkaline water, was in the spotlight as becoming known the effect of alkaline water. It is known as good for health as removing active oxygen in the human's body and promoting digestion. But, the customers could not get that desired water temperature because these apparatuses are directly connected with a water pipe. So, the cooling system was developed for controlling the temperature of the alkaline water. One of the typical way is to store water in water tank and control the temperature. But, in this way, storing water can be polluted impurities coming from outside. For protecting this pollution, the cooling system based on indirect heat exchange method through phase change between water and ice was developed. In this study, we have calculated efficiency of the cooling system with phase change by experiment and commercial CFD(Computational Fluid Dynamics) code, ANSYS CFX. To consider the effect of latent heat that is generated by melting ice, we have simulated two phase numerical analyses used enthalpy method and found the temperature, velocity, and ice mass distribution for calculating the efficiency of cooling. From the results of numerical analysis, we have obtained the relationship between the cooling efficiency and each design factor.

서랍식 김치냉장고의 최적 유로 설계를 위한 유동특성에 관한 연구 (A study on flow characteristic of a stand type Kimchi refrigerator for optimum design of air flow passage)

  • 한호윤;정호윤;박영규;최윤환;이연원
    • 동력기계공학회지
    • /
    • 제15권5호
    • /
    • pp.37-42
    • /
    • 2011
  • The normal cooling system of a refrigerator is applied to indirect a cooling methods. But the Kimchi refrigerator is applied to direct the cooling method. Recently when the model was applied to both direct and indirect the cooling methods, the improvement was considerable. With the development of the living standards in Korea, there has been more sensitive dissatisfaction about the taste and the smell of Kimchi. In order to solve these kinds, there is a need to systematic and scientific approach. Based on these, the purpose of this study is to optimize design for improve the storage period of Kimchi refrigerator. In this research, we concentrate on the temperature change and heat transfer characteristics of interior parts of the Kimchi refrigerator due to control cycle of temperature and flow phenomenon of cooling air.

이산화탄소를 이용한 간접 냉장시스템의 실험적 연구 (Experimental Study of An Indirect-Refrigeration System with Carbon Dioxide)

  • 김윤섭;백원근;윤린
    • 설비공학논문집
    • /
    • 제28권5호
    • /
    • pp.202-207
    • /
    • 2016
  • Experimental studies for an indirect R404A-$CO_2$ refrigeration system and a direct R404A refrigeration system were conducted. The configurations of the indirect R404A-$CO_2$ refrigeration system are a R404A refrigeration system as a top cycle and a circulating $CO_2$ system as a bottom cycle. The direct R404A system was modified from indirect R404A-$CO_2$ refrigeration system by removing circuit for $CO_2$ circulation. Various tests for both systems were conducted by changing load side brine temperature from 0 to 5 and $10^{\circ}C$ with cooling brine temperatures for R404A system at 15, 20, or $25^{\circ}C$. The indirect R404A-$CO_2$ refrigeration system showed the highest COP when load side brine temperature was at $10^{\circ}C$ in the evaporator and at cooling brine temperature of $15^{\circ}C$. The COP of 3.04 under that condition was the highest. This indirect R404A-$CO_2$ refrigeration system showed 9.02% higher COP than the direct R404A system that had increased pipeline length of 15 m, which simulated actual installation in a supermarket.

에너지 절감형 염색기용 직접냉각수세장치에 대한 연구 (A Study on Direct Cooling and Washing Machine for Energy Saving-Type Dyeing Machine)

  • 한승철;김진호;김제훈;이성규
    • 한국산학기술학회논문지
    • /
    • 제13권2호
    • /
    • pp.485-491
    • /
    • 2012
  • 최근 국내 섬유산업의 생산량이 증가함에 따라 섬유산업에서 에너지 소비는 계속 증가되고 있는 실정이다. 기존의 염색기는 고온 고압의 특성을 가지고 있기 때문에 염색 후 냉각을 하기 위하여 열교환기를 통한 간접냉각방식을 채택하고 있다. 이러한 간접냉각방식은 물의 소모량이 많으며 작업 시간 또한 오래 걸리는 문제점이 있고 냉각시 염액의 고착으로 인해 냉각 후 환원세정 및 수세를 수차례 하므로 에너지가 많이 소비된다. 따라서 본 논문에서는 고온 고압 액류 염색기의 열교환기에 의한 간접냉각방식을 염색기내에 냉수를 직접 공급하는 직접냉각방식으로 대체하기 위한 장치를 개발하여 기존의 염색기에 적용하여 냉각과 동시에 환원세정공정을 생략하고 수세공정을 단축시키면서 전공정을 마무리함으로써 전체 작업공정을 줄이고 에너지 소비를 절감하는 등의 생산성을 획기적으로 향상시킬 수 있는 직접냉각수세장치를 제안하며, 시제작품을 제작하고, 실제 염색기에 적용하여 기존의 간접 냉각 방식의 염색기와 성능, 자원 및 에너지 절감율을 비교하였다. 또한 시제작품을 적용한 염색기의 염색성 실험을 하였다.

리튬이온 배터리 방전 시 발열 특성 및 냉각 실험과 유한요소 해석 (Thermal Characteristics and Cooling Experiments and Analysis of Finite Elements in the Discharge of Lithium-Ion Batteries)

  • 김석일;강신유
    • 산업기술연구
    • /
    • 제43권1호
    • /
    • pp.15-23
    • /
    • 2023
  • Lithium-ion batteries are predominantly employed in electric vehicles and energy storage devices, offering the advantage of high energy density. However, they are susceptible to efficiency degradation when operated at high temperatures due to their sensitivity to the external environment. In this study, we conducted experiments using an indirect cooling method to prevent thermal runaway and explosions in lithium-ion batteries. The results were validated by comparing them with heat transfer simulations conducted through a commercial finite element analysis program. The experiments included single-cell exothermic tests and cooling experiments on a battery pack with 10 cells connected in series, utilizing 21700 lithium-ion batteries. To block external temperature influences, the experimental environment featured an extrusion method insulation in the environmental chamber. The cooling system, suitable for indirect cooling, was constructed with copper tubes and pins. The heat transfer analysis began by presenting a single-cell heating model using commercial software, which was then employed to analyze the heating and cooling of the battery pack.

식각 공정용 냉각시스템에서의 직접 냉각 방식과 간접 냉각 방식에 관한 연구 (A Study on Direct Cooling and Indirect Cooling in Etching Process Cooling System)

  • 장경민;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제17권3호
    • /
    • pp.100-103
    • /
    • 2018
  • Due to the plasma applied from the outside, which acts as an etchant during the etching process, considerable heat is transferred to the wafer and a separate cooling process is performed to effectively remove the heat after the process. In this case, a direct cooling method using a refrigerant is suitable for cooling through effective heat exchange. The direct cooling method using the refrigerant using the latent heat exchange is superior to the cooling method using the sensible heat exchange. Therefore, in this paper, AMESim is used to design a direct refrigerant cooling system using latent heat exchange simulator was built.The constructed simulator is reliable compared with the actual experimental results. It is expected that this simulator will help to design and search for optimal process conditions.