• 제목/요약/키워드: Indicated power

검색결과 994건 처리시간 0.026초

전력계통 안정성 향상을 위한 발전기 제어계 특성시험 및 모델링 (Generator Testing and Model Validation for Thermal Plant)

  • 차승태;김용학;오세일;최준호;신정훈;심응보;곽노홍;손현일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.473-474
    • /
    • 2007
  • The Jeju power grid experienced several major power disturbances over the last decade. The postmortem studies of the incidents indicated that some of the generating units did not respond as predicted by system analysis & studies. Consequently, the Korean Power Exchange (KPX) mandated that all units (generators, excitation, governor and turbine systems) in the Korean network greater than or equal to 20MVA be tested to verify the generator reactive power limits as well as the dynamic model data being used for system studies. This paper presents field experiences of the authors in testing and modeling of steam turbines and their associated governors during the generator and model validation.

  • PDF

원자력발전소의 급수유량 측정에 대한 초음파유량계의 적용성 연구 (A Study on Applicability of Ultrasonic Flowmeter to Feedwater Flow Measurements in Nuclear Power Plants)

  • 유성식;박종호
    • 한국유체기계학회 논문집
    • /
    • 제6권1호
    • /
    • pp.57-65
    • /
    • 2003
  • The measurement uncertainties of an ultrasonic flowmeter were analyzed to evaluate its applicability to the measurement of the steam generator feedwater flow-rate in a nuclear power plant. The analyses of measurement uncertainties of a reactor power were also performed with the analyses of feedwater flow measurement uncertainties. Two ultrasonic flowmeters based on a cross-correlation technique and a transit time method were used in this study. The ultrasonic flowmeters were installed on a feedwater pipe line of a typical 1000 MWe Korea-standardized nuclear power plant to take the necessary data. The results have shown that the measurement uncertainties of the ultrasonic flowmeters are adequately smaller than those or a venturi meter. The research has also indicated that the measurement uncertainties of the reactor power based on the ultrasonic flowmeter uncertainties are sufficiently bounded by the uncertainty range usually assumed in nuclear safety analyses.

GaAs PIN Diode를 이용한 MMIC 리미터 설계 및 제작 (Design and Fabrication of MMIC Limiter with GaAs PIU Diode)

  • 정명득;강현일
    • 한국전자파학회논문지
    • /
    • 제14권6호
    • /
    • pp.625-629
    • /
    • 2003
  • GaAs PIN 다이오드를 이용하여 저손실 고출력 MMIC 리미터를 설계하고 제작하였다. 고전력 수용 능력을 증가시키기 위하여 새로운 GaAs PIN 다이오드 에피구조를 제안하였다. 2종류의 리미터 회로를 설계하고 그리미팅 전력을 측정하였다. 측정결과에서 리미팅 전력은 설계회로 토폴로지에 따라 달라졌다. 제작된 2단 리미터의 리미팅 전력은 14 ㎓에서 각각 17 ㏈m과 23 ㏈m으로 측정되었다.

뇌파 상대 스펙트럼의 숙련도 평가 척도로의 이용 가능성에 대한 연구 (A Study on Applicability of EEG Spectral Relative Power as a Measure of Expertise Level)

  • 옥동민;박희석
    • 대한인간공학회지
    • /
    • 제29권5호
    • /
    • pp.741-750
    • /
    • 2010
  • The objective of this paper is to study if the EEG spectral relative power would be a reasonable measure of expertise level. EEG electrodes were placed on the locations of Fp1, Fp2, F3, F4, T3, T4, O1, O2 while 5 subjects were playing 4 kinds of game on PC. EEG spectral relative power was significantly related with expertise level on the locations of Fp1, T3, T4, O1, O2. And the results showed that the $\theta$ and $\alpha$ activities were decreased, while $\beta$ and $\gamma$ activities were increased. The results indicated that the EEG spectral relative power would be applicable as a quantitative measure of expertise level.

육상 디젤 발전소용 저속 2행정 디젤엔진의 종진동에 관한 연구 (A study of Axial Vibration of Two Stroke Low Speed Diesel Engine On the Diesel Power Plant)

  • 이돈출;고재용;유정대
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1816-1822
    • /
    • 2000
  • The maximum and mean indicated pressure of two stroke low speed diesel engine has been continuously increased with a view of increasing engine power and also reducing fuel consumption. As a result, axial excitation has been highed comparing to that of the previous and so in standard axial vibration damper is applied to all two stroke low speed diesel engine at the free end of crankshaft. Though many studies were carried out for marine use, few has been made for diesel power plant because there was little demand for power plant. Nowadays, diesel engine is much to be used for many benefits and so in this paper, the optimum design of axial vibration on the 65 MW diesel power plant with 9K80MC-S engine was carried out. And the axial-torsional coupled vibration of this shafting system is identified by theoretical analysis and vibration measurement.

  • PDF

구조용 데크 플레이트 연속 슬래브의 휨거동에 관한 실험적 연구 (An Experimental Study on the Flexural Behavior of Structural Deck Plate Continuous Slabs)

  • 김영호;박영석;박성우;고영우;양근혁;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.202-205
    • /
    • 2003
  • The purpose of this experimental study is to understand the flexural Behavior of structural deck plate continuous slabs (power deck plate slabs). The main variables considered in this test are thickness of the slab and the deck plate. Five specimens that have length of 600cm and width of 60cm were manufactured. Test results indicated that the ultimate flexural strength of power deck plate slabs was conservative compared to ACI flexural provisions. But, suitable arrangement of bar of top reinforcement is needed for crack control.

  • PDF

The Effect of External DC Electric Field on the Atmospheric Corrosion Behaviour of Zinc under a Thin Electrolyte Layer

  • Liang, Qinqin;YanYang, YanYang;Zhang, Junxi;Yuan, Xujie;Chen, Qimeng
    • Corrosion Science and Technology
    • /
    • 제17권2호
    • /
    • pp.54-59
    • /
    • 2018
  • The effect of external DC electric field on atmospheric corrosion behavior of zinc under a thin electrolyte layer (TEL) was investigated by measuring open circuit potential (OCP), cathodic polarization curve, and electrochemical impedance spectroscopy (EIS). Results of OCP vs. time curves indicated that the application of external DC electric field resulted in a negative shift of OCP of zinc. Results of cathodic polarization curves measurement and EIS measurement showed that the reduction current of oxygen increased while charge transfer resistance ($R_{ct}$) decreased under the external DC electric field. Variation of OCP negative shift, reduction current of oxygen, and $R_{ct}$ increase with increasing of external DC electric field strength as well as the effect of external DC electric field on double-layer structure in the electrode/electrolyte interface and ions distribution in thin electrolyte layer were analyzed. All results showed that the external DC electric field could accelerate the corrosion of zinc under a thin electrolyte layer.

New Control Strategy for Three-Phase Grid-Connected LCL Inverters without a Phase-Locked Loop

  • Zhou, Lin;Yang, Ming;Liu, Qiang;Guo, Ke
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.487-496
    • /
    • 2013
  • The three-phase synchronous reference frame phase-locked loop (SRF-PLL) is widely used for synchronization applications in power systems. In this paper, a new control strategy for three-phase grid-connected LCL inverters without a PLL is presented. According to the new strategy, a current reference can be generated by using the instantaneous power control scheme and the proposed positive-sequence voltage detector. Through theoretical analysis, it is indicated that a high-quality grid current can be produced by introducing the new control strategy. In addition, a kind of independent control for reactive power can be achieved under unbalanced and distorted grid conditions. Finally, the excellent performance of the proposed control strategy is validated by means of simulation and experimental results.

The Improvement of Junction Box Within Photovoltaic Power System

  • Sun, Ki-Ju;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권6호
    • /
    • pp.359-362
    • /
    • 2016
  • In the PV (Photovoltaic) power system, a junction box collects the DC voltage generated from the PV module and transfers it to the PCS (power conditioning system). The junction box prevents damage caused by the voltage difference between the serially connected PV modules and provides convenience while repairing or inspecting the PV array. In addition, the junction box uses the diode to protect modules from the inverse current when the PV power system and electric power system are connected for use. However, by using the reverse blocking diode, heat is generated within the junction box while generating electric power, which decreases the generating efficiency, and causes short circuit and electric leakage. In this research, based on the purpose of improving the performance of the PV module by decreasing the heat generation within the junction box, a junction box with a built-in bypass circuit was designed/manufactured so that a certain capacity of current generated from the PV module does not run through the reverse blocking diode. The manufactured junction box was used to compare the electric power and heating power generated when the circuit was in the bypass/non-bypass modes. It was confirmed that the electric power loss and heat generation indicated a decrease when the circuit was in the bypass mode.

작업난이도 변화가 인간과오 관련 뇌파 특성에 미치는 영향 (Influence of Work Difficulty Variation on EEG Characteristics Related with Human Errors)

  • 임현교
    • 한국안전학회지
    • /
    • 제25권3호
    • /
    • pp.123-130
    • /
    • 2010
  • Electroencephalogram(EEG) would be the most objective psychophysiological research technique on human errors though few research has been taken yet. This study aimed to get characteristics of human error while committing simple Odd-Ball tasks by utilizing the power spectrum technique of EEG data. Each experiment was composed of 3 tasks with different rules, and 8 young undergraduate students participated in this study as paid subjects. The result showed in the affirmative that subject and the interaction of subject and task factors were statistically significant on variation of $\alpha$ band power $P_{\alpha/(\alpha+\beta+\theta)}$ and $\beta$ band power $P_{\beta/(\alpha+\beta+\theta)}$, and that the former increasing in backward direction to Pz reflects compatibility whereas the latter increasing in forward direction to Fz reflects familiarity. Therefore it was coucluded that, since task 2 carried out in the present research requiring decoding process would be more difficult to human beings than the task merely requiring psychological recall process, task 1 and task 3 were classified into a homogenious group excluding task 2, and the ratio $\alpha$ band power to $\beta$ band power indicated enormous increase of $\alpha$ band power relative to $\beta$ band power in the cases of contra-lateral errors, especially in task 2.