• 제목/요약/키워드: Independent Protection Layer

검색결과 8건 처리시간 0.022초

A Fast and Scalable Inter-Domain MPLS Protection Mechanism

  • Huang, Chang-Cheng;Messier, Donald
    • Journal of Communications and Networks
    • /
    • 제6권1호
    • /
    • pp.60-67
    • /
    • 2004
  • With the fast growth of Internet and a new widespread interest in optical networks, the unparalleled potential of Multi-Protocol Label Switching (MPLS) is leading to further research and development efforts. One of those areas of research is Path Protection Mechanism. It is widely accepted that layer three protection and recovery mechanisms are too slow for today’s reliability requirements. Failure recovery latencies ranging from several seconds to minutes, for layer three routing protocols, have been widely reported. For this reason, a recovery mechanism at the MPLS layer capable of recovering from failed paths in 10’s of milliseconds has been sought. In light of this, several MPLS based protection mechanisms have been proposed, such as end-to-end path protection and local repair mechanism. Those mechanisms are designed for intra-domain recoveries and little or no attention has been given to the case of non-homogenous independent inter-domains. This paper presents a novel solution for the setup and maintenance of independent protection mechanisms within individual domains and merged at the domain boundaries. This innovative solution offers significant advantages including fast recovery across multiple nonhomogeneous domains and high scalability. Detailed setup and operation procedures are described. Finally, simulation results using OPNET are presented showing recovery times of a few milliseconds.

LOPA 및 SIF기법에 의한 LPG 인수기지의 안전성향상에 대한 연구 (Safety Enhancement of LPG Terminal by LOPA & SIF Method)

  • 이일재;김래현
    • Korean Chemical Engineering Research
    • /
    • 제53권4호
    • /
    • pp.431-439
    • /
    • 2015
  • 본 연구에서는 LPG(Liquefied Petroleum Gas) 인수기지에 대해 HAZOP(Hazard and Operability), LOPA(Layer of Protection Analysis) 및 SIL(Safety Integrity Level) 위험성 평가기법을 적용하여, 국내 LPG 인수기지 중 사고발생시 피해영향이 가장 큰 부탄 및 프로판 저장탱크를 중심으로, 사고위험성을 감소시킬 수 있는 방안을 고찰하였다. HAZOP 기법을 통해 잠재위험성을 분석하여 사고시나리오를 도출하고, 사고피해영향이 큰 시나리오를 선정하여 LOPA를 분석하였다. LOPA 분석시에는 해당시나리오에 대한 IPL(Independent Protection Layer)을 분석하여 완화된 결과의 빈도를 도출한 후, 설정된 위험성 허용기준($1.0{\times}10^{-05}$/년)에 대한 충족여부를 판단하였다. LOPA의 독립방호계층으로서 SIF(Safety Instrumented Functions)의 경제성을 분석하여 SIF가 현장의 특성에 맞는 IPL이 되도록 개선안을 제시하였다. 또한, 독립방호계층으로서 해당공정에 사용된 SIF의 수준을 분석해보고, SIF의 수준에 따라 공정의 사고발생빈도가 어느 정도 변화하는지를 당해 공정에서 도출된 사고시나리오를 중심으로 연구하였다.

Characteristics of Interface States in One-dimensional Composite Photonic Structures

  • Zhang, Qingyue;Mao, Weitao;Zhao, Qiuling;Wang, Maorong;Wang, Xia;Tam, Wing Yim
    • Current Optics and Photonics
    • /
    • 제6권3호
    • /
    • pp.270-281
    • /
    • 2022
  • Based on the transfer-matrix method (TMM), we report the characteristics of the interface states in one-dimensional (1D) composite structures consisting of two photonic crystals (PCs) composed of binary dielectrics A and B, with unit-cell configurations ABA (PC I) and BAB (PC II). The dependence of the interface states on the number of unit cells N and the boundary factor x are displayed. It is verified that the interface states are independent of N when the PC has inversion symmetry (x = 0.5). Besides, the composite structures support the formation of interface states independent of the PC symmetry, except that the positions of the interface states will be varied within the photonic band gaps. Moreover, the robustness of the interface states against nonuniformities is investigated by adding Gaussian noise to the layer thickness. In the case of inversion symmetry (x = 0.5) the most robust interface states are achieved, while for the other cases (x ≠ 0.5) interface states decay linearly with position inside the band gap. This work could shed light on the development of robust photonic devices.

지오콤을 이용한 사면녹화공법의 현장적용 사례 (Case Study of Slope Protection Method using GeoComb)

  • 오영인;김성환;유중조;심진섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.974-979
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of vegetation on the cutting slope applied by vegetation system in the whole land. The engineering characteristics of slopes were investigated using the face mapping and physical tests. From the statistical methods, a relationship between a geologic stratum and degree of covering was independent. Therefore, the afforestation of slope was affected more by condition of vegetation as direction and opening of joints, and a topsoil state than by conventional classification of layer. It was concluded that the adjustable vegetation on the slope considering condition of geometric shape of slope, joint data and spontaneous type could make useful early afforestation.

  • PDF

A Study on the Risk Management Tools against Infectious Diseases in the Port-Utilizing Semi-Quantitative Bow-Tie Method

  • Lim, Kukhwan;Oh, Yong-Sik
    • 한국항해항만학회지
    • /
    • 제46권2호
    • /
    • pp.145-157
    • /
    • 2022
  • Due to the global epidemic of infectious diseases, it has become important for all industries to respond to the risk of infectious diseases. Ports in each country are also responding to the risk of infectious diseases, but the occurrence of infectious diseases in ports of various countries is causing a lot of damage to the logistics of ports. Korea is in the same situation, and cases of infectious diseases in ports are steadily being announced. Therefore, this paper conducted semi-quantitative Bow-Tie risk assessment by substituting measures to cope with infectious disease risks in Korean ports into actual cases of port infectious diseases in Korea, deriving improvements and suggesting directions. As a result, it was concluded that it was necessary to standardize some of the countermeasures against infectious diseases and develop more countermeasures.

다중 종속 고장상태를 갖는 공정시스템의 신뢰성 모델 (A Reliability Model of Process Systems with Multiple Dependent Failure States)

  • 최수형
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.37-41
    • /
    • 2018
  • Process safety technology has developed from qualitative methods such as HAZOP (hazard and operability study) to semi-quantitative methods such as LOPA (layer of protection analysis), and quantitative methods are actively studied these days. Quantitative risk assessment (QRA) is often based on fault tree analysis (FTA). FTA is efficient, but difficult to apply when failure events are not independent of each other. This problem can be avoided using a Markov process (MP). MP requires definition of all possible states, and thus, generally, is more complicated than FTA. A method is proposed in this work that uses an MP model and a Weibull distribution model in order to construct a reliability model for multiple dependent failures. As a case study, a pressure safety valve (PSV) is considered, for which there are three kinds of failure, i.e. open failure, close failure, and gas tight failure. According to recently reported inspection results, open failure and close failure are dependent on each other. A reliability model for a PSV group is proposed in this work that is to reproduce these results. It is expected that the application of the proposed method can be expanded to QRA of various systems that have partially dependent multiple failure states.

공연장 무대 화재 시 방화막과 강제 배연구가 객석으로의 연기 확산에 미치는 영향 (Effects of Fire Curtain and Forced Smoke Ventilation on Smoke Spread to Auditorium in Stage Fire of Theater)

  • 김재한;김동균;이치영
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.28-36
    • /
    • 2017
  • 본 논문에서는 공연장 무대 화재 시 객석으로의 연기 확산에 방화막 및 강제 배연구가 미치는 영향에 대하여 Fire Dynamics Simulator (FDS)를 이용하여 연구를 수행하였다. 폭 31 m, 깊이 34 m, 높이 32 m의 무대에 대하여, 10 MW의 열방출률과 화재성장속도가 fast인 화재를 적용하였다. 강제 배출량은 화재안전기준과 기존 연구를 토대로 설정하였으며, 방화막과 프로시니움 (Proscenium) 벽 사이 간격은 0 m, 0.5 m인 경우를 대상으로 하였다. 방화막과 프로시니움 벽이 완벽하게 밀착되어 있는 경우, 강제 배연구와는 상관없이 객석으로의 연기 확산은 일어나지 않았다. 방화막과 프로시니움 벽 사이의 간격이 0.5 m인 경우, 방화막이 없는 경우에 비해 무대 공간 내에서 연기층이 더욱 낮은 높이까지 하강하였으며, 이는 방화막에 의해 객석으로의 연기 확산이 방해받았기 때문이다. 한편, 동일한 방화막 조건에서, 강제 배연구가 있는 경우가 없는 경우에 비해 방화막과 프로시니움 벽 사이 간격을 통한 유출 질량유량이 작았다. 본 연구를 통하여 방화막과 강제 배연구가 공연장 무대 화재 시 객석으로의 연기 확산을 억제할 수 있는 효과적인 방법임을 확인하였다.

사고시나리오별 위험도 산정을 통한 적정 위험도 기준 설정 (Establishment of the Appropriate Risk Standard through the Risk Assessment of Accident Scenario)

  • 김건호;천영우;황용우;이익모;곽인호
    • 대한환경공학회지
    • /
    • 제39권2호
    • /
    • pp.74-81
    • /
    • 2017
  • 장외영향평가란 사업장에서 취급되는 유해화학물질이 누출되었을 시 사업장 외부로 미치는 위험도를 산정하는 것으로, 사고시나리오별 영향평가를 실시하여 사고시나리오별 위험도를 산정하고, 안전성 확보방안 등을 고려하여 사업장의 최종 위험도를 결정하게 된다. 사업장의 최종 위험도에 가장 큰 영향을 미치는 요인은 사고시나리오별 위험도로, 사업장에서는 사고시나리오별 위험도를 낮출 필요가 있다. 본 연구는 이 점에 착안하여 동일한 설비에 대하여 OGP/LOPA의 위험도 산정기법을 적용하여 사고시나리오별 위험도를 산정하고, 각 개시사건별 적용 가능한 완화장치를 검토하여 사고시나리오의 위험도 감소율을 산정하고, 위험도 산정기법별 적정 위험도 기준을 제시하고자 한다. 적용 가능한 모든 완화장치를 고려하여 사고시나리오의 안전성 향상도를 산정할 경우 OGP에 의한 위험도는 8.05E-04, LOPA에 의한 위험도는 1.00E-04로 분석되었으며, IPL 적용사례에 따라 완화장치를 적용한 경우의 위험도는 1.34E-02로 분석되어서, 완화장치를 적용하지 않은 경우의 LOPA 적용시에 비해 위험도가 33배 가량 낮아지는 것으로 나타났다. 완화장치 적용 수준에 따른 안전성 향상율을 비교 검토하여 장외영향평가 시 사업장의 적정 위험도 기준을 제시하였다. 본 연구결과에 따르면 LOPA를 적용한 사고시나리오의 적정 위험도 기준은 $10^{-2}$ 수준으로 나타났으나, 유사연구의 사고시나리오별 적정 위험도 기준은 $10^{-3}{\sim}10^{-4}$ 수준으로, LOPA를 적용하여 사고시나리오의 위험도를 산정하는 경우 허용 불가능한 수준으로 결정될 수 있다. 따라서 LOPA를 적용하는 경우 허용 가능한 위험도 수준을 만족하기 위해서는 완화장치 적용 원칙 외에 추가로 적용 가능한 모든 완화장치를 적용하여야 하며, OGP에 비해 LOPA를 적용하는 경우 위험도가 높게 산정되는 경향이 있으므로 위험도 기법별로 허용 가능한 위험도 수준을 다르게 설정해야 할 것으로 판단된다.