• Title/Summary/Keyword: Independent Protection Layer

Search Result 8, Processing Time 0.022 seconds

A Fast and Scalable Inter-Domain MPLS Protection Mechanism

  • Huang, Chang-Cheng;Messier, Donald
    • Journal of Communications and Networks
    • /
    • v.6 no.1
    • /
    • pp.60-67
    • /
    • 2004
  • With the fast growth of Internet and a new widespread interest in optical networks, the unparalleled potential of Multi-Protocol Label Switching (MPLS) is leading to further research and development efforts. One of those areas of research is Path Protection Mechanism. It is widely accepted that layer three protection and recovery mechanisms are too slow for today’s reliability requirements. Failure recovery latencies ranging from several seconds to minutes, for layer three routing protocols, have been widely reported. For this reason, a recovery mechanism at the MPLS layer capable of recovering from failed paths in 10’s of milliseconds has been sought. In light of this, several MPLS based protection mechanisms have been proposed, such as end-to-end path protection and local repair mechanism. Those mechanisms are designed for intra-domain recoveries and little or no attention has been given to the case of non-homogenous independent inter-domains. This paper presents a novel solution for the setup and maintenance of independent protection mechanisms within individual domains and merged at the domain boundaries. This innovative solution offers significant advantages including fast recovery across multiple nonhomogeneous domains and high scalability. Detailed setup and operation procedures are described. Finally, simulation results using OPNET are presented showing recovery times of a few milliseconds.

Safety Enhancement of LPG Terminal by LOPA & SIF Method (LOPA 및 SIF기법에 의한 LPG 인수기지의 안전성향상에 대한 연구)

  • Lee, Il Jae;Kim, Rae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.431-439
    • /
    • 2015
  • The methods which decrease the accident hazards of LPG(Liquefied Petroleum Gas) terminal on the basis of butane & propane storage tanks by applying HAZOP(Hazard and Operability), LOPA(Layer of Protection Analysis) and SIL(Safety Integrity Level) are suggested. The accident scenarios were derived by analyzing latent risks through the HAZOP. The scenarios which would have the big damage effect in accidents were selected and then LOPA was assessed by analyzing IPL(Independent Protection Layer) about the correspond accident scenarios. The improved methods were proposed on the basis of level of SIF(Safety Instrumented Functions) as a IPL considering satisfied condition of risk tolerance criteria($1.0{\times}10^{-05}/y$). In addition, The proposed IPLs were basis on the economic analysis. The effect of SIF as a IPL considering the changes of accident frequency was studied in case of the accident scenarios derived from the concerned process.

Characteristics of Interface States in One-dimensional Composite Photonic Structures

  • Zhang, Qingyue;Mao, Weitao;Zhao, Qiuling;Wang, Maorong;Wang, Xia;Tam, Wing Yim
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.270-281
    • /
    • 2022
  • Based on the transfer-matrix method (TMM), we report the characteristics of the interface states in one-dimensional (1D) composite structures consisting of two photonic crystals (PCs) composed of binary dielectrics A and B, with unit-cell configurations ABA (PC I) and BAB (PC II). The dependence of the interface states on the number of unit cells N and the boundary factor x are displayed. It is verified that the interface states are independent of N when the PC has inversion symmetry (x = 0.5). Besides, the composite structures support the formation of interface states independent of the PC symmetry, except that the positions of the interface states will be varied within the photonic band gaps. Moreover, the robustness of the interface states against nonuniformities is investigated by adding Gaussian noise to the layer thickness. In the case of inversion symmetry (x = 0.5) the most robust interface states are achieved, while for the other cases (x ≠ 0.5) interface states decay linearly with position inside the band gap. This work could shed light on the development of robust photonic devices.

Case Study of Slope Protection Method using GeoComb (지오콤을 이용한 사면녹화공법의 현장적용 사례)

  • Oh, Young-In;Kim, Sung-Hwan;Yuu, Jung-Jo;Shim, Jin-Seap
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.974-979
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of vegetation on the cutting slope applied by vegetation system in the whole land. The engineering characteristics of slopes were investigated using the face mapping and physical tests. From the statistical methods, a relationship between a geologic stratum and degree of covering was independent. Therefore, the afforestation of slope was affected more by condition of vegetation as direction and opening of joints, and a topsoil state than by conventional classification of layer. It was concluded that the adjustable vegetation on the slope considering condition of geometric shape of slope, joint data and spontaneous type could make useful early afforestation.

  • PDF

A Study on the Risk Management Tools against Infectious Diseases in the Port-Utilizing Semi-Quantitative Bow-Tie Method

  • Lim, Kukhwan;Oh, Yong-Sik
    • Journal of Navigation and Port Research
    • /
    • v.46 no.2
    • /
    • pp.145-157
    • /
    • 2022
  • Due to the global epidemic of infectious diseases, it has become important for all industries to respond to the risk of infectious diseases. Ports in each country are also responding to the risk of infectious diseases, but the occurrence of infectious diseases in ports of various countries is causing a lot of damage to the logistics of ports. Korea is in the same situation, and cases of infectious diseases in ports are steadily being announced. Therefore, this paper conducted semi-quantitative Bow-Tie risk assessment by substituting measures to cope with infectious disease risks in Korean ports into actual cases of port infectious diseases in Korea, deriving improvements and suggesting directions. As a result, it was concluded that it was necessary to standardize some of the countermeasures against infectious diseases and develop more countermeasures.

A Reliability Model of Process Systems with Multiple Dependent Failure States (다중 종속 고장상태를 갖는 공정시스템의 신뢰성 모델)

  • Choi, Soo Hyoung
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.37-41
    • /
    • 2018
  • Process safety technology has developed from qualitative methods such as HAZOP (hazard and operability study) to semi-quantitative methods such as LOPA (layer of protection analysis), and quantitative methods are actively studied these days. Quantitative risk assessment (QRA) is often based on fault tree analysis (FTA). FTA is efficient, but difficult to apply when failure events are not independent of each other. This problem can be avoided using a Markov process (MP). MP requires definition of all possible states, and thus, generally, is more complicated than FTA. A method is proposed in this work that uses an MP model and a Weibull distribution model in order to construct a reliability model for multiple dependent failures. As a case study, a pressure safety valve (PSV) is considered, for which there are three kinds of failure, i.e. open failure, close failure, and gas tight failure. According to recently reported inspection results, open failure and close failure are dependent on each other. A reliability model for a PSV group is proposed in this work that is to reproduce these results. It is expected that the application of the proposed method can be expanded to QRA of various systems that have partially dependent multiple failure states.

Effects of Fire Curtain and Forced Smoke Ventilation on Smoke Spread to Auditorium in Stage Fire of Theater (공연장 무대 화재 시 방화막과 강제 배연구가 객석으로의 연기 확산에 미치는 영향)

  • Kim, Jae Han;Kim, Duncan;Lee, Chi Young
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.28-36
    • /
    • 2017
  • In this work, the effects of fire curtain and forced smoke ventilation on smoke spread to auditorium in the stage fire of theater were investigated using the Fire Dynamics Simulator (FDS). For the stage of 31 m (Width)${\times}$34 m (Depth)${\times}$32 m (Height) in dimension, the fast growth fire condition with 10 MW of heat release rate was applied. The forced smoke ventilation was set based on the National Fire Safety Code (NFSC) and previous research. The gap distances between the fire curtain and proscenium wall was established to be 0 m and 0.5 m. When the fire curtain was attached completely to the proscenium wall without any gap, no smoke spread from the stage to the auditorium occurred, independent of forced smoke ventilation. When the gap distance between the fire curtain and proscenium wall was 0.5 m, the smoke layer in the stage descended to the lower height from the bottom than the case without the fire curtain, which was because the smoke spread to auditorium was impeded by the fire curtain. Under the same fire curtain condition, the case with the forced smoke ventilation led to decreasing the mass flow rate of outflow through the gap between the fire curtain and proscenium wall, as compared to the case without the forced smoke ventilation. Based on this study, it was confirmed that the fire curtain and forced smoke ventilation were the effective tools to hold down the smoke spread to the auditorium in the stage fire of theater.

Establishment of the Appropriate Risk Standard through the Risk Assessment of Accident Scenario (사고시나리오별 위험도 산정을 통한 적정 위험도 기준 설정)

  • Kim, Kun-Ho;Chun, Young-Woo;Hwang, Yong-Woo;Lee, Ik-Mo;Kwak, In-ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • An off-site consequence analysis is used to calculate the risks when hazardous chemicals that is being used on-site has been exposed off-site; the biggest factor that impacts the risk is the risks of accident scenarios. This study seeks to calculate risks according to accident scenarios by applying OGP/LOPA risk calculating methods for similar facilities, calculate risk reduction ratio by inspecting applicable IPL for incidents, and propose an appropriate risk standard for different risk calculating methods. Considering all applicable IPL when estimating the safety improvement of accident scenarios, the risk of OGP is 8.05E-04 and the risk of LOPA is 1.00E-04, According to the case of IPL, the risk is 1.34E-02. The optimal risk level for accident scenarios using LOPA was $10^{-2}$, but the appropriate risk criteria for accident scenarios in foreign similar studies were $10^{-3}{\sim}10^{-4}$, the risk of a scenario can be determined at an unacceptable level. When OGP is applied, it is analyzed as acceptable level, but in case of applying LOPA, all applicable IPL should be applied in order to satisfy the acceptable risk level. Compared to OGP, the risk is high when LOPA is applied. Therefore, the acceptable risk level should be set differently for each risk method.