• 제목/요약/키워드: In-phase/Out-phase

검색결과 4,164건 처리시간 0.037초

Salting-out Effects on the Partition of Proteins in Aqueous Two-phase Systems

  • KIM, CHAN-WHA;CHO KYUN RHA
    • Journal of Microbiology and Biotechnology
    • /
    • 제6권5호
    • /
    • pp.352-357
    • /
    • 1996
  • The partition of proteins in the salt-rich phase of polyethylene glycol (pEG)/salt aqueous two-phase systems is limited by the salting-out effects of salt. The logarithm of the concentration of proteins partitioned in the salt-rich phase decreases linearly with increases in the concentration of salt in the salt-rich phase (salting-out). Therefore, the partition of a given protein in the salt-rich phase of aqueous two-phase systems can be estimated from the salting-out constant. The slope of the solubility line (salting-out con-stant) for a given protein is determined by the type of salt in the two-phase systems.

  • PDF

변형률분할법에 의한 12Cr 단조강의 열피로 수명예측 (Thermal-mechanical Fatigue Life Prediction of 12Cr Forged Steel Using Strain Range Partitioning method)

  • 하정수;옹장우;고승기
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1192-1202
    • /
    • 1994
  • Fatigue behavior and life prediction were presented for thermal-mechanical and isothermal low cycle fatigue of 12Cr forged steel used for high temperature applications. In-phase and out-of-phase thermal-mechanical fatigue test at 350 to 600.deg. C and isothermal low cycle fatigue test at 600.deg. C were conducted using smooth cylindrical hollow specimen under strain-control with total strain ranges from 0.006 to 0.015. Cyclic softening behavior was observed regardless of thermal-mechanical and isothermal fatigue tests. The phase difference between temperature and strain in thermal-mechanical fatigue resulted in significantly shorter fatigue life for out-of-phase than for in-phase. The difference in fatigue lives was dependent upon the magnitudes of inelastic strain ranges and mean stresses. Increase in inelastic strain range showed a tendency of intergranular cracking and decrease in fatigue life, especially for out-of-phase thermal-mechanical fatigue. Thermal-mechanical fatigue life prediction was made by partitioning the strain ranges of the hysteresis loops and the results of isothermal low cycle fatigue tests which were performed under the combination of slow and fast strain rates. Predicted fatigue lives for out-of-phase using the strain range partitioning method showed an excellent agreement with the actual out-of-phase thermal-mechanical fatigue lives within a factor of 1.5. Conventional strain range partitioning method exhibited a poor accuracy in the prediction of in-phase thermal-mechanical fatigue lives, which was quite improved conservatively by a proposed strain range partitioning method.

Single-Phase Z-Source AC/AC Converter with Wide Range Output Voltage Operation

  • Nguyen, Minh-Khai;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.736-747
    • /
    • 2009
  • A new type of single-phase Z-source AC/AC converter based on a single-phase matrix converter is proposed in this paper. The proposed single-phase Z-source AC/AC converter has unique features; namely that the output voltage can be bucked and in-phase/out-of-phase with the input voltage; that the output voltage can be boosted and in-phase/out-of-phase with the input voltage. The converter employs a safe-commutation strategy to conduct along a continuous current path, which results in the elimination of voltage spikes on switches without the need for a snubber circuit. The operating principles of the proposed single-phase Z-source AC/AC converter are described, and a circuit analysis is provided. To verify the performance of the proposed converter, a laboratory prototype based on a TMS320F2812 DSP was constructed. The simulation and the experimental results verified that the output voltage can be bucked-boosted and in-phase with the input voltage, and that the output voltage can be bucked-boosted and out-of-phase with the input voltage.

12 Cr 강의 열피로 수명단축에 관한 연구 (A study on the thermal-mechanical fatigue life prediction of 12 Cr steel)

  • 하정수;김건영;안희돈
    • 한국정밀공학회지
    • /
    • 제11권4호
    • /
    • pp.114-125
    • /
    • 1994
  • Fatigue behavior and life prediction method were presented for themal-mechanical and isothermal low cycle fatigue of 12 Cr forged steel used for high temperature applications. In-phase and out-of-phase thermal-mechanical fatigue test from 350 .deg. C to 600 .deg. C and isothermal low cycle fatigue test at 600 .deg. C, 475 .deg. C, 350 .deg. C were conducted using smooth cylindrical hollow specimen under strain-control with total strain ranges from 0.006 to 0.015. The phase difference between temperature and strain in thermal-mechanical fatigue resulted in significantly shorter fatigue life for out-of-phase than for in-phase. Thermal-mechanical fatigue life predication was made by partitioning the strain ranges of the hysteresis loops and the results of isothermal low cycle fatigue tests which were performed under the combination of slow and fast strain rates. Predicted fatigue lives for out-of-phase using the strain range partitioning method showed an excellent agreement with the actual out-of-phase thermal-mechanical fatigue lives within a factor of 1.5. Conventional strain range partitioning method exhibited a poor accuracy in the prediction of in-phase range partitioning method in a conservative way. By the way life prediction of thermal-mechanical fatigue by Taira's equivalent temperature method and spanning fartor method showed good agreement within out-of-phase thermal-mechanical fatigue.

  • PDF

An Analytical Approximation for the Pull-Out Frequency of a PLL Employing a Sinusoidal Phase Detector

  • Huque, Abu-Sayeed;Stensby, John
    • ETRI Journal
    • /
    • 제35권2호
    • /
    • pp.218-225
    • /
    • 2013
  • The pull-out frequency of a second-order phase lock loop (PLL) is an important parameter that quantifies the loop's ability to stay frequency locked under abrupt changes in the reference input frequency. In most cases, this must be determined numerically or approximated using asymptotic techniques, both of which require special knowledge, skills, and tools. An approximating formula is derived analytically for computing the pull-out frequency for a second-order Type II PLL that employs a sinusoidal characteristic phase detector. The pull-out frequency of such PLLs can be easily approximated to satisfactory accuracy with this formula using a modern scientific calculator.

황체기능 평가에 관한 연구 (A Study on the Methods to Evaluate Adequacy of Luteal Function)

  • 배광범;김정구;문신용;이진용;장윤석
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제13권2호
    • /
    • pp.113-119
    • /
    • 1986
  • The present study was designed to assess the relationships between the methods to evaluate adequacy of luteal function. We measured mid-luteal serum progesterone levels by radioimmune assay, luteal phase lengths and mean post-ovulatory basal body temperature rise rates by basal body temperature charts in 40 in-phase-cycle infertile patients and 38 out-of-phase-cycle patients who underwent late-luteal endometrial biopsies at the sterility clinic of Department of Obstetrics and Gynecology, Seoul National University Hospital from Jan. 1986 to Aug. 1986. The results were summarized as follows: 1. No significant differences were found in mean age, mean duration of infertility, mean mid-luteal serum progesterone levels, and mean post-ovulatory temperature rise rate between in-phase-cycle patients and out-of-phase-cycle patients, but significant difference in mean luteal phase length between 2 groups was identified. 2. 91% of total patients sho had luteal phase lengths of less than 11 days showed out-of-phase-cycles. 3. In out-of-phase-cycle group with luteal phase lengths of less than 11 days, 50% had an endometrial lag of at least 4 days, but 10.7% had an endometrial lag of 4 or more days in group with luteal phase lengths of more than 11 days. 4. There was no significant correlation between mid-luteal serum progesterone level and endometrial lag of late luteal phase endometrial biopsy.

  • PDF

Single-Phase Z-Source AC-AC Converter (SZAC) with Buck/Boost In-Phase and Out-Of-Phase Operation

  • Khai, Nguyen Minh;Jung, Young-Gook;Lim, Young-Cheol
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.376-378
    • /
    • 2008
  • A new family of single-phase Z-source ac-ac converter(SZAC) based on single-phase matrix converter (SPMC) is proposed in this paper. Compared to conventional Z-source ac-ac converter, the proposed SZAC has unique feature: providing a wide range of output ac voltage with buck/boost in-phase (maintaining phase angle) and buck/boost out-of-phase (reversing phase angle) operation. A new commutation strategy is used to eliminate voltage spikes on switches. The operating principle of the proposed SZAC is presented. Analysis and experimental results are also presented.

  • PDF

Selection of Voltage Vectors in Three-Level Five-Phase Direct Torque Control for Performance Improvement

  • Tatte, Yogesh N.;Aware, Mohan V.
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2162-2172
    • /
    • 2016
  • This paper presents a Direct Torque Control (DTC) strategy for the five-phase induction motor driven by a three-level five-phase inverter in order to improve the performance of the five-phase induction motor. In the proposed DTC technique, only 22 voltage vectors out of 243 available voltage vectors in a three-level five-phase inverter are selected and are divided in 10 sectors each with a width of $36^{\circ}$. The four different DTC combinations (DTC-I, II, III and IV) for a three-level five-phase induction motor drive are investigated for improving the performance of five-phase induction motor. All four of the DTC strategies utilize a combination of the same large and zero voltage vectors, but with different medium voltage vectors. Out of these four techniques, DTC-II gives the best performance when compared to the others. This DTC-II technique is analyzed in detail for improvements in the performance of five-phase induction motor in terms of torque ripple, x-y stator flux and Total Harmonics Distortion (THD) of the stator phase current when compared to its two-level counterparts. To verify the effectiveness of the proposed three-level five-phase DTC control strategy, a DSP based experimental system is build. Simulation and experimental results are provided in order to validate the proposed DTC technique.

Thyristor를 이용한 Phase shift에 관한 연구 (A Study on the Phase Shift With the Thyrtisors Utilized)

  • 박민호;김민수
    • 전기의세계
    • /
    • 제27권6호
    • /
    • pp.63-68
    • /
    • 1978
  • To convert into multiphase from single phase are often necessary for industry field. In oder to convert of phase, phase shifted voltages are first buileded by single phase and then must combine with these voltages adequately. This paper aims at the description of the way of phase shift by means of turning on or turning off through natural commutation and forced commutation methods with firing angle of thyristor pating a role of switching controlled adequately. Experimental result of the Phase Shift with the Thyristors Utilized has been turned out to shift the phase to 60.deg., 90.deg., 120.deg., and other angles.

  • PDF

유체로 연성되고 두께가 상이한 두 직사각 평판의 실험적 모드 해석 (Experimental Modal Analysis of Two Unequal Rectangular Plates Coupled with Fluid)

  • 유계형;정경훈;이성철
    • 대한기계학회논문집A
    • /
    • 제26권12호
    • /
    • pp.2541-2549
    • /
    • 2002
  • In order to study the vibration characteristics of fluid-structure interaction problem, two rectangular plates coupled with bounded fluid were investigated. Experimental modal analyses were carried out to extract the modal parameters of the system. Additionally. finite element modal analyses performed using a commercial computer code, ANSYS. The FEM solutions were compared with the experimental solutions to verify the finite element model. As a result, the comparison between the experiment and FEM results showed excellent agreement. The transverse vibration modes, in-phase and out-of-phase, were observed alternately in the fluid-coupled system. The thickness effect of the plates on the fluid-coupled natural frequencies and mode shapes was investigated for two different cases with the identical thickness and the unequal thickness. It was found that the coupled natural frequencies increase with the thickness for the identical plates regardless of the mode phase. The experimental and the finite element analysis results showed that the out-of-phase mode shapes were deviated from the symmetrical mode shapes in the plate transverse direction fur the unequal plate thickness case.