• Title/Summary/Keyword: In-house Design Department

Search Result 282, Processing Time 0.049 seconds

Heating and Cooling Energy Demand Analysis of Standard Rural House Models (농어촌 주택 표준모델의 냉난방에너지요구량 분석)

  • Lee, Chan-Kyu;Kim, Woo-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3307-3314
    • /
    • 2012
  • The annual energy demand of the standard rural house models was analyzed using the DesignBuilder. Indoor temperature set-point, U-value of outer wall, type of window, and degree of ventilation were selected as simulation parameters. In all the simulation cases, heating energy demand was higher than cooling energy demand regardless of the building size. When the lower U-value of the outer wall was applied to account for the thicker insulation layer, heating energy demand was decreased while cooling energy demand was increased. However, it is better to reduce the area of outer wall which is directly exposed to outdoor air because reducing the U-value of the outer wall is not effective in decreasing heating energy demand. Among the four different window types, the double skin window is most favorable because heating energy demand is the lowest. For a fixed infiltration rate, higher ventilation rate resulted in an increased heating energy demand and had minor impact on cooling energy demand. As long as the indoor air quality is acceptable, lower ventilation rate is favorable to reduce the annual energy demand.

Analysis of Techniques for Carbon Reduction in Residential Construction (주거건축에서의 탄소저감을 위한 기법 분석)

  • Kim, Minsoo;Lee, Taegoo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.26 no.2
    • /
    • pp.9-16
    • /
    • 2024
  • In order to achieve carbon neutrality in the architectural field by 2050, this study analyzed the energy impact proportional to CO2 emissions of each technique, such as design methods, the properties of building structures, prefabrication methods, passive houses, and active facilities. In addition, the results were presented quantitatively in terms of carbon reduction, and corresponding housing cases were analyzed. The research method is limited to residential buildings at the Passive House energy level, and carbon reduction techniques and elements in architecture are examined through various literature and materials, and empirical cases are analyzed to determine the specific possibility of realizing carbon reduction in architecture. We want to secure it. Based on these analysis results, it was possible to suggest that it is possible to explore various approaches to carbon reduction in future residential construction. By combining the most efficient techniques according to the energy reduction level or goal setting of the building in question, we expect the possibility of achieving the goal of carbon reduction in the residential sector more realistically.

The Analysis of the Design Characteristics of Wooden Houses in order to Develop Korean Modern Wooden Houses (한국형 중목구조 주택 표준화 개발을 위한 목조주택의 디자인 특성 분석)

  • Lee, Jusuk
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.537-549
    • /
    • 2017
  • Wooden houses are classified into Traditional, Modern, Platform, Timber framing types. The most popular type is Platform framing which is come from foreign culture. The foreign and Korean tree structure tend to be incompatible with Korean culture and don't fit well with modern lifestyle. In this study, it will analyze the design characteristics of the traditional and modern wooden house to solve these problems. The design characteristics will be contributed to the development of wooden architecture which is suitable for Korean architectural style and lifestyle The research consists of space analysis, plane analysis, structural system analysis, roof type analysis, and aesthetic analysis. From the analytical results the design characteristics of traditional Hanok and modern wood structure, we propose the modular elements and the inner and outer shapes of the Korean - style wooden house.

Structural Design of an Upper Control Arm, Considering Static Strength (정강도를 고려한 상부 컨트롤 암의 구조설계)

  • Song, Byoung-Cheol;Park, Han-Seok;Kwon, Young-Min;Kim, Sung-Hwan;Park, Young-Chul;Lee, Kwon-Hee
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.190-196
    • /
    • 2009
  • This study proposes a structural design method for the upper control arm installed at the rear side of a SUV. The weight of control arm can be reduced by applying the design and material technologies. In this research, the former includes optimization technology, and the latter the technologies for selecting aluminum as a steel-substitute material. Strength assessment is the most important design criterion in the structural design of a control arm. At the proto design stage of a new control arm, FE (finite element) analysis is often utilized to predict its strength. This study considers the static strength in the optimization process. The inertia relief method for FE analysis is utilized to simulate the static loading conditions. According to the classification of structural optimization, the structural design of a control arm is included in the category of shape optimization. In this study, the kriging interpolation method is adopted to obtain the minimum weight satisfying the strength constraint. Optimum designs are obtained by ANSYS WORKBENCH and the in-house program, EXCEL-kriging program. The optimum results determined from the in-house program are compared with those of ANSYS WORKBENCH.

A study on CFRP based lightweight House deck structure design and configuration of Deck body connected IoT sensor data acquisition devices

  • Jaesang Cha;Chang-Jun Ahn;Quoc Cuong Nguyen;Yunsik Lim;Hyejeong Cho;Seung Youn Yang;Juphil Cho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.250-260
    • /
    • 2023
  • In this paper, we designed a IoT(Internet of Things) sensor block embedded lightweight house deck structures that can be implemented using Carbon Fiber Reinforced Polymer(CFRP). Deck-Sensor interconnection interface block via IoT connectivity Hub that can mount external environmental sensors such as fire sensors on the Deck body itself was also proposed. Additionally we described the configuration of devices for data acquisition and analysis based on IoT environmental detection sensors that can be commonly installed and used on these deck bodies. On the other hand, received sensing data based monitoring user interface(UI) also developed and used for sensing data analysis for remote monitoring center. Through the implementation of such IoT-based sensor data transmission and collection analysis devices and UI software, this paper confirmed the availability of CFRP based lightweight House deck structure and possibility of CFRP deck-based IoT sensor data networking and analysis functions.

A Study on the Method of Using Plants and Preference Analysis for Interior Space (실내공간에 있어서 식물 이용 방법과 선호도 분석에 관한 연구)

  • 김태환;한승원
    • Korean Institute of Interior Design Journal
    • /
    • no.11
    • /
    • pp.31-37
    • /
    • 1997
  • This study intens to provide available guideline of useful plants in interior and be used by designer. It focuses on evaluating the character of plants, the method of installation and the form of composition for suitable design of using plants. The study finds out that using plants in interior are necessary positively by 94% respondents. And results of factor analysis are that plants are needed for emothional stability(factor 1), visual charming(factor 2), and educational effection(factor 3). According to job, the group of students is visual charming (P=0.0037), the public servants and housewives is educational effection(p=0.0029). The most available space of plants as follows : Department(30.5%), Hotell(26.3%), House and Restuarant(12.7%). It has been identified that the public institution and commercial space are much indused plants. The most indused plants in house is ordered that the veranda, the living room, the entrance. This result is concerned about relation of natural light plants. The repondants reply that the favorite arrangement style is the corner form(63%), the center garden form(52.1%), the large planter(19.7%), the planter box(11.3%). They respond that they are more favorite light green color than dark, and mono color than mixture color. Finally, interior Designers should be understood the functional and aesthetic elements and the special interest about plants for developing desigv.

  • PDF

Calculation of the Theoretical Total Amount Ratio of Di(2-ethyl-hexyl) Phthalate in Indoor Air and Floor Dust in a Test House (모의 실험주택 모니터링 결과를 활용한 실내공기 및 바닥먼지 중 Di(2-ethyl-hexyl) phthalate (DEHP)의 이론적 총량 비율 산출)

  • SaHo Chun;Khawon Lee;SeungJung Kim;SeungPyo Jung;DaYoung Kang;Ki-Tae Kim
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.6
    • /
    • pp.324-333
    • /
    • 2023
  • Background: Human exposure to phthalates in indoor environments occurs via dermal absorption, oral ingestion of indoor dust, and inhalation of indoor air. However, systematic studies to investigate the exposure rate to phthalates among the three exposure routes in indoor environments are currently limited. Objectives: A theoretical exposure ratio between inhalation and oral exposure was calculated based on the total amount of di(2-ethyl-hexyl) phthalate (DEHP) emitted into indoor air and deposited into floor dust in a test house. Methods: Flooring and wallpaper containing DEHP were installed in a test house and the concentration of DEHP in both indoor air and floor dust were monitored for five months. Based on the measured DEHP concentrations, the theoretical total amount ratio of DEHP that could be exposed through inhalation and oral ingestion was calculated. Results: Considering the period of operation in the test house, the theoretical total amount of DEHP through inhalation and oral ingestion exposures in the entire test house space was calculated to be 0.014 mg and 5.5 mg, respectively. The exposure ratio of the two routes between inhalation and oral exposure corresponding to the total DEHP amount in flooring and wallpaper was 6.0×10-7% and 2.3×10-4%, indicating that theoretical oral exposure to DEHP is approximately 380 times higher than inhalation. Conclusions: Monitoring results from a test house has shown that oral exposure is the main exposure route for DEHP in indoor environments. The experimental design employed in this study and theoretical exposure ratio obtained can be applied to investigate actual exposure to DEHP and to determine the exposure characteristics of various types of semi-volatile organic compounds.

Analysis of the Initial Cost Payback Period on the Open-loop Geothermal System Using Two Wells (복수정을 이용한 개방형 지열 시스템의 초기투자비 회수기간 분석)

  • Cho, Jeong-Heum;Nam, Yujin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.119-126
    • /
    • 2017
  • Recently, ground source heat pump systems are being used in buildings for cooling and heating to reduce greenhouse gas and save energy. However, ground source heat pump systems mainly use the vertical closed-loop geothermal system design rather than the open-loop geothermal system design. This is due to a lack of knowledge and few research feasibility studies. In this research, a dynamic thermal analysis numerical simulation based on a standard house model was conducted for an open-loop geothermal system. Based on heating load analysis results, the life cycle costs of a standard house using an open two-well geothermal system were analyzed and compared with a vertical closed-loop geothermal system, and a diesel boiler. As a result, it was found that using an open two-well geothermal system shows economic return on investment after three years.

A Study on the Change of Exclusive Space for Balcony Expansion in an Apartment - Focused on an Apartment House below 85m2 of Exclusive Area- (아파트 발코니 확장에 따른 전용공간의 변화에 관한 연구 - 전용면적 85m2형 공동주택을 대상으로 -)

  • Bae, Dong-Sig
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.2
    • /
    • pp.11-18
    • /
    • 2018
  • The purpose of this study is to analyze the structure and use change of the private space according to the balcony expansion and use it as the data of plan design. According to Bay, front length/width ratio and the change of balcony space before and after expansion of space organization of house units were analyzed. Common characteristics of Flat type and Tower type are an increase of the frontage length of house units in an apartment, an increase of the number of front bay, and an increase of integrated LDK focusing on living room. A difference is that Flat type shows high frontage ratio, Bay figure, and spatial arrangement favorable to front openness and lighting. Flat type shows higher area distribution than Tower type in LDK area distribution located in at the plane center. Spatial expandability and visual openness of Flat type are more beneficial than those of Tower type in the planning, and a balcony extension of house units has developed to direction to open more. Tower type creates various block images through a combination of house units focusing on the core. Uses after balcony expansion are area expansion of a balcony-neighboring room, storage space, expansion and function improvement of the variable range, and specialized space different from a neighboring room. In addition, there is no escapable space except for a shelter, so unit plan should be prepared to prevent using it other space of a shelter and to solve moving line of two-way horizontal refuge and vertical refuge.

The Analysis of a Structural Stability of a 50ton Container Crane according to an Increased Design Wind velocity (설계풍속 상향 조정에 따른 50ton급 컨테이너 크레인의 구조 안정성 평가)

  • Kwon Soon-Kyu;Lee Seong-Wook;Han Dong-Seop;Shim Jae-Joon;Han Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.241-246
    • /
    • 2005
  • This study is carried out to analyze the stability of a container crane in according to the change of a wind direction and a machinery house location when a wind load of a wind velocity, 75m/s was applied on the state stowing a container crane by a heavy wind A design wind load applied to this study was calculated in observance of 'Load Criteria of Building Structure'. And we analyzed the reactions of each supporting points according to appling a wind direction to an interval of $15^{\circ}$ in $0^{\circ}\~180^{\circ}$ and the structure stability of a container crane according to changing a machinery house location occupying $15\%$ of a container crane weight. From a results of this study, we presented a design criteria of an overturning disturbance equipment, tie-down.

  • PDF