• 제목/요약/키워드: In-Flight Calibration

검색결과 70건 처리시간 0.025초

비행시험을 통한 경비행기의 속도계 보정에 대한 연구 (Airspeed and Altitude Calibration of Light Airplane via Flight Test)

  • 이정훈;김성훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.891-896
    • /
    • 2007
  • This paper contained the flight test calibration for the airspeed indicator and the altimeter of the light airplane ChangGong-91, which is the first type certified aircraft from Korean Ministry of Construction and Transportation, as a part of the flight test validation. The flight test for airspeed position error calibration was performed using tower fly by method in order to calibrate swivel head testboom which is attached to the right wing tip of the airplane, and using system to system method for airspeed indicator. The altimeter calibration was calculated using flight test data for airspeed calibration. The flight test was conducted at the basis of the 'Korean Airworthiness Standard' regulation of Korean Ministry of Construction and Transportation.

  • PDF

비행시험을 통한 경비행기의 속도계 보정 (Airspeed Calibration of a Light Airplane via Flight Test)

  • 이정훈;류시융;이장호
    • 제어로봇시스템학회논문지
    • /
    • 제14권7호
    • /
    • pp.629-634
    • /
    • 2008
  • This paper presents the flight test procedure and the results for the airspeed indicator calibration of a light airplane the name of ChangGong-91, which is the first type certified aircraft from Korean Ministry of Construction and Transportation, as a part of the flight test validation to get the certification. The flight tests for airspeed position error calibrations are conducted using tower fly by method in order to calibrate swivel head testboom which is attached to the right wing tip of the airplane. Also system to system method is applied in order to calibrate the airspeed indicator of the cockpit. The flight test is conducted at the basis of the 'Korean Airworthiness Standard' which is the regulation of Korean Ministry of Construction and Transportation. The airspeed error range for the testboom and the airspeed indicator are determined to $-0.75{\sim}+0.75$ knot and to $-4.0{\sim}+2.0$ knots, respectively. The calibration results are applied to ChangGong-91 Flight Operation Manual.

항공 시스템 기반의 통신신호 방향 탐지를 위한 비행 보정 기법 (In-Flight Calibration Method for Direction Finding of Communication Signals based on Aviation Systems)

  • 장재원;주증민
    • 한국전자파학회논문지
    • /
    • 제30권4호
    • /
    • pp.290-299
    • /
    • 2019
  • 신호를 송출하는 신호원의 방향을 추정하기 위하여 다수개의 안테나를 이용하는 방향 탐지 장치는 조난자를 구출하거나 규정된 송신원의 위치를 파악하기 위하여 사용된다. 방향 탐지를 수행할 때에는 방향 탐지 장치와 다수개의 안테나를 탑재한 시스템의 외형과 재질에 따라서 반사파가 존재하고 신호의 왜곡이 발생된다. 따라서 신호원의 방위각을 정확하게 추정하기 위해서는 방향 탐지 장치 개발 간에 안테나 배치와 시스템 외형에 따른 영향성을 반영하기 위한 보정을 수행해야만 한다. 본 논문에서는 항공 시스템을 이용한 통신신호 방향 탐지 장치 개발을 위하여 수행되는 비행 보정기법을 설명하고, 비행 보정을 통하여 얻게 된 위상 보정 데이터를 적용할 경우의 방향 탐지 성능을 분석한다.

Improved Calibration for the Analysis of Emerging Contaminants in Wastewater Using Ultra High Performance Liquid Chromatography and Time-of-Flight Mass Spectrometry

  • Pellinen, Jukka;Lepisto, Riikka-Juulia;Savolainen, Santeri
    • Mass Spectrometry Letters
    • /
    • 제9권3호
    • /
    • pp.77-80
    • /
    • 2018
  • The focus of this paper is to present techniques to overcome certain difficulties in quantitative analysis with a time-of-flight mass spectrometer (TOF-MS). The method is based on conventional solid-phase extraction, followed by reversed-phase ultra high performance liquid chromatography of the extract, and mass spectrometric analysis. The target compounds included atenolol, atrazine, caffeine, carbamazepine, diclofenac, estrone, ibuprofen, naproxen, simazine, sucralose, sulfamethoxazole, and triclosan. The matrix effects caused by high concentrations of organic compounds in wastewater are especially significant in electrospray ionization mass spectroscopy. Internal-standard calibration with isotopically labeled standards corrects the results for many matrix effects, but some peculiarities were observed. The problems encountered in quantitation of carbamazepine and triclosan, due to nonlinear calibration were solved by changing the internal standard and using a narrower mass window. With simazine, the use of a quadratic calibration curve was the best solution.

경량항공기 선형 비행운동모델 변수 추정에 관한 연구 (Study on the Parameter Estimation for Flight Dynamic Linear Model of Light Sport Aircraft)

  • 김응태;성기정
    • 한국항공운항학회지
    • /
    • 제18권4호
    • /
    • pp.21-29
    • /
    • 2010
  • The main purpose of this study is to obtain linear models for the design of automatic flight controller in order to operate the Light Sport Aircraft as unmanned air vehicle. Flight test equipments installed on the aircraft to acquire flight test data are described and maneuvers for practical speed calibration are introduced. Parameters for the linear models of lateral and longitudinal motion are estimated by the Output error method as well as trim data analysis using the flight test data. Simulated data using the estimated parameters is shown to agree well with the measurement data. Estimated parameters obtained for several flight conditions can be used to improve the aerodynamic database of the simulation program.

Combined Static and Dynamic Platform Calibration for an Aerial Multi-Camera System

  • Cui, Hong-Xia;Liu, Jia-Qi;Su, Guo-Zhong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권6호
    • /
    • pp.2689-2708
    • /
    • 2016
  • Multi-camera systems which integrate two or more low-cost digital cameras are adopted to reach higher ground coverage and improve the base-height ratio in low altitude remote sensing. To guarantee accurate multi-camera integration, the geometric relationship among cameras must be determined through platform calibration techniques. This paper proposed a combined two-step platform calibration method. In the first step, the static platform calibration was conducted based on the stable relative orientation constraint and convergent conditions among cameras in static environments. In the second step, a dynamic platform self-calibration approach was proposed based on not only tie points but also straight lines in order to correct the small change of the relative relationship among cameras during dynamic flight. Experiments based on the proposed two-step platform calibration method were carried out with terrestrial and aerial images from a multi-camera system combined with four consumer-grade digital cameras onboard an unmanned aerial vehicle. The experimental results have shown that the proposed platform calibration approach is able to compensate the varied relative relationship during flight, acquiring the mosaicing accuracy of virtual images smaller than 0.5pixel. The proposed approach can be extended for calibrating other low-cost multi-camera system without rigorously mechanical structure.

무인항공기 비행제어컴퓨터 알고리즘 개발을 통한 비행안전성 향상 (A UAV Flight Control Algorithm for Improving Flight Safety)

  • 박순철;정성록;정명진
    • 정보과학회 논문지
    • /
    • 제44권6호
    • /
    • pp.559-565
    • /
    • 2017
  • 무인항공기는 사람이 탑승하지 않고 미리 설계된 프로그램에 따라 동작하기 때문에 전자기 간섭 등의 외부 영향에 대해 높은 신뢰성을 요구한다. 하지만 소형 무인항공기는 무게 및 공간의 제약으로 인해 외부 영향에 대해 물리적으로 완벽한 저항성을 가지도록 만들기가 어렵다. 이러한 여건으로 인해 기존에 운용 중인 소형 무인항공기는 외부 영향으로 비행제어 컴퓨터가 재시작 될 경우 비행체가 추락하는 상황이 발생하기도 하였다. 따라서 본 논문에서는 소형 무인항공기 비행안전성 향상을 위한 비행제어컴퓨터 알고리즘을 제안한다. 제안하는 알고리즘은 3개의 단계로 이루어져 있다. 첫 번째 단계는 항법장비를 교정하고 유효성을 검증하는 것이다. 두 번째 단계는 이륙단계에 교정데이터를 저장하는 것이다. 세 번째 단계는 비행제어컴퓨터 재시작 발생 시 현재 비행 상태를 판단하고, 비행 중일 경우에 교정데이터를 복구하는 것이다. 제안하는 알고리즘을 실제 소형 무인기에 적용하여 시험한 결과 비행제어컴퓨터가 재시작 되는 상황에도 안전하게 비행 유지가 가능함을 확인할 수 있었다.

초음파 및 무선 통신 파를 이용한 자기 위치와 비컨 위치 인식 시스템 (Robot localization and calibration using Ultrasonic and Ratio Frequency)

  • 윤정용;정규식;신동헌
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1040-1044
    • /
    • 2005
  • This paper presents a method for the robot localization and calibration using the ultrasonic and the radio frequency. The distance between the receiver and a beacon can be computed by using the difference between times of flight. The presented method uses the gradient of the maximum amplitude of the ultrasonic in order to measure the time of flight precisely. The measured three distances between the receiver and the beacon are used to compute the robot position by the direct inverse method and the iterated least square approximation method. This paper is defined the calibration as the problem to find the location of 3 beacons and 3 robots, and presents 3 methods for it and found the 2B2R method as the best among them.

  • PDF

BITSE Preliminary Result and Future Plan

  • Bong, Su-Chan;Yang, Heesu;Lee, Jae-Ok;Kwon, Ryun Young;Cho, Kyung-Suk;Kim, Yeon-Han;Reginald, Nelson L.;Yashiro, Seiji;Gong, Qian;Gopalswamy, Natchumuthuk;Newmark, Jeffrey S.
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.58.2-58.2
    • /
    • 2019
  • BITSE is a technology demonstration mission to remotely measure the speed, temperature, and density of the solar wind as it forms as close as 3 Rs. BITSE obtained coronal images during its one day flight above more than 99% of the atmosphere, and calibration data are taken in the laboratory as well as during the flight. As the linearly polarized K-corona is much fainter than other bright sources like diffraction, sky, and F-corona, a careful data reduction is required to obtain reliable scientific results. We will report status of the obtained data, the reduction progress, and future plan.

  • PDF