• Title/Summary/Keyword: Impulse current surge

Search Result 68, Processing Time 0.032 seconds

Transient Impedance of the Ground Grid and Deeply-driven Ground Rod (그리드접지와 심매설 접지전극의 과도임피던스)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Jung, Hyun-Uk;Jeong, Dong-Cheol;Gil, Hyoung-Jun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.240-243
    • /
    • 2005
  • This paper presents the transient behaviors of grounding system impedance against lighting impulse currents. The dynamic characteristics of the deeply driven ground rod and grounding grid subjected to the impulse current with various rise time were investigated. It was found that the transient ground impedance strongly depends on the configuration and size of grounding electrodes and the shapes of impulse currents, and the inductance of grounding electrodes has a significant affect on the transient ground impedance of grounding system in the short time domain.

  • PDF

Transient impedance characteristics according to the injection position of deep-driven ground rods (심매설 접지전극의 전류인가위치에 따른 과도접지임피던스 특성)

  • Lee, Bok-Hee;Li, Feng;Lee, Su-Bong;Lee, Song-Zhu;Jeon, Byung-Wook;Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.297-300
    • /
    • 2008
  • This paper presents the behaviors of transient and conventional grounding impedances of a deep-driven ground rods associated with the injection point of lightning impulse currents. The transient impedance of deep-driven ground rods under lightning impulse currents were higher than the static ground resistance. The transient grounding impedances strongly depend on the injection point and size of grounding electrodes and the rising time of impulse current. Reduction of ground system inductance is an important factor to lightning surge protection.

  • PDF

Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices (서지 보호기의 열화 특성과 온라인 진단장치)

  • Park, Kyoung-Soo;Wang, Guoming;Hwang, Seong-Cheol;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

Evaluation of 띠ectrical Uniformity of Zinc Oxide Varistors for Lightning Surge Arresters (초고압 피뢰기용 산화아연소자의 전기적 균일성 평가)

  • Cho, Han-Goo;Yoon, Han-Soo;Han, Se-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.100-102
    • /
    • 2005
  • This paper presents evaluation of the electrical uniformity of zinc oxide varistors for lightning arresters. Two types of varistors were prepared which are a domestic varistor destroyed in the long duration current impulse withstand test and a new imported varistor. The domestic varistor exhibited good electrical uniformity except destroyed parts, but the imported varistor showed the worse results.

  • PDF

Transient Ground Impedances According to Shapes of Grounding Electrodes (접지전극의 형상에 따른 과도접지임피던스)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Jung, Hyun-Uk;Jeong, Dong-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.65-70
    • /
    • 2006
  • This paper presents the transient behaviors of grounding system impedance against lightning impulse currents. The dynamic characteristics of the deeply driven ground rod and grounding grid subjected to the impulse current were investigated. The transient ground impedance strongly depends on the configuration and size of grounding electrodes and the shapes of impulse currents, and the inductance of grounding electrodes has a significant affect on the transient ground impedance of grounding system Also, the deeply-driven ground rod was effective to reduce the transient ground impedance in time domain of miceroseconds.

A Comparison on the Resistance and characteristics of Transient response of Grounding Systems under Surge Currents (서지 전류에 의한 접지계의 과도응답 특성 및 접지저항 비교)

  • Shin, D.H.;Kim, Y.;Jung, Chul-Hee;Cho, Dae-Hoon;Kim, Pil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.222-225
    • /
    • 1999
  • This paper presents the surges response of the grounding systems using frequency domain electromagnetic field analysis software package. The frequency and time domain performance of a building grounding systems subjected to a lighting strike is described and discussed. The computed scalar potentials is presented graphically as a function of spatial coordinates. A double exponential lighting surge current is injected at one corner or the building grounding systems. Time-variant response of rod, mesh and kit grounding systems under impulse currents have been obtained. This paper deals with the results of studies on the time variation of ground resistance in three grounding systems.

  • PDF

Characteristics of Transient Grounding Impedances of Rod Electrodes (봉상접지극의 임펼스 전류에 대한 과도접지임피던스 특성)

  • Lee, B.H.;Park, J.S.;Yang, J.J.;Lee, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1645-1647
    • /
    • 1997
  • Electronic circuits are becoming more vulnerable owing to the development of integrated circuit. Computer and info-communication facilities are very sensitive to surges caused by lightning, and they can suffer a malfunction and damage. Recent concern about damage and upset caused by transient overvoltages has focused on surge protection. The most important parameter in surge protection is the transient grounding impedance. In this paper, the transient grounding impedances of a rod electrode have been measured under impulse current waves. Z-t, Z-i and V-i characteristics of the grounding electrode in according to the length of the grounding lead wire were obtained and analyzed.

  • PDF

A Rise in Electric Potential of Telecommunication Line for Electric Power System by Lightning Surges (뇌서지에 의한 전력통신선로의 전위상승)

  • Lee, Bok-Hee;Chang, Sug-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1718-1720
    • /
    • 1997
  • This paper deals with n rise in electric potential of telecommunication line for electric power system by lightning surges. When $1.2/50{\mu}s$ and $8/20{\mu}s$ impulse voltage and current were applied on telecommunication cable, the voltage waveforms at the end terminal and equipment were measured. The telecommunication lines, which consist of 60 conductors and 3.5km in length, have some surge protectors such as preposition lightning arrester and TVSS. In each case, the rise in electric potential was measured for differential mode and common mode, respectively. Also, the rise in ground potential and the induced voltages were measured and analyzed. As a result, a significant rise in ground potential was observed for lightning surge. It can cause failure or malfunction of telecommunication systems.

  • PDF

A Study on the Development of a Transient Voltage Stocking Device for Signal and Telecommunication Lines (신호.통신회로용 과도전압 차단장치 개발에 관한 연구)

  • 송재용;이종혁;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.490-493
    • /
    • 1999
  • Due to the miniaturization of electrical components and assembles on signal and telecommunication circuits, transient overvoltages caused by switching operation or lightning surge has become more interesting concern to the field of electrical engineering. This paper describes the development of transient voltage blocking devices (TBDs) that can protect sensitive signal and telecommunication devices from overvoltages. Two kinds of TBDs are designed and tested by using a combination surge generator which can produce the standard impulse current of 8/20${\mu}$s 2.1kA according to the IEC 1000-4-5 standard. From the simulation and experimental reults, it is confirmed that the proposed TBD has an enough protection performance in low insertion loss and tight clamping voltage.

  • PDF

Performance Evaluation of Class I SPD Using $10/350{\mu}s$ Surge Current ($10/350{\mu}s$ 서지전류를 이용한 I 등급 SPD의 성능평가)

  • Cho, Sung-Chul;Eom, Ju-Hong;Lee, Tae-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1466-1467
    • /
    • 2007
  • A new parameter W/R for the class I test have been introduced in the IEC 61643-1 published in 2005. One of the possible test impulses which meets the parameters for class I test is the 10/350 [${\mu}s$] waveshape proposed in IEC61312-1. 10/350 [${\mu}s$] waveshape meets parameters for class I test in the IEC 61643-1. The impulse generator for making the 10/350 [${\mu}s$] waveshape is consist of IVG, ICG, crowbar coil and crowbar switch. The electric change Q and the specific energy W/R were measured and calculated using the exclusive use measuring software according to the formula of IEC 611643-1. We verified the correspondence between measured results using impulse generator and recommended parameters by IEC 61643-1.