• 제목/요약/키워드: Impulse current generator

검색결과 50건 처리시간 0.022초

이동식 ICG를 이용한 과도접지임피던스 측정 시스템 구축 (Installation of Measuring System for the Transient Ground Impedances using Portable Impulse Current Generator)

  • 이태형;조성철;엄주홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.199-201
    • /
    • 2007
  • This paper presents the installation of measuring system for the transient behaviors of grounding system impedances using portable impulse current generator. The measuring system is controller, with controller, power supply, impulse current generator and data aquisition system. In the evaluation of the impulse response in a ground electrode, the step response is calculated based on the ratio of the voltage and current observed.

  • PDF

임펄스 발생기의 회로 설계 파라미터 예측계산과 10/350${\mu}s$ 뇌임펄스 전류발생기 적용 (Design Circuit Parameter Estimation of Impulse Generator and its application to 10/350${\mu}s$ Lightning Impulse Current Generator)

  • 이재복;;장석훈;명성호;조연규
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1822-1828
    • /
    • 2008
  • This paper presents design parameter calculation methodology and its realization to construction for the 10/350${\mu}s$ lightning impulse current generator(ICG) modelled as double exponential function waveform with characteristic parameters ${\alpha},{\beta}$. Matlab internal function, "fzero" was applied to find ${\lambda}={\alpha}/{\beta}$ which is solution of nonlinear equation linearly related with two wave parameter $T_1$ and $T_2$. The calculation results for 10/350${\mu}s$ lightning impulse current show very good accuracy with error less 0.03%. Two type of 10/350${\mu}s$ ICGs based on the calculated design circuit parameters were fabricated by considering the load variation. One is applicable to the MOV based Surge protective device(SPD) for less 15 kA and the other is to test small resistive devices such as spark gap arrester and bonding device with maximum current capability 30 kA. The tested waveforms show error within 10% in comparison with the designed estimation and the waveform tolerance recommended in the IEC 61643-1 and IEC 60060-1.

비선형 부하를 고려한 감쇠 진동형 임펄스 전류발생기의 설계 기법 (Optimum Design Methodology of the Damped Oscillatory Impulse Current Generator Considering a Nonlinear Load)

  • 장석훈;이재복;;명성호;조연규
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2255-2262
    • /
    • 2008
  • This paper presents a design parameter calculation methodology and its realization to construction for the damped oscillatory impulse current generator(ICG) modelled as damping factor $\alpha$. Matlab internal functions, "fzero" and "polyfit" are applied to find a which are solutions of second order nonlinear equation related with three wave parameters $T_{1},T_{2}$ and $I_{os}$. The calculation results for standard impulse current waveforms such as 4/10${\mu}s$, 8/20${\mu}s$ and 30/80${\mu}s$ show very good accuracy and this results make it possible to extend to generalization in the design of damped oscillatory lCG with any capacitor. 8/20${\mu}s$ ICG based on the calculated design circuit parameters is fabricated in consideration of the nonlinear load(MOV) variation. Comparisons of the tested waveforms with the designed estimation show error within 10% for the waveform tolerance recommended in IEC 60060-1 and IEEE std. C62.45.

산화아연형 피뢰기 소자의 뇌충격전류에 의한 특성 변화 (Change of the Characteristics of ZnO Arrester Blocks by Lightning Impulse Current)

  • 한주섭;송재용;길경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.907-909
    • /
    • 1998
  • This paper describes the effect of impulse current on degradation of ZnO blocks. In this study, an impulse current generator which can produce 8/20 [${\mu}s$], 3 [kA] and 4/10 [${\mu}s$], 5 [kA] waveform is designed and fabricated to simulate the lightning impulse current. The residual voltage, reference voltage, and leakage current flowing to the ZnO blocks are observed. The experimental results show that the leakage current increases continuously with the number of applied impulse current, but no significant changes in residual voltage and in operating voltage are observed until the ZnO block is destroyed. Also, it is confirmed that the main factor on degradation of ZnO blocks is rather the total energy applied to ZnO blocks than the peak value of the impulse current.

  • PDF

Crowbar 장치를 이용한 최초 단시간뇌격전류 발생기술 및 뇌격전류발생기 개발 (Development of Lightning Current Generator and Technology for Generating the First Short Stroke Lightning Current Using a Crowbar Device)

  • 엄주홍;이태형;권기량;조성철
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.93-100
    • /
    • 2011
  • This paper presents a technical study for the first short stroke lightning current generator using a crowbar device. The so-called crowbar-technology is most common to make 10/350[${\mu}s$] impulse currents with high amplitude, and the lightning current generator with crowbar device has an economic advantage than the nominal RLC current generator. But both the operating efficiency and the operating reliability of crowbar spark gap are very important to design the current generator. So, the peaking circuit which consists of small capacitors and a spark gap is applied. And the multi-step coil for controlling the circuit constant at the different test conditions is used. The presented test facility is designed to perform impulse tests with amplitudes up to 50[kA] of 10/350[${\mu}s$].

뇌충격전류에 의한 산화아연형 피뢰기 소자의 전기적 특성변화 (Change of Electrical Characteristics of ZnO Arrester Blocks by Lightning Impulse Current)

  • 길경석;한주섭;박영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권7호
    • /
    • pp.550-555
    • /
    • 1999
  • This paper deals with the effect of lightning impulse current on electrical characteristics of ZnO blocks used in distribution lightning arrester. The electrical characteristics of ZnO blocks are degraded by overtime impulse current, and the degraded ZnO block is brought to a thermal runaway and finally destroyed. It is therefore important to estimate the change of electrical characteristics of ZnO blocks. In this study, an impulse current generator which can produce 8/20$[\mus]$, 3[㎄] and 4/10$[\mus]$, 5[㎄] waveform is designed and fabricated to simulate the lightning impulse current of power systems. Total energy applied to the ZnO blocks at each time is 739[J] in 8/20$[\mus]$, and 523[J] in 4/10$[\mus]$, impulse current, respectively. From the experimental results, the 3rd harmonic of the leakage current increases continuously with the number of applied impulse current, but no significant changes in residual voltage and in reference voltage are observed until the ZnO block is destroyed. Also, it is confirmed that the main factor on degradation of ZnO blocks is rather the total energy applied to ZnO blocks than the peak value of the impulse current.

  • PDF

반도체 레이저의 이득스위칭을 이용한 UWB 임펄스 발생기 설계 (Design of Impulse generator Using Gain-Switched Semiconductor Laser for UWB)

  • 권순영;김범주;박종대
    • 대한전자공학회논문지TC
    • /
    • 제42권6호
    • /
    • pp.61-66
    • /
    • 2005
  • 본 논문에서는 Step recovery diode와 반도체 레이저의 이득 스위칭을 이용하여 UWB(Ultra Wide Band) 통신 시스템의 구성요소 중 하나인 임펄스 발생기를 설계하였다. 구현된 임펄스 발생기는 4부분으로 구성하였으며, 1번째는 SRD를 이용하여 반도체 레이저의 이득스위칭을 위한 1차 임펄스 발생기, 2번째는 출력된 1차 임펄스를 이득 스위칭을 조건에 맞추기 위한 전류조절기, 3번째는 1차 임펄스 발생기에서 출력된 임펄스를 반도체 레이저의 이득 스위칭을 이용하여 가우시안 펄스를 발생하는 2차 임펄스 발생기, 4번째는 구현된 가우시안 펄스를 UWB를 위한 가우시안 모노펄스로 변환하는 펄스 변환부로 구성되어 있다. 측정된 가우시안 모노펄스는 시간상에서 360 psec의 펄스폭과 -70 mV에서 +50 mV의 크기를 가지며, 주파수상에서 -41 dBm의 크기와 3.6 GHz의 대역폭을 가짐으로써 UWB를 위한 임펄스에 적합함을 확인하였다.

대전류 임펄스에 대한 소규모 메쉬전극의 과도접지임피던스 특성 (Characteristics of Transient Ground Impedance of a Scaled Grounding Grid on the High Current Impulse)

  • 이태형;조성철;엄주홍;유양우;이복희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1418_1419
    • /
    • 2009
  • This paper presents the transient impedance when high current impulse up to 5 kA is applied to a scaled grounding grid in test field. For a realistic analysis of transient impedance on the high current impulse in the ground systems, grounding electrode installed outdoors and impulse current generator was used. The results were discussed based on its voltage and current trace, impulse impedance and V-I curve.

  • PDF

서지전류에 의한 누전차단기의 의도하지 않은 트립에 대한 신뢰성 (Reliability on the Unintended Trips of Residual Current Operated Circuit Breakers due to Surge Currents)

  • 이복희;김상현;김유하
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.79-84
    • /
    • 2012
  • As the huge economical loss and function paralysis of information technology-based systems can be caused by the misoperation of residual current devices(RCDs) due to surge voltages and currents, RCDs shall not operate by surge currents. In this paper, in order to evaluate the reliability of residual current operated circuit-breakers with integral overcurrent protection for household and similar uses((RCBOs) stressed by surges, the unintended trip characteristics of RCBOs under surge currents were experimentally investigated using the combination wave generator. Seven different types of single-phase RCBOs being present on the domestic market were investigated according to KS C IEC 61009-1 standard. As a result, all kinds of specimens were satisfied the requirements for 0.5 [${\mu}s$]/100[kHz] ring wave impulse currents. Most of specimens stressed by the 8/20[${\mu}s$] impulse current tripped at least one or more, and some of them were broken down during consecutive tests. It was found that only one type of specimens meets the L-N mode immunity to the combination wave of 1.2/50[${\mu}s$] impulse voltage and 8/20[${\mu}s$] impulse current.

다중 뇌충격전류에 의한 산화아연형 피뢰기 소자의 특성 변화 (Characteristic Changes of ZnO Arrester Blocks by Multiple-lightning Impuse Currents)

  • 길경석;한주섭
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권12호
    • /
    • pp.685-690
    • /
    • 2000
  • Multiple-lightning impulse currents are a general feature of the lightning ground f=flash. It is therefore necessary for lightning arresters used in power systems to be estimated by applying not only a single-lightning impulse current but also a multiple-lightning impulse currents. This paper presents the effects of multiple-lightning impulse currents on deterioration of ZnO arrester blocks. The multiple-lightning impulse generator which can produce quadruple 8/20$[\mus]$ 5[kA] with separation time of 30~120[ms] is designed and fabricated. The total energy applied to the arrester block at each impulse is about 1,200[J]. In experiment, various parameters such as leakage current component, reference voltage, and temperature are measured with the number of applied impulse current. Also, micro-structure changes of the ZnO blocks after applying the single and the multiple-lightning impulse currents of 200 times are compared. The experimental results indicate that the types of arrester blocks are more vulnerable to deterioration or damage by multiple-lightning impulse currents.

  • PDF