펄스파 강도증가를 위한 피동제어 (Passive Control for the Augmentation of a Pulse Wave)

  • 이동훈;김희동;강성황
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.241-248
    • /
    • 2001
  • The present paper describes experimental and computational work to augment the magnitude of the impulsive wave. An experiment was performed using a simple shock tube with an open end and numerical calculations were carried out to solve the unsteady, axisymmetric, inviscid, compressible governing equations. The control strategy applied was to alter the exit geometry of a straight tube to a sudden enlargement tube and a flare tube. The effects of the configurations of the tube exit on the magnitude of the impulsive wave were investigated over the range of the weak shock Mach number from 1.01 to 1.10. The results obtained were compared to those of the straight tube tests. The numerical result predicted the magnitude of the experimented impulsive waves with a good accuracy. The present passive control technique enabled the magnitude of the impulsive wave to augment by about 23 percent, compared to that of the straight tube of no control.

  • PDF

Wave Patterns Due to a Point Impulse Travelling over Free Surface of Water of Finite Depth

  • Lee, G.J.;Chung, Y.K.
    • Journal of Hydrospace Technology
    • /
    • 제2권1호
    • /
    • pp.10-17
    • /
    • 1996
  • If a point impulse travels over free surface of water of finite depth, surface waves consist of divergent waves. The crestlines of those divergent waves are short and end on the cusp line if the impulse travels at a subcritical speed. But the crestlines become infinitely long and there are no cusps if the impulse travels at a supercritical speed.

  • PDF

SASW시험에 의한 위상속도 결정을 위한 임펄스 응답필터 기법 (Impulse Response Filtration Technique for the Determination of Phase Velocities from SASW Measurements)

  • 조성호
    • 한국지반공학회지:지반
    • /
    • 제13권1호
    • /
    • pp.111-122
    • /
    • 1997
  • 표면파를 이용하여 지반의 강성을 추정하는 기법인 SASW 시험에서 위상속도(phase volocity)를 결정하기 위해서는 위상각(phase angle)의 전개(unwrapping)가 필수적이다. 포장 구조에서처럼 깊이에 따라 강성의 차이가 현저한 경우는 기존의 위상각 전개방식으조는 정확한 위상속도를 결정하기가 용이하지 않다. 이는 기존의 위상각 전개방식은 주위상각(principal phase angle)에 2n의 정수배를 더하는 것인데, 위상각 스펙트럼(phase spectrum)에서 정수배를 결정하는 데에 어려움이 있기 때문이다. 본 연구에서는 이러한 문제점을 해결하기 위해서, 임펄스 응답 필터 기법(Impulse Response Filtration Technique), 또는 IRF기법이라고 하는 새로운 위상각 분석 기법을 제안하였다. IRF 기법의 원리는 임펄스 응답을 필터 처리함으로써 파군(wave group)을 분리하는 것인데,파군의 분리는 임펄스 응답에 대한 Gabor spectrogram을 분석한 정보를 근거로 한다. Gabor spectrogram은 전파되는 파의 에너지를 주파수-시간 공간에서 나타내는 contour 그림으로서, 파군의 전파 상황을 시각적으로 표현하는 수단이다. 이렇게 필터 처리된 임펄스 응답을 이용하면, 위상각 스펙트럼의 분석을 정확하게 할 수 있으며, 위상각의 전개에 있어서 난해함을 제거할 수 있다. 끝으로, 전쳔적인 포장 구조에 대하여 이론적으로 SASW 시험을 모사하였으며, 그 결과를 이용하여 IRF기법의 효용성을 입증하였다.

  • PDF

체적부하를 갖는 유체 전달관로의 압력전파 특성 (The Propagation Characteristics of the Pressure in the Volume Loaded Fluid Transmission Line)

  • 윤선주;손병진
    • 대한기계학회논문집
    • /
    • 제18권11호
    • /
    • pp.3075-3083
    • /
    • 1994
  • The applications of the electrical transmission line theory to the pressure propagation characteristics in the volume loaded fluid transmission line with step and impulse input wave is demonstrated in this paper. The method is based on the premise that the time response is the inverse Fourier transform of frequency spectrum of the wave which spectrum is a product of frequency spectrum of input pressure wave and system transfer function. The frequency response and transient response of step and impulse input wave in the volume loaded fluid transmission line is analysed by the Laplace transform and inverse Laplace transform with FFT numerical algorithm. The numerical solution of the distributed friction model is compared with the average friction model and the infinite product model. And the result is showed that FFT method may have major advantages for the simulation of fluid circuitary.

질량비 변화에 따른 산사태 모형으로 인해 생성되는 충격파의 특성분석 : 파진폭을 중심으로 (Analysis of Impulse Wave Characteristics Generated by Landslide Models with Various Mass Ratio : Focus on Wave Amplitude)

  • 조한울;이호진;김성덕
    • 한국지반환경공학회 논문집
    • /
    • 제24권4호
    • /
    • pp.5-11
    • /
    • 2023
  • 수역 인근에서 산사태로 인해 발생되는 충격파는 인명과 주변 기반시설에 치명적인 피해로 이어질 수 있다. 이러한 충격파는 일반적으로 산사태 충격파라고 하며, 특정지역에 국한되지 않고 발생한다. 최근에는 이상기후의 영향으로 국지성 집중호우가 빈번하게 발생하면서 국내에서 발생하는 산사태의 발생빈도와 발생규모 모두 증가하고 있다. 이에 본 연구에서는 산사태 모형의 질량비 변화에 따른 실험을 수행하였으며, 생성되는 충격파의 특성 중 파의 진폭을 중점으로 관측 및 분석하였다. 본 연구에서는 5가지의 산사태 모형의 질량비, 3가지의 수로경사로 15가지의 케이스에 대하여 5회 반복실험하여 총 75회의 실험을 수행하였다. 산사태 모형의 질량비를 달리하며 실험을 해본 결과, 만약 초기 에너지가 동일한 산사태의 경우 순수한 입상, 순수한 블록 형태의 산사태에 의해서 생성되는 충격파의 크기보다 입상형태와 블록형태가 섞여 함께 거동하며 생성하는 충격파의 크기가 더 클 수 있다고 분석된다.

2-D & 3-D Calculations for the Effect of Guide Vane of Impulse Turbine

  • Hyun Beom-Soo;MOON Jae-Seung;Hong Sung-Won
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.235-240
    • /
    • 2004
  • This paper deals with the performance analysis of impulse turbine for owe type wave energy conversion device. Numerical analysis was performed using a commercially-available software FLUENT. This parametric study includes the variation of the setting angle of guide vane. Since parametric study at various flaw coefficients requires tremendous amounts of computing time, two-dimensional cascade flaw approximation was employed to find out optimum principal particulars in rather simple manner. Full three-dimensional calculation was also performed for several cases to confirm the validity of two-dimensional approach. Results were compared to other experimental data, for instance Setoguchi et al (2001)'s extensive set of data, and found to be well demonstrating the usefulness of 2-D analysis. Advantages and disadvantages of each method were also evaluated.

  • PDF

Performance Prediction of Impulse Turbine System in Various Operating Conditions

  • 현범수
    • 한국해양공학회지
    • /
    • 제21권5호
    • /
    • pp.9-17
    • /
    • 2007
  • This paper deals with the design and analysis of a 250kW class impulse turbine for wave energy conversion. Numerical analysis was performed using FLUENT. The size and the performance of a turbine required to provide a certain power can be estimated using a series of performance charts built through the present study. Temporal and spatial variations of flaw fields were also considered and compared with those of uniform inflow. It was concluded that a simple steady-flow analysis using performance charts still provided a practical and useful way to predict the design and performance of turbines.

Numerical Study on Frequency Up-conversion in USPR using MATLAB

  • Roh, Young-Su
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.497-502
    • /
    • 2010
  • In this paper, the O-mode ultrashort-pulse reflectometry (USPR) millimeter-wave signals that propagate into the plasma and cover a frequency bandwidth of 33-158 GHz are examined numerically using MATLAB. Two important processes are involved in the computation: the propagation of the USPR impulse signal through a waveguide and the frequency up-conversion using millimeter-wave mixers. These mixers are limited to intermediate frequency signals that are less than 500 mV; thus, it is necessary to disperse the impulse signal into a chirped waveform using the waveguide. The stationary phase method is utilized to derive a closed-form formula for a chirped waveform under the assumption that the USPR impulse is Gaussian. In the process of frequency up-conversion, the chirped waveform is mixed with the mixer LO signal, and the lower frequency components of the RF signal are removed using high pass filters.

$SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성 (V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages)

  • 이복희;이경옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF